Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

ICC California UST Service Technician Exam 2026: Complete Q&A with Verified Answers

Rating
-
Sold
-
Pages
196
Grade
A+
Uploaded on
23-04-2026
Written in
2025/2026

Become a certified ICC California UST Service Technician! This is your ultimate exam prep resource, featuring the complete 2026 Final Examination with every question and the correct answer already provided – all verified and graded "A". This guide goes beyond basic operator knowledge, diving deep into installation, repair, secondary containment testing, confined space safety (Title 8), cathodic protection design, fiberglass tank repair, overfill prevention retrofits, and PEI RP 100/1200 standards. Every answer is referenced to the correct regulation (CCR Title 23, H&SC, PEI).

Show more Read less
Institution
Course

Content preview

1|Page




ICC California UST Service Technician Exam Questions 2026 Final
Examination WITH COMPLETE QUESTIONS AND CORRECT
ANSWERS |ALREADY GRADED A+|



Which agency approves a site-specific variance which allows for an
alternative method of construction or monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control
d.) The local agency - ANSWER--a.) The Regional Water Quality Board
CCR Title 23, Sec 2681(a)


The regulations to enforce compliance of underground storage tank
systems in the state are found in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17 - ANSWER--b.)
California Code of Regulations; Title 23, Chapter 16


By definition an "underground storage tank system" includes
a.) The tank, all connected piping and dispensers

,2|Page


b.) The tank, all connected piping, ancillary equipment and containment
system
c.) Only the tank
d.) Only tanks totally beneath the surface of the ground - ANSWER--b.)
The tank, all connected piping, ancillary equipment and containment
system


(H&SC, Sec 25281(z))


The written report submitted to the local agency after an unauthorized
release is required to include the following except:
a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered - ANSWER--b.) Cause of
the release
CCR Title 23, Sec 2652(c)


An unauthorized release which does not escape from secondary
containment only requires a record on the operator's monitoring
reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection

,3|Page


D. All of the above - ANSWER--D. All of the above
H&SC, Sec 25294


The annual monitoring certification may be performed by:
A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the
monitoring equipment
C. A designated UST operator
D. A person who meets the requirements of both a and b - ANSWER--D.
A person who meets the requirements of both a and b
CCR Title 23, Sec 2715(i)


When an automatic tank gauge is utilized for single-walled tank leak
detection, it shall generate a post-test hard copy data report of the
following information, except:
a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test - ANSWER--c.) Outside air temperature
CCR Title 23, Sec 2643(b)(1)


If a UST system is utilizing an overfill alarm, the alarm must be triggered
to alert the transfer operator when the tank is no more than
___________ full

, 4|Page


a.) 85%
b.) 95%
c.) 90%
d.) 80% - ANSWER--c.) 90%


An automatic tank gauge is utilized for leak detection of the
______________.
a.) Tank
b.) Tank and Piping
c.) Piping
d.) Interstitial space - ANSWER--a.) Tank
CCR Title 23, Sec 2643(b)(1)


After completion of enhanced leak detection (ELD) test, the ELD test
results must be submitted to the _________________.
a.) The local agency
b.) The SWRCB
c.) Owner of the UST system
d.) To both the SWRCB and the local agency - ANSWER--d.) To both the
SWRCB and the local agency
CCR Title 23, Sec 2644.1(a)(5)

Written for

Course

Document information

Uploaded on
April 23, 2026
Number of pages
196
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$27.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
blisslaw4

Get to know the seller

Seller avatar
blisslaw4 teach me2
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
2 months
Number of followers
0
Documents
409
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions