SC LP Gas Reseller EXAM STUDY GUIDE 2026/2027 COMPLETE QUESTIONS WITH VERIFIED CORRECT ANSWERS || 100% GUARANTEED PASS NEWEST VERSION 1. Other than a Deputy State Fire Marshal of the Division of State Fire Marshal, who may be permitted to enter during reasonable business hours to inspect your gas industry to assure the safety of the public? - ANSWER A member of the LP Gas Board 2. South Carolina's laws regarding the retail sale of propane to the public require that the seller have a license from the LP Gas Board and...? - ANSWER An individual certified as competent by the Division of State Fire Marshal 3. According to the National Fire Protection Association Pamphlet (NFPA) #58, what is the limit on a temporary installation? - ANSWER Not to exceed 6 months from the date of installation 4. The ratio of Ethyl Mercaptan per 10,000 gallons of LP Gas by test shall be how many lbs. per gallon? - ANSWER 1.0 lbs. per 10,000 gallons of LP Gas 5. DOT containers shall be designed, fabricated, tested, and marked (or stamped) in accordance with which organization? - ANSWER U.S. Department of Transportation 6. Containers for general use shall not have individual water capacities greater than how many gallons? - ANSWER 120,000 water gallons 7. Service station containers shall not have individual capacities greater than how many gallons? - ANSWER 30,000 water gallons 8. In buildings under construction or repair, the total water capacity of containers manifold together and serving any one heater shall not be greater than what capacity? - ANSWER 735 pounds 9. In buildings undergoing minor renovations and visited by the public during normal work hours, what is the maximum capacity of LP Gas that can be present in this building? - ANSWER A 20 lb. container per worker assigned to use LP Gas 10. The use of LP Gas in buildings for demonstration and/or training is limited to a maximum water capacity of 5 pounds. If more than one such container is used in classrooms, how much distance shall you have between containers? - ANSWER 20 feet 11. The maximum LP Gas water capacity container that can be connected to any one manifold at a single permanent installation located on a roof and using portable containers is what? - ANSWER 400 lbs. 12. All installations of LP Gas on roofs of buildings must be reported to what agency? - ANSWER Local Fire Department 13. The maximum water capacity of a fuel container of LP Gas on an individual forklift shall not exceed how many lbs? - ANSWER 105 lbs. 14. To store or service a vehicle powered by LP Gas inside a building, what must be accomplished? - ANSWER The fuel system must be leak free 15. Smoking, open flames, metal cutting or welding, portable electrical tools and extension lights capable of igniting LP Gas shall not be permitted within what distance from an ASME container? - ANSWER 15 feet from point of transfer 16. Indoor gas hose connector requirements - ANSWER Indoor gas hose connectors shall be used only to connect laboratory, shop, and ironing appliances requiring mobility during operation. 17. Outdoor gas hose connector requirements - ANSWER Where outdoor gas hose connectors are used to connect portable outdoor appliances, the connector shall be listed in accordance with ANSI Z21.54. 18. Flexible connection requirements - ANSWER Where flexible connections are used, they shall be of the minimum practical length and shall not extend from one room to another. 19. Manual shutoff valve requirement - ANSWER Each appliance connected to a piping system shall have an accessible, approved manual shutoff valve with a non-displaceable valve member. 20. Location of shutoff valve - ANSWER The shutoff valve shall be located within 6 feet of the appliance it serves. 21. Gas convenience outlet requirements - ANSWER Gas convenience outlets shall be listed in accordance with ANSI Z21.90/CSA 6.24 and installed in accordance with the manufacturer's installation instructions. 22. Sediment trap installation - ANSWER Where a sediment trap is not incorporated as a part of the appliance, a sediment trap shall be installed as close to the inlet of the appliance as practicable. 23. Central heating furnace installation in bedrooms - ANSWER Central heating furnaces and low-pressure boilers shall be installed in a closet equipped with a weather-stripped door with no openings. 24. Central heating furnace installation requirements - ANSWER Shall comply with specific conditions including installation in a closet with a weather-stripped door and self-closing device. 25. Direct vent type boilers - ANSWER Central heating furnaces and low pressure boilers shall be of the direct vent type.

Show more Read less
Institution
LP Gas Master Qualifier
Course
LP Gas Master Qualifier

Content preview

SC LP Gas Reseller EXAM STUDY
GUIDE 2026/2027 COMPLETE
QUESTIONS WITH VERIFIED CORRECT
ANSWERS || 100% GUARANTEED PASS
<NEWEST VERSION>



1. Other than a Deputy State Fire Marshal of the Division of State Fire
Marshal, who may be permitted to enter during reasonable business hours to
inspect your gas industry to assure the safety of the public? - ANSWER ✔ A
member of the LP Gas Board


2. South Carolina's laws regarding the retail sale of propane to the public
require that the seller have a license from the LP Gas Board and...? -
ANSWER ✔ An individual certified as competent by the Division of State
Fire Marshal


3. According to the National Fire Protection Association Pamphlet (NFPA)
#58, what is the limit on a temporary installation? - ANSWER ✔ Not to
exceed 6 months from the date of installation


4. The ratio of Ethyl Mercaptan per 10,000 gallons of LP Gas by test shall be
how many lbs. per gallon? - ANSWER ✔ 1.0 lbs. per 10,000 gallons of LP-
Gas

,5. DOT containers shall be designed, fabricated, tested, and marked (or
stamped) in accordance with which organization? - ANSWER ✔ U.S.
Department of Transportation


6. Containers for general use shall not have individual water capacities greater
than how many gallons? - ANSWER ✔ 120,000 water gallons


7. Service station containers shall not have individual capacities greater than
how many gallons? - ANSWER ✔ 30,000 water gallons


8. In buildings under construction or repair, the total water capacity of
containers manifold together and serving any one heater shall not be greater
than what capacity? - ANSWER ✔ 735 pounds


9. In buildings undergoing minor renovations and visited by the public during
normal work hours, what is the maximum capacity of LP Gas that can be
present in this building? - ANSWER ✔ A 20 lb. container per worker
assigned to use LP Gas


10.The use of LP Gas in buildings for demonstration and/or training is limited
to a maximum water capacity of 5 pounds. If more than one such container
is used in classrooms, how much distance shall you have between
containers? - ANSWER ✔ 20 feet


11.The maximum LP Gas water capacity container that can be connected to any
one manifold at a single permanent installation located on a roof and using
portable containers is what? - ANSWER ✔ 400 lbs.

,12.All installations of LP Gas on roofs of buildings must be reported to what
agency? - ANSWER ✔ Local Fire Department


13.The maximum water capacity of a fuel container of LP Gas on an individual
forklift shall not exceed how many lbs? - ANSWER ✔ 105 lbs.


14.To store or service a vehicle powered by LP Gas inside a building, what
must be accomplished? - ANSWER ✔ The fuel system must be leak free


15.Smoking, open flames, metal cutting or welding, portable electrical tools and
extension lights capable of igniting LP Gas shall not be permitted within
what distance from an ASME container? - ANSWER ✔ 15 feet from point
of transfer


16.Indoor gas hose connector requirements - ANSWER ✔ Indoor gas hose
connectors shall be used only to connect laboratory, shop, and ironing
appliances requiring mobility during operation.


17.Outdoor gas hose connector requirements - ANSWER ✔ Where outdoor gas
hose connectors are used to connect portable outdoor appliances, the
connector shall be listed in accordance with ANSI Z21.54.


18.Flexible connection requirements - ANSWER ✔ Where flexible connections
are used, they shall be of the minimum practical length and shall not extend
from one room to another.

, 19.Manual shutoff valve requirement - ANSWER ✔ Each appliance connected
to a piping system shall have an accessible, approved manual shutoff valve
with a non-displaceable valve member.


20.Location of shutoff valve - ANSWER ✔ The shutoff valve shall be located
within 6 feet of the appliance it serves.


21.Gas convenience outlet requirements - ANSWER ✔ Gas convenience outlets
shall be listed in accordance with ANSI Z21.90/CSA 6.24 and installed in
accordance with the manufacturer's installation instructions.


22.Sediment trap installation - ANSWER ✔ Where a sediment trap is not
incorporated as a part of the appliance, a sediment trap shall be installed as
close to the inlet of the appliance as practicable.


23.Central heating furnace installation in bedrooms - ANSWER ✔ Central
heating furnaces and low-pressure boilers shall be installed in a closet
equipped with a weather-stripped door with no openings.


24.Central heating furnace installation requirements - ANSWER ✔ Shall
comply with specific conditions including installation in a closet with a
weather-stripped door and self-closing device.


25.Direct vent type boilers - ANSWER ✔ Central heating furnaces and low-
pressure boilers shall be of the direct vent type.

Written for

Institution
LP Gas Master Qualifier
Course
LP Gas Master Qualifier

Document information

Uploaded on
April 20, 2026
Number of pages
54
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProfBenjamin Havard School
Follow You need to be logged in order to follow users or courses
Sold
660
Member since
1 year
Number of followers
17
Documents
3911
Last sold
22 hours ago
EXCELLENT ACHIEVERS LIBRARY

As a professional tutor, I provide exceptional assistance with homework, quizzes, and exams across various subjects, including Psychology, Nursing, Biological Sciences, Business, Engineering, Human Resource Management, and Mathematics. I am dedicated to offering high-quality support and ensuring that all work meets scholarly standards. To enhance the effectiveness of our services, I work with a team of experienced tutors to create comprehensive and effective revision materials. Together, we are committed to helping students achieve excellent grades through our collaborative efforts and expertise.

Read more Read less
3.8

135 reviews

5
63
4
18
3
33
2
9
1
12

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions