Under which of these conditions shall the instrument air reserve header cylinders be permitted to be store with the instrument air compressor ? - ANSWERSThe only motor-driven machinery in the room is for the instrument air equipment Riser valves are those valves located where? - ANSWERSIn the riser adjacent to the main line Installers of a Category 1 medical gas piped distribution system must be qualified in accordance with ASSE 6010. What is the certification requirement for installers of a Category 3 medical gas piped distribution system ? - ANSWERS6010 When is the initial pressure test conducted by the installer? - ANSWERSAfter blow down of the distribution piping

Meer zien Lees minder
Instelling
Medgas
Vak
Medgas

Voorbeeld van de inhoud

MEDGAS EXAM QUESTIONS AND
ANSWES 2026
Under which of these conditions shall the instrument air reserve header cylinders be
permitted to be store with the instrument air compressor ? - ANSWERSThe only motor-
driven machinery in the room is for the instrument air equipment

Riser valves are those valves located where? - ANSWERSIn the riser adjacent to the
main line

Installers of a Category 1 medical gas piped distribution system must be qualified in
accordance with ASSE 6010. What is the certification requirement for installers of a
Category 3 medical gas piped distribution system ? - ANSWERS6010

When is the initial pressure test conducted by the installer? - ANSWERSAfter blow
down of the distribution piping

In those portions of systems intended to handle oxygen at pressure greater than 350
psi, the interconnecting hose shall not contain ________ materials -
ANSWERSPolymeric

Under what conditions is this method permitted for the installation of medical gas? -
ANSWERSWhere the limited make-up depth is not less than min. cup depth per
ANSI/ASME recommendations

What is the standard gauge pressure (PSI) for nitrogen gas service? - ANSWERS160-
185

Which of these is an NFPA 99 requirement for the labeling of pipes in a medical gas
system ? - ANSWERSColor coding

A wireless communication device is employed in a medical gas or vacuum warning
system. Which type of supervision is required for this device? - ANSWERSThe device
will be supervised such that failure of communication shall initiate an alarm

In a facility where medical gas or vacuum systems are present and the failure of such
equipment or system is likely to cause imminent major injury or death to patients or
caregivers, the system shall be designed to meet which category of requirements? -
ANSWERS1

A facility is in the planning stages of installing an emergency oxygen service connection
(EOSC). How many feet is the min. amount of clearance required around this
connection? - ANSWERS3 feet

, Which of the following conditions must be where medical gas and vacuum systems are
installed by non-certified personnel? - ANSWERSInstallation by anyone other than 6010
certified personnel is Not permitted

Wooden racks for cylinder storage may be permitted under which conditions? -
ANSWERSWooden racks are no longer permitted

A non-metal flexible connector is being used to connect the manifold to the gas
distribution piping. What is the max length for the flexible connector? - ANSWERS5 feet

Which type of copper tube hangers shall be used in a potentially damp location? -
ANSWERSplastic coated or insulated with a material that will not absorb moisture

Patient care room is any room of a health care facility wherein patients are to be ? -
ANSWERSexamined or treated

oxygen cylinders in use and in storage shall be prevented from reaching temperatures
in excess of how many degrees Fahrenheit? - ANSWERS130

Liquid containers shall have additional product identification visible from all directions
with a min. of ___ high letters - ANSWERS2 inches

24. Which of the following systems shall NOT be permitted to be located in an outdoor
enclosure ? - ANSWERSmedical air compressor supply sources

The final connection between new piping and an existing system may be tested with the
system gas and must be checked with a leak detectant that does not contain which of
these solvents? - ANSWERSammonia

A bulk cryogenic supply containing parallel-piped duplex line regulators. Which of the
following is a requirement for the regulators? - ANSWERSa balanced design

Which of these is a requirement for area alarm panels? - ANSWERSProvide visual and
audible indication

Excluding outdoor locations, which of these is an NFPA 99 requirement for the wiring of
each of the 2 mandatory master alarms ? - ANSWERSWired independently to the
initiating device for each signal

stainless tube may be joined by any methods except? - ANSWERSSolder

what sort of treatment shall be permitted before brazing the out ends of a tube to be
installed in medical gas piping systems? - ANSWERScut ends may be rolled smooth or
deburred

Geschreven voor

Instelling
Medgas
Vak
Medgas

Documentinformatie

Geüpload op
21 april 2026
Aantal pagina's
8
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$20.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
papersmaster01 Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
300
Lid sinds
2 jaar
Aantal volgers
106
Documenten
14577
Laatst verkocht
3 weken geleden
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

73 beoordelingen

5
22
4
34
3
10
2
3
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen