A Latching relay: Used for call registration,direction selection or as selector relays
Two types are: Set/Rest are electrical and Mechanical Latching relays
Need to know latching relay symbol, Its a box with shaded triangle in lower right hand corner. -
answer Which relay do you need to Order
710 Pg, 7
RPM = 60 ∙ ƒ ÷ P÷2 =
Step 1. 60 x Frequency (Hz.)
= Step 2. Poles ÷ 2 =
Take answer 1 and ÷ by answer 2 = - answer Know the formula for
RPM 435 Pg. 5
If you are referring to a megohm meter, it is a test of the insulation properties of such things as
electric wiring, motor windings and high power antenna mounts.
We use a "megger" or "meg out" electrical wiring and equipment to see if it is shorted to ground
or the frame in any way.
The megger uses much higher voltages to check resistance than a normal Volt-ohm meter.
Minimum resistance is 1 Meg Ohm - answer Know what a Megger is and what it does
636 Pg. 13
(1) A parallel connection. (2) A resistive element placed across the terminals of an armature to
bypass a portion of the current. (3) A flexible electrical conductor designed to conduct current
around the mechanical joint between two conductors. (4) The resistive element (Usually of very
low resistance) used in parallel with a DC ammeter movement to bypass a calibrated portion of
the total circuit current. - answer Shunt Overloads
425 All Pages
Bad Ground - answer You are using a Temp Run Box and you get shocked!
Why! 520 Pg. 4
The bridle hitch can consist of two,three, or four single hitches (fig. 3-22), used together to
form a bridle hitch for hoisting an object
A sling with two legs used to lift a 1,000 pound object will have 500 pounds of the load on each
leg when the sling angle is 90 degrees. The load stress on each leg increases as the angle
decreases; and if the sling angle was 30 degrees lifting the same 1,000 pound object, the load
will be 1,000 pounds on each leg. Try to keep all sling angles greater than 45 degrees; sling
angles approaching
, www.stuvia.com/user/AcademicACHIEVER
30 degrees are considered extremely hazardous and must be avoided at all cost. - answer
Bridal Hitch
128 Pg 17
Scaffolding should be tied to the structure using
#9 wire or tie-in devices. The first vertical tie
should be at the maximum height of 4 times the
narrowest base dimension. Additional ties are
not to exceed 26' vertically. Maximum horizontal
distance between ties is not to exceed 30'. - answer Scaffolding, You have 32' of rise, you are
using 3x5 scaffolding. Where will the tie off points be ?
140 PG. 287-288
Counterweights (Typically) are hung to counter balance the weight of the car PLUS 40% of
Capacity Load. - answer How much should Counterweight way?
240 Pg. 14
Note: We do not use wire smaller than #20 in travelling cables and #24 outside
travelers. Largest wires are feeders to Hoist /Pump motor
We always have 10 %
spares 10% of 52 = 5.2
On a calculator Multiply the percent 10 by the number you have and ÷ by
100 10 X 52 ÷ 100 = 5.2 - answer Pulling Spare Wires (Example) 10% of 52
Wires
515 Pg.26
The correct lube must be used on chains. - answer The freight door motor is spinning but the
door wont move, Why?
535 Pg. 9
Lula: Limited use/Limited Access (Example Wheelchair
Lifts) Max Rise 25'
Max Speed 30 Ft/Min
Max Capacity 1400
Lbs.