What is the standard polarity of a 14.4 transformer that is less than 200 kVA? -
ANSWER ✓ Subtractive
Explain the properties that describe a good insulator. - ANSWER ✓ An object
with few free electrons
What is the purpose of equipotential bonding (grounding) - ANSWER ✓ Allow
worker to be bonded to ground, giving him the equal potential to ground. ???
Describe the proper procedure and order of protective ground installation -
ANSWER ✓ -Arrange for isolation certification of the circuit, choose grounding
location, determine proper grounding cable size most effective for ground
electrode, establish a bonding work zone, test circuit to be grounded to verify
isolation, install ground clip on phase conductors
In what order must the protective grounds be removed from the line - ANSWER
✓ In reverse order
Define step potential - ANSWER ✓ Voltage difference between feet of the person
near energized grounded object
Define touch potential - ANSWER ✓ The voltage between any two points on a
person's body
, Define second point of contact - ANSWER ✓ 2 exposed objects in your
immediate area you can come into contact with
Online work reports are due on the _____ of every month. No later than the
_______ - ANSWER ✓ 1st, 5th
The probationary period is the first _____ hours of your apprenticeship -
ANSWER ✓ 1750
To complete each school year, you must have an average test score of _______
percent at the end of every year - ANSWER ✓ 80
to complete the apprenticeship, you must have _______ regular hours and
_______ hot hours worked - ANSWER ✓ 7000, 650
To complete the program, you must take the 5 state exam. On that exam, there are
3 written parts and 1 practical part. The written requires a score of _____ to pass -
ANSWER ✓ 75
your workbook lessons are due on the _______ before class by _______ Pm
mountain time - ANSWER ✓ Wed. , 10
If you quit your job or are fired, you will immediately be _____ and can no longer
work until seen at a subcommittee meeting - ANSWER ✓ Suspended
MSLCAT stands for ___________ - ANSWER ✓ Mountain states line
construction joint apprenticeship and training committee
cold apprentices can only work on live equipment live less than _______ volts -
ANSWER ✓ 500
To advance to the next step you will need both ____ hours and _____ months in
time - ANSWER ✓ 1000, 6
A $_______ weekly tuition payroll deduction will be due for each week of the
apprenticeship - ANSWER ✓ 30
, It is the _______ responsibility to monitor and maintain current certifications -
ANSWER ✓ apprentices
There are two reasons you could miss class - ANSWER ✓ - storm work
-death in immediate family
The director may ask for wages paid for the past _______ months - ANSWER ✓
6
Whose responsibility is it to maintain a clean, healthy, and orderly workplace? -
ANSWER ✓ Every employer
Linework is considered to be a ______ - ANSWER ✓ High-risk job
Risk= __________x__________x____________ - ANSWER ✓ consequences,
exposure, probability
Define: Consequences - ANSWER ✓ Damage or injures caused when accidents
occur
Define Exposure - ANSWER ✓ The time a person is within a hazardous area
Define Probability - ANSWER ✓ Likely hood of making contact with a hazard
Risk is reduced for lineman by using _____ that will lower the probability of the
________ - ANSWER ✓ Barriers(safety equipment), Contact/hazard
T or F. Removing the hazard or placing a barrier between the hazard and the
workers will reduce the probability of contact - ANSWER ✓ True
4 rules of the use of rubber gloves as PPE and their Definition - ANSWER ✓ 1.
Ground to Ground- Rubber gloves should be worn continuously while working on
any structure carrying energized conductors
2. Cradle to Cradle- Rubber Gloves shall be worn from the time a bucket truck
boom leaves its cradle to the time it returns
3. Extended reach rule- Rubber gloves shall be worn on a worker and any non-
insulated tools being used are able to contact energized conductor (extended reach