Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

UTAH BURGLAR ALARM QUALIFYING AGENT QUESTIONS AND ANSWERS EXAM 2026

Beoordeling
-
Verkocht
-
Pagina's
7
Cijfer
A+
Geüpload op
21-04-2026
Geschreven in
2025/2026

Alarm Alarm UTAH BURGLAR ALARM QUALIFYING AGENT QUESTIONS AND ANSWERS EXAM 2026 UL Standard for intrusion detectors - ANSWER-639 UL Standard for connectors and switches - ANSWER-634 When installing NC door contacts (open on alarm), the EOL resistor should be placed - ANSWER-In series at device When installing NO door contacts (short on alarm), the EOL resistor should be placed - ANSWER-In parallel at device A motion detector that uses a transmit frequency of 20 to 40 KHz is referred to as a: - ANSWER-Ultrasonic detector A motion detector that uses a transmit frequency of 10-20 GHz is referred to as a: - ANSWER-Microwave detector PIRs transmit on a frequency of 100-200 KHz. T or F - ANSWER-False T or F? PIRs are most sensitive to motion toward and away from the detector. - ANSWER-False T or F? Microwave detectors are most sensitive to motion toward and away from the detector. - ANSWER-True Biased magnetic contacts are used for - ANSWER-High security applications T or F? Microwave detectors can penetrate glass, wood paneling and Sheetrock. - ANSWER-True T or F? Dual technology motion detectors are used to reduce false alarms. - ANSWER True T or F? PIRs utilize the Doppler shift principle to detect motion. - ANSWER-False Why are reed contacts are plated with rhodium or similar materials? - ANSWER-To prevent welding What is the National Electric Code? - ANSWER-NFPA 70 Alarm Alarm What is the National Fire Alarm Code? - ANSWER-NFPA 72 Which UL standard covers the installation of burglar alarms? - ANSWER-681 What does the ANSI/SIA OSIPS DVI standard cover? - ANSWER-Video and ip related interface TIA/EIA 568 standard relates to: - ANSWER-Structured wiring Who has final say on fire alarm system installation? - ANSWER-AHJ T or F? Since ADA is a law, it has no effect on Codes. - ANSWER-False T or F? Codes and Standards both have the same meaning. - ANSWER-False Which standard is referred to as the Control Panel Standard, Features for False Alarm Reduction? - ANSWER-ANSI/SIA CP-01-2007 T or F? ANSI is a leading standards developer in the United States. - ANSWER-False T or F? ISO is the worlds largest developer and publisher of international standards. - ANSWER-True T or F? ISO 9000 describes the fundamentals of quality management systems. - ANSWER-True Which standard is referred to as the Digital Communication Standard, Internet Protocol Event Reporting? - ANSWER-ANSI/SIA DC-09-2007 Which UL Standard is for Central Station Automation Systems? - ANSWER-1981 Which UL Standard covers Police Station Connected Burglar Alarm Units and Systems? - ANSWER-365 Which UL Standard covers Central-Station Burglar-Alarm Systems? - ANSWER-611 What is the National Life Safety Code? - ANSWER-NFPA 101 A technique for allocating IP addresses dynamically so that the addresses can be reused when the host no longer needs them is called - ANSWER-DHCP CDPD is a type of - ANSWER-Cellular communicator 1400 Hz, 2300 Hz, and Dual tone are used as.. - ANSWER-Digital communicator handshake Alarm Alarm The hardware address of a device connected to a network is called its - ANSWER-MAC address Is a broadband connection required for internet monitoring? - ANSWER-Yes Can long range radio systems meet UL requirements for line security? - ANSWER-Yes DSL, Cable modems, and Satellite modems can be used to provide: - ANSWER Internet monitoring Can 2-way voice monitoring be used to reduce false alarms? - ANSWER-Yes Does VOIP have an effect on digital Alarm communicators? - ANSWER-Yes Which type of jack should be used to connect a digital communicator? - ANSWER-Rj 31x Which type of jack should be used to connect an internet communicator? - ANSWER Rj-45 T or F? In order to use the internet for monitoring, the control panel must be designed specifically for data communications. - ANSWER-False 4/2, SIA, and Contact ID are examples of: - ANSWER-Digital communicator format T or F? Remote video can be used to reduce false alarm dispatches. - ANSWER-True T or F? A burglar alarm system with a UL central station certificate requires 2 telephone lines. - ANSWER-False According to UL standards, you must have 1 spare digital receiver for how many active digital receivers? - ANSWER-5 Which connection method provides the highest data transfer rate? - ANSWER-Cable modem If an applicant for the qualifying exam has failed 3 tests, how long must they wait to retake the test? - ANSWER-6 months How long must an applicant wait to retake a qualifying exam? - ANSWER-30 days How many hours can be claimed per year as qualifying work experience? - ANSWER 2000 Alarm Alarm How many total hours of experience must you have to become a qualifying agent? - ANSWER-6000 For an alarm company license application, fingerprint cards are required for anyone owning what percent or more of the company? - ANSWER-5 percent How much general liability insurance coverage is required per incident - ANSWER 300000 When do DUI's disqualify a person from obtaining or holding a burglar alarm company or burglar alarm company agent's license? - ANSWER-2 in the last 3 years What is the minimum TOTAL general liability insurance coverage required for licensure? - ANSWER-1 million Who performs criminal background checks for renewals or reinstatement's of alarm company or alarm company agents licenses? - ANSWER-The division What false alarm rate will be considered unprofessional conduct for an alarm company? - ANSWER-100 percent above the average How long must an alarm business keep the training records for a system on file? - ANSWER-3 years from the training A type of security system that restricts access to unauthorized users at certain times - ANSWER-Access control A type of alarm verification that requires a central station operator to place two phone calls before dispatching the proper authorities - ANSWER-Enhanced call verification Which type of ladder is most recommended for alarm technicians? - ANSWER Fiberglass Is fall protection required by OSHA for employees climbing or working on portable ladders? - ANSWER-No How is a panic button most usually wired? - ANSWER-Normally open When do burglar alarm company licenses expire? - ANSWER-March 31 of odd years The transformer should only need what percent of its output to cover the needs of the alarm panel, devices, and battery charging? - ANSWER-80 percent If you wire(2) 12 volt 7 amp batteries in series, what is the voltage/amperage? - ANSWER-24 volts 7 amps Alarm Alarm If you wire (2) 12 volt 7 amp batteries in parallel, what is the voltage/amperage - ANSWER-12 volts 14 amps A "man-sized opening" is at least how many square inches? - ANSWER-96 What is the proper way to test an alarm system's back up battery? - ANSWER-Do a load test What type of branch circuit should be used for a Fire Alarm Panel? - ANSWER Individual What is the maximum distance you should run for IP cameras? - ANSWER-100 meters What is the advantage of using single-ended beam smoke detectors vs. dual-ended bean type? - ANSWER-Easier and cheaper If you have 4 devices wired in series together in a single zone, what happens to the amperage? - ANSWER-Nothing What is the minimum required spacing between Class 2 circuit wires and Class 3 circuit wires of no separating barriers? - ANSWER-2 inches If a transformer's internal fuse is blown, what will the meter read when testing it? - ANSWER-Open Occupancy Classification- Group A means.. - ANSWER-Assembly Occupancy Classification- Group B means.. - ANSWER-Business Occupancy Classification- Group E means - ANSWER-Education Occupancy Classification- Group F means.. - ANSWER-Factory and industrial Occupancy Classification- Group H means.. - ANSWER-High Hazard Occupancy Classification- Group I means.. - ANSWER-Institutional Occupancy Classification- Group M means - ANSWER-Mercantile Occupancy Classification- Group R means.. - ANSWER-Residential Occupancy Classification- Group S means - ANSWER-Storage Occupancy Classification- Group U means - ANSWER-Utility Alarm Alarm What room improvement does NOT have an adverse effect on the use of an audio discriminator? - ANSWER-New paint What wire should be used to ground a burglar alarm panel? - ANSWER-18/1 How long should a fire alarm's back up battery last during power failure? - ANSWER-24 hours plus 5 minutes in alarm state Per ADA, what is the maximum height to install an annunciator or an alarm keypad? - ANSWER-48 inches What is the maximum distance between staples in a wire run? - ANSWER-54 inches What distance from an outlet, switch or junction box is required to secure wire with a staple - ANSWER-Within 12 inches Detectors for humidity, low temp, water, freezing, gas, and carbon monoxide are considered what type of sensor? - ANSWER-Environmental Is a motion detector considered an environmental sensor? - ANSWER-No How do you configure environmental alarm zones? - ANSWER-24 hour zones What is the recommended distance between smoke detectors? - ANSWER-30 feet What distance must a smoke detector be installed from an air supply or return vent? - ANSWER-3 feet Smoke detectors should be mounted at least how far from a wall? - ANSWER-4 inches If you have (4) 100-ohm resistors in parallel, what is the load? - ANSWER-25 ohms How often must sealed lead-acid batteries be visually inspected? - ANSWER-Twice per year How soon is a backup battery required to be fully recharged after power is restored to the panel? - ANSWER-48 hours Does the state of Utah have overtime-pay statutes? - ANSWER-No On a job site, this is the most hazardous classification: - ANSWER-Class 1, division 1 According to UL 681, an opening is considered inaccessible if it is what distance above either the ground or the roof of an adjoining building? - ANSWER-18 feet What does a potential transformer measure? - ANSWER-High voltage Alarm When 2 sirens are wired in series, what happens to the voltage? - ANSWER-It drops If after a theft occurs there are cameras installed, what type of security planning is that? - ANSWER-Reactive What form is used by an employer to verify an employee's identity and establish that the worker is eligible to accept employment in the United States? - ANSWER-I-9 How many power supplies must a residential fire alarm have? - ANSWER-2 What is the best way to prevent false alarms? - ANSWER-Client education NFPA 72- In a room of typical height, the lens of a strobe should be mounted how high above the finished floor? - ANSWER-80-96 inches Are Class B SLCs allowed to be T-tapped? - ANSWER-Yes Fire alarm pull stations must be how close to the exit door? - ANSWER-5 feet What is the maximum coverage area for a single fire protection zone? - ANSWER 20000 square feet Securing cable to a wall without conduit is only allowed if above what height? - ANSWER-10 feet Maximum distance a strobe can be from the end of a hallway or corridor - ANSWER-15 feet Hardest to troubleshoot in an alarm system? - ANSWER-Moisture A device for storing charge - ANSWER-Capacitor Alarm

Meer zien Lees minder
Instelling
UTAH BURGLAR ALARM QUALIFYING AGENT
Vak
UTAH BURGLAR ALARM QUALIFYING AGENT

Voorbeeld van de inhoud

Alarm



UTAH BURGLAR ALARM QUALIFYING
AGENT QUESTIONS AND ANSWERS
EXAM 2026
UL Standard for intrusion detectors - ANSWER-639

UL Standard for connectors and switches - ANSWER-634

When installing NC door contacts (open on alarm), the EOL resistor should be placed -
ANSWER-In series at device

When installing NO door contacts (short on alarm), the EOL resistor should be placed -
ANSWER-In parallel at device

A motion detector that uses a transmit frequency of 20 to 40 KHz is referred to as a: -
ANSWER-Ultrasonic detector

A motion detector that uses a transmit frequency of 10-20 GHz is referred to as a: -
ANSWER-Microwave detector

PIRs transmit on a frequency of 100-200 KHz. T or F - ANSWER-False

T or F? PIRs are most sensitive to motion toward and away from the detector. -
ANSWER-False

T or F? Microwave detectors are most sensitive to motion toward and away from the
detector. - ANSWER-True

Biased magnetic contacts are used for - ANSWER-High security applications

T or F? Microwave detectors can penetrate glass, wood paneling and Sheetrock. -
ANSWER-True

T or F? Dual technology motion detectors are used to reduce false alarms. - ANSWER-
True

T or F? PIRs utilize the Doppler shift principle to detect motion. - ANSWER-False

Why are reed contacts are plated with rhodium or similar materials? - ANSWER-To
prevent welding

What is the National Electric Code? - ANSWER-NFPA 70

Alarm

, Alarm



What is the National Fire Alarm Code? - ANSWER-NFPA 72

Which UL standard covers the installation of burglar alarms? - ANSWER-681

What does the ANSI/SIA OSIPS DVI standard cover? - ANSWER-Video and ip related
interface

TIA/EIA 568 standard relates to: - ANSWER-Structured wiring

Who has final say on fire alarm system installation? - ANSWER-AHJ

T or F? Since ADA is a law, it has no effect on Codes. - ANSWER-False

T or F? Codes and Standards both have the same meaning. - ANSWER-False

Which standard is referred to as the Control Panel Standard, Features for False Alarm
Reduction? - ANSWER-ANSI/SIA CP-01-2007

T or F? ANSI is a leading standards developer in the United States. - ANSWER-False

T or F? ISO is the worlds largest developer and publisher of international standards. -
ANSWER-True

T or F? ISO 9000 describes the fundamentals of quality management systems. -
ANSWER-True

Which standard is referred to as the Digital Communication Standard, Internet Protocol
Event Reporting? - ANSWER-ANSI/SIA DC-09-2007

Which UL Standard is for Central Station Automation Systems? - ANSWER-1981

Which UL Standard covers Police Station Connected Burglar Alarm Units and Systems?
- ANSWER-365

Which UL Standard covers Central-Station Burglar-Alarm Systems? - ANSWER-611

What is the National Life Safety Code? - ANSWER-NFPA 101

A technique for allocating IP addresses dynamically so that the addresses can be
reused when the host no longer needs them is called - ANSWER-DHCP

CDPD is a type of - ANSWER-Cellular communicator

1400 Hz, 2300 Hz, and Dual tone are used as.. - ANSWER-Digital communicator
handshake

Alarm

Geschreven voor

Instelling
UTAH BURGLAR ALARM QUALIFYING AGENT
Vak
UTAH BURGLAR ALARM QUALIFYING AGENT

Documentinformatie

Geüpload op
21 april 2026
Aantal pagina's
7
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
AlexScorer
2.5
(2)

Maak kennis met de verkoper

Seller avatar
AlexScorer Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
9
Lid sinds
1 jaar
Aantal volgers
0
Documenten
1814
Laatst verkocht
1 maand geleden
Best Scorers Review Guide

Hesitate not to get 100% Recent updated and Verified Documents .Total Guarantee to success

2.5

2 beoordelingen

5
0
4
1
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen