1 - Scope 1-Which of the following activities is NOT included in the scope of API 570? - correct answers Operating a pipe system 2-Which of the following activities is NOT included in the scope of API 570? - correct answers Performing pipe fabrication 3-API 570 pertains to: - correct answers Only to metallic and FRP pipe 4-API 570 pertains only to: - correct answers Pipe and their associated relief devices 5-The inspector discovers a problem on a pipe that requires corrective action. Who is responsible to respond to this issue? - correct answers Owner/User 6-API 570 is used: - correct answers By petro-chemical facilities 7-API 570 takes effect: - correct answers Once the pipe is places in service 8-Companies that use API 570 must: - correct answers Either employ or have access to an authorized inspection agency 9-During a piping repair, if there is a conflict between the requirements of API 570 and the construction code, which should be followed? - correct answers API 570 10-Duringa piping alteration, if there is a conflict between the requirements of API 570 and the construction code, which should be followed? - correct answers API 570 11-An in-service pipe in being repaired or altered. If there is a conflict between the requirements of API 570 and the legal jurisdiction, which should be followed? - correct answers The most stringent requirements 12-An in-service piping system is inspected. If there is a conflict between the requirements of API 570 and the legal jurisdiction, which should be followed? - correct answers The most stringent requirements 13-The requirements of API 570 are considered optional for which of the following piping systems? - correct answers 300 psig steam system 14-The requirements of API 570 are considered optional for which of the following piping systems? - correct answers Category D piping 15-Which of the following chemical plant piping is NOT included in the scope of API 570? - correct answers 4 NPS low-density polyethylene pipe 16-Which code is used for Fitness for Service evaluations? - correct answers API 579 17-Which code is used for RBI evaluations? - correct answers API 580 Section 2 1-During an in-service internal inspection, a crack is discovered on a longitudinal weld. This crack can be evaluated to which code? - correct answers API 579 2-Which code provides requirements for hot tapping? - correct answers API 2201 3-Which publication provides information on corrosion mechanisms? - correct answers API 571 4-Which publication is used for RBI assessments? - correct answers API 580 5-Which recommended practice is used for guidance in inspecting and testing valves? - correct answers API 578 **6-Which document can be used when determining soil resistivity? - correct answers ASTM G57 **7-Which document can provide more information on Injectionmand Mixing points? - correct answers NACE RP 34101 Section 3 1-Which of the following is considered a piping alteration? - correct answers Replacement 4 NPS portion of a line with a 6 NPS section 2-An alteration on a piping system is defined as: - correct answers Any physical change with design implications 3-Which of the following inspection organizations is NOT considered an acceptable API 570 Authorized Inspection Agency? - correct answers Piping fabricator 4-Which of the following is considered an API 570 Authorized Inspection Agency? - correct answers The inspection organization of the jurisdiction 5-A CML is: - correct answers A point or plane through the pipe 6-A critical check valve is one that: - correct answers Could cause a hazardous event (like Boom!) if it fails 7-A defect is defined as: - correct answers A discontinuity that exceeds the applicable code's criteria 8-What is maximum diameter of an examination point on an 8 NPS line? - correct answers 2" 9-What is maximum diameter of an examination point on a 12 NPS line? - correct answers 3" 10-An imperfection is: - correct answers Defined as a flaw 11-An indication is: - correct answers A response from an NDE examine 12-An injection point does NOT include: - correct answers Process mix points 13-What is an integrity operating envelope? - correct answers Key process limits that are set because of a potential degradation mechanism 14-What is management of change? - correct answers Term used to describe a documented system to review process changes 15-What is a mixing point? - correct answers A piping component that combines two process streams of differing composition 16-Off-site piping is: - correct answers Piping in a plant that us not in a process unit 17-A piping circuit: - correct answers Is piping of similar metallurgy that is exposed to same process envoirment 18-The purpose of PMI is to determine: - correct answers That piping components are specified materials 19-Pressure design thickness: - correct answers Considers only design pressure and design pressure and design temperature 20-A piping repair is defined as: - correct answers The work necessary to restore a piping system to a suitable safe condition 21-A propane 4 NPS line has experience damage by CUI. About 150 ft will be replaced during the next turnaround. Which of the following is true? - correct answers This work is considered a repair 22-Which of the following inspection oranizations is NOT considered an acceptable API 570 Repair Organization? - correct answers The governing jurisdiction based on the location of the piping system 23-Which of the following is NOT considered a piping rerate? - correct answers Increased the fluid viscosity 24-Secondary process piping is defined as pipe that is: - correct answers Downstream of normally closed block valves 25-Small bore piping is defined as pipe: - correct answers Less than or equal 2 NPS 26-The soil-to-air zone is considered to be: - correct answers 6 inches above the interface and 12 below the interface Section 4 1-Who is responsible to ensure that all the requirements of API 570 are met? - correct answers Owner/User 2-Who is responsible to ensure that the Authorized Inspection Agency functions in accordance with the requirements or API 570? - correct answers Owner/User 3-An integrity operating window is - correct answers A list of process process parameters that could affect equipment integrity 4-Which of the following are integrity operating envelopes? - correct answers Process parameters like velocity, ph, temperature, flow rate 5-Each owner/user that uses API 570 must: - correct answers Maintain a quality assurance inspection/repair management system 6-Which of the following is NOT required to be in the owner/user's quality assurance inspection/repair management system? - correct answers Establish vacation policy for authorized inspectors 7-Who is responsible for implementing an effecting Management of Change process? - correct answers Owner/User 8-A MOC system should be used to review and control changes to: - correct answers Either the process or the hardware 9-When repairs and alterations are being conducted, which individual or organization is responsible for Quality Control? - correct answers Repair Organization 10-Which of the following is NOT a role for the API 570 inspector? - correct answers Provide the Owner assurance that all welding meet requirements 11-During in-service piping repairs, all examination results must be accepted by the: - correct answers Authorized inspector 12-Which do the following is a role for the API 570 inspector? - correct answers Evaluate and accept NDE results 13-Who is responsible to maintain the certification records for NDE examiners? - correct answers Examiner's employer 14-When unusual operating conditions occur on a piping system, e.g. upset conditions, operations personnel should inform: - correct answers Either the inspector or engineer Section 5 1-All in-service piping in the petrochemical industry must: - correct answers Have an inspection plan 2-The inspection plan doe a piping system should be developed by: - correct answers Either the inspector or the engineer 3-When developing a piping system's inspection plan, who should identify specific damage mechanisms and their locations? - correct answers Corrosion specialist 4-Whose input is required when developing an inspection plan that operates at an elevated temperature? - correct answers Corrosion specialist 5-A corriosion specialist shouldbe consulted when developing inspection plans for piping that operates above: - correct answers 750 degrees F 6-Which of the following is NOT required in a piping systems's Inspection plan? - correct answers Name of individual that will perform the inspection 7-All RBI assessments must be conducted in accordance with: - correct answers API 580 8-In the RBI process, what are the two primary factors used to determine risk? - correct answers Probablitily and consequences of Failure 9-Who authorizes the use of RBI assessments to set inspection intervals? - correct answers Owner/User 10-During a risk assessment, which of the following factors does NOT increase the probability of failure? - correct answers Volume of release 11-During a risk assessment, which of the following factors most factors most affects the consequence of failure? - correct answers Type and amount of process fluid 12-Which of the following is NOT a significant factor in an RBI assessment of a piping system? - correct answers Piping construction code 13-During an RBI assessment of a piping system, which of the following is NOT a significant factor that is considered to the analysis of the Consequence of Failure? - correct answers Public image 14-All RBI assessments must be: - correct answers Thoroughly documented 15-If RBI assessments are used to intervals, the assessment shall be repeated: - correct answers Every 5 years 16-If RBI assessments are used to set intervals, the assessment shall be repeated: - correct answers After each significant process or hardware change 17-All NDE equipment used in petrochemical facilities must: - correct answers Have a safety rating appropriate for the gaseous envoirment at the exam site 18-Which of the following is NOT a requirement prior to performing an inspection? - correct answers Be certified as an ASNT SNT-TC-1A Level 2 in VT 19-If a pipe is large enough for an internal inspection . The internal inspection should meet the requirements of: - correct answers API 510 20-Who is responsible to perform the on-stream inspection of a piping system? - correct answers Authorized inspector or an examiner 21-When UT thickness measurements are taken: - correct answers The owner must assure competency of those taking the readings 22-UT thickness measurements may be performed by the: - correct answers Authorized inspector or the examiner

Meer zien Lees minder
Instelling
API 570
Vak
API 570

Voorbeeld van de inhoud

API 570 test questions and answers
solutions guaranteed

1 - Scope

1-Which of the following activities is NOT included in the scope of API 570? - correct answers Operating
a pipe system



2-Which of the following activities is NOT included in the scope of API 570? - correct answers Performing
pipe fabrication



3-API 570 pertains to: - correct answers Only to metallic and FRP pipe



4-API 570 pertains only to: - correct answers Pipe and their associated relief devices



5-The inspector discovers a problem on a pipe that requires corrective action. Who is responsible to
respond to this issue? - correct answers Owner/User



6-API 570 is used: - correct answers By petro-chemical facilities



7-API 570 takes effect: - correct answers Once the pipe is places in service



8-Companies that use API 570 must: - correct answers Either employ or have access to an authorized
inspection agency



9-During a piping repair, if there is a conflict between the requirements of API 570 and the construction
code, which should be followed? - correct answers API 570

,10-Duringa piping alteration, if there is a conflict between the requirements of API 570 and the
construction code, which should be followed? - correct answers API 570



11-An in-service pipe in being repaired or altered. If there is a conflict between the requirements of API
570 and the legal jurisdiction, which should be followed? - correct answers The most stringent
requirements



12-An in-service piping system is inspected. If there is a conflict between the requirements of API 570
and the legal jurisdiction, which should be followed? - correct answers The most stringent requirements



13-The requirements of API 570 are considered optional for which of the following piping systems? -
correct answers 300 psig steam system



14-The requirements of API 570 are considered optional for which of the following piping systems? -
correct answers Category D piping



15-Which of the following chemical plant piping is NOT included in the scope of API 570? - correct
answers 4 NPS low-density polyethylene pipe



16-Which code is used for Fitness for Service evaluations? - correct answers API 579



17-Which code is used for RBI evaluations? - correct answers API 580



Section 2

1-During an in-service internal inspection, a crack is discovered on a longitudinal weld. This crack can be
evaluated to which code? - correct answers API 579



2-Which code provides requirements for hot tapping? - correct answers API 2201



3-Which publication provides information on corrosion mechanisms? - correct answers API 571



4-Which publication is used for RBI assessments? - correct answers API 580

,5-Which recommended practice is used for guidance in inspecting and testing valves? - correct answers
API 578



**6-Which document can be used when determining soil resistivity? - correct answers ASTM G57



**7-Which document can provide more information on Injectionmand Mixing points? - correct answers
NACE RP 34101



Section 3

1-Which of the following is considered a piping alteration? - correct answers Replacement 4 NPS portion
of a line with a 6 NPS section



2-An alteration on a piping system is defined as: - correct answers Any physical change with design
implications



3-Which of the following inspection organizations is NOT considered an acceptable API 570 Authorized
Inspection Agency? - correct answers Piping fabricator



4-Which of the following is considered an API 570 Authorized Inspection Agency? - correct answers The
inspection organization of the jurisdiction



5-A CML is: - correct answers A point or plane through the pipe



6-A critical check valve is one that: - correct answers Could cause a hazardous event (like Boom!) if it
fails



7-A defect is defined as: - correct answers A discontinuity that exceeds the applicable code's criteria



8-What is maximum diameter of an examination point on an 8 NPS line? - correct answers 2"

, 9-What is maximum diameter of an examination point on a 12 NPS line? - correct answers 3"



10-An imperfection is: - correct answers Defined as a flaw



11-An indication is: - correct answers A response from an NDE examine



12-An injection point does NOT include: - correct answers Process mix points



13-What is an integrity operating envelope? - correct answers Key process limits that are set because of
a potential degradation mechanism



14-What is management of change? - correct answers Term used to describe a documented system to
review process changes



15-What is a mixing point? - correct answers A piping component that combines two process streams of
differing composition



16-Off-site piping is: - correct answers Piping in a plant that us not in a process unit



17-A piping circuit: - correct answers Is piping of similar metallurgy that is exposed to same process
envoirment



18-The purpose of PMI is to determine: - correct answers That piping components are specified
materials



19-Pressure design thickness: - correct answers Considers only design pressure and design pressure and
design temperature



20-A piping repair is defined as: - correct answers The work necessary to restore a piping system to a
suitable safe condition

Geschreven voor

Instelling
API 570
Vak
API 570

Documentinformatie

Geüpload op
17 april 2026
Aantal pagina's
33
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.59
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
RealGrades Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
188
Lid sinds
2 jaar
Aantal volgers
52
Documenten
12093
Laatst verkocht
3 dagen geleden

4.0

26 beoordelingen

5
12
4
5
3
7
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen