The__________may waive requirements for the
employment of a special inspection agency if he/she finds
that the construction is of minor nature.
-building official
-engineer or architect of record
-owner
-all of the above - Answer-building official
what is the maximum allowable center to center spacing of
spliced bars in a non-contact lap splice for the flexural
members?
-6 inches
-4 inches
-8 inches
-2 inches - Answer-6 inches
,2|Page
Drilled cast-in place concrete piles that poured with
concrete having an f'c of 2500 psi need special
inspection?
-only when required by the building official
-at the engineers discretion
-at all times
-when poured with concrete having an air entrainment
greater then 3% - Answer-at all times
The type of portland cement best suited for general use
when a moderate heat of hydration is desired is
- Type I
- Type II
- Type III
- Type V - Answer-Type II
Concrete containing pre-stressed tendons, embedded
aluminum, or cast against stay in place galvanized steel
forms shall not contain?
-lightweight aggregates
-pozzolans in excess of 5%
-fly ash in excess of 10%
,3|Page
-calcium chloride - Answer-calcium chloride
billet steel bars are marked by the letter_________on the
bars.
-S
-N
-A
-W - Answer-S
Concrete exposed to water with low permeability
requirements shall have a maximum w/c ratio of?
-0.4
-0.45
-0.5
-N/A - Answer-0.5
The following is not allowed in concrete unless it is coated
or protected from a reaction with other items in the
concrete?
-calcium chloride
-schedule 20 pipes
, 4|Page
-galvanized reinforced steel
-Aluminum - Answer-Aluminum
The last marking on a reinforcing steel bar is
- point of origin
- size
- type of steel
- minimum yield strength - Answer-minimum yield strength
An acceptable reinforcing steel support mechanism for a
24-inch deep footing are?
-precast dobie blocks
-large,solid pieces of glass
-masonry CMU pieces
-wooden blocks - Answer-Precast dobie blocks
all of the following are true except ?
---Minimum concrete cover for bundled bars of any size
need not be greater than 2 inches, unless they are in a
member that's permanently cast against earth