Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NYC Health Hospitals Electrician Exam Actual Test ||Verified Questions and Correct Answers With Rationales LATEST THIS YEAR.pdf||NEWEST EXAM!!!

Beoordeling
-
Verkocht
-
Pagina's
47
Cijfer
A+
Geüpload op
24-04-2026
Geschreven in
2025/2026

NYC Health Hospitals Electrician Exam Actual Test ||Verified Questions and Correct Answers With Rationales LATEST THIS YEAR.pdf||NEWEST EXAM!!!

Instelling
NYC Health Hospitals Electrician
Vak
NYC Health Hospitals Electrician

Voorbeeld van de inhoud

1|Page


NYC Health Hospitals Electrician Exam Actual Test
||Verified Questions and Correct Answers With
Rationales LATEST THIS YEAR.pdf||NEWEST EXAM!!!


In healthcare facilities, patient bed receptacles located in
general care areas shall be supplied by at least two
branch circuits, which ____permitted to originate from two
separate transfer switches on the emergency system -
Answer-Are permitted


Patient care areas of healthcare facilities ____ areas such
as business offices, corridors, lounges ,day rooms, or
similar areas - Answer-Do not include


The patient care area is any portion of the healthcare
facility where patients are intended to be ____or ____. -
Answer-Examined or treated


Each general care area patient bed location in a
healthcare facility must be provided with four ____ or ____
duplex receptacles - Answer-Single or two

,2|Page


A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour
basis of ____ or more patients - Answer-Four


Where installed to reduce electrical noise for electronic
equipment, electrical continuity of the metal raceways
shall not be required and metal raceway can terminate a
(an) ____ nonmetallic fitting or spacer on electronic
equipment - Answer-Listed fitting


Feeder and branch circuit conductors within ____ inches
of a Ballast shall have an insulation temperature rating not
lower than 90°C (194°F) unless supplying a luminaiere
marked as suitable for a different insulation temperature -
Answer-3 inches


Manufactured wiring systems constructed with type MC
cable shall be supported and secured at intervals not
exceeding ____ ft. - Answer-6 ft


Where a main bonding jumper or a system bonding
jumper is a screw only the screw shall be identified with a
____ that shall be visible with the screw installed -
Answer-Green finish

,3|Page




Plug fuses a 15 amperes and lower rating shall be
identified by a ____ configuration of the window, cap, or
other prominent part to distinguish them from fuses of
higher ampere rating - Answer-Hexagon


The load for household electric clothes dryer's in a
dwelling unit(s) shall be either ____ watts (volt-amperes)
or the nameplate rating, which ever is larger, for each
dryer served ? - Answer-5000 watts


Service conductors installed as unjacketed multiconductor
cable shall have a minimum clearance of ____ windows
that are designed to be opened, doors, porches, stairs fire
escape or similar locations. - Answer-3 ft (36 inches)


—— Cartridge fuses of the renewable type shall be
permitted to be used only for replacement in existing
installation is where there is no evidence of over-fusing or
tampering. - Answer-Class H


Branch circuit conductors within ____inches of the ballast
shall have an insulation temperature rating not lower it
90°C 194°F - Answer-3" inches

, 4|Page




The minimum radius of a field bend on trade size 1 "1/4
RMC is ____. - Answer-8


In a dwelling unit which appliance is allowed to have a
24"inch cord with Attachment ground plug ? - Answer-
Combination range hood/microwave oven
Type ____ is multiconductor cable identified for use as
underground service entrance cable. - Answer-Type USE
cable


Knife switch rated for more than 1200 Amps at 250Volts or
less - Answer-Can be used only as isolating switch, shall
not be opened under load


Track lighting with outlets in a bathroom is not allowed
because ? - Answer-Track lighting has receptacle


Where internal combustion engines are used as the prime
motor, an on site fuel supply shall be provided with an on
premise fuel supply sufficient for not less than ____ hours
full demand operation of the system - Answer-6 hours

Geschreven voor

Instelling
NYC Health Hospitals Electrician
Vak
NYC Health Hospitals Electrician

Documentinformatie

Geüpload op
24 april 2026
Aantal pagina's
47
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$25.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
TrustedExams

Maak kennis met de verkoper

Seller avatar
TrustedExams Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
6
Lid sinds
4 maanden
Aantal volgers
0
Documenten
1422
Laatst verkocht
2 weken geleden
EXCELLENT TUTOR

Welcome to my Stuvia store! I provide high-quality exam materials, including practice exams, past questions, and detailed solutions. All content is carefully prepared, accurate, and aligned with course requirements to help students revise effectively, boost confidence, and perform better in exams.

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen