Questions and Answers Latest
Updated 2025/2026 (Graded A+)
When fire is exposing a windowless type I or type II building where should
the first hose
line be placed? - ANSWER- Inside the fire
building.
Rule of thumb for collapse anticipation in ordinary construction or wood
frame buildings
is that if the fire was heavily involved for_________ minutes, fire forces
should be
withdrawn. - ANSWER-
20
Size Up C - ANSWER- Construction
Size Up O - ANSWER- Occupancy
Size Up A - ANSWER- Apparatus and staffing OR building area (size) OR
auxiliary
applianc
es
Size Up L - ANSWER- life hazards
Size Up W - ANSWER- Water supply or weather
Size Up S - ANSWER- Street conditions /
Size Up E - ANSWER- Exposures
Size Up L - ANSWER- Location and extent of the fire
Size Up T - ANSWER- Time
Size Up H - ANSWER- Hazardous materials involved
Statistics are shown the greatest civilian life hazard occurs in
which occupancy? -
ANSWER- Residential
buildings
As far as construction effects size up, a fire involving a newer metal
deck roof generally
does what to fire load - ANSWER-
Increases it.
Fire Tactics
, Which classic construction is most resistant to collapse caused by fire?
Consider building type and older or newer. - ANSWER- Older type class I.
Knew her type class I may be considered "lightweight" class I construction.
A cellar fire in a fireproof building, a top floor fire in a frame apartment
complex, fire on the second floor of a three-story windowless warehouse, all
of these present what? - ANSWER- Special firefighting problems.
What is the required fire flow for a private home in GPM per 100
square feet? -
ANSWER-
15
What is the required fire flow for a commercial building in GPM per
100 square feet? -
ANSWER-
35
What is the required fire flow for an industrial building in GPM per
100 square feet? -
ANSWER-
60
Name a type of auxiliary appliance. - ANSWER- Anything that is part
of a built-in fire
suppression
system.
What construction factor is responsible for the destruction of more
buildings than any
other? - ANSWER- The presence of
hidden voids.
True or false: hose streams may be used for all of the following purposes. Fire
extinguishment. Exposure protection. Controlled burning. Forced ventilation
of gases.
Absorbing toxic fumes. - ANSWER- TRUE
What is the most important reason for selecting the combination
attack method on a
fire? - ANSWER- It puts firefighters in the best position to
save lives.
The method of attack best suited for the free burning stage is: - ANSWER-
Combination
attac
k
The three strategic options in firefighting are: - ANSWER- All offensive,
defensive, no
actio
n.
While commanding an attack line you find the line is unable to advance
into the fire area
Fire Tactics