Stop searching, start passing. This is the exact question bank you need to ace the EPA Type 3 (Low-Pressure Centrifugal Chillers) certification on your very first attempt. Curated for the 2026/2027 exam cycle, this document is packed with verified, A+ graded answers pulled directly from the latest testing pool. Why buy this bank? Real Questions, Real Answers: We cover everything from hydrostatic testing and purge units to complex leak rate calculations (10%, 20%, 30% thresholds) and ASHRAE standards. Targeted for High-Stakes: Focuses specifically on complex topics like low-pressure refrigerant recovery, evacuation levels (25mm Hg absolute), and rupture disc pressures (15 psig). Save Hours of Study: No fluff. Just the Q&A you need to memorize to walk into the exam feeling 100% confident.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

1|Page




EPA TYPE 3 2026/2027 BANK QUESTIONS WITH DETAILED
VERIFIED ANSWERS / EXAM QUESTIONS WILL COME
FROM HERE (100% CORRECT ANSWERS/ A+ GRADED




A hydrostatic thest kit will; - ANSWERS--determine if a tube leaks.


When leak testing a low pressure centrifugal with nitrogen, what is the
maximum test pressure? - ANSWERS--10 psig


Excessive running of a purge system on a low-pressure chiller generally
indicates what condition? - ANSWERS--Leaking system.


According to ASRAE Guidline 3, the system should be checked for leaks
if during a standard vacuum test the pressure in a system rises from 1
mm toa level above; - ANSWERS--2.5 mm Hg.


If an owner operator of an apliance with 50 or more pounds of an
ozone-depleting refrigerant charge are required to retrofit or retire an
appliance that has exceeded the treshold leak rate, how many months
do they have if the replacement appliance uses a refrigerant exempt
from venting prohibition? - ANSWERS--18 months

,2|Page


When must the leak rate of an appliance be calculated? - ANSWERS--
When topping off or recharging a system due to a loss of charge.


Starting in 2019, what is the leak rate threshold for comfort cooling
appliances with a full charge of 50 Or more pounds. - ANSWERS--10%


A typical setting for the high pressure cut-out control on a recvery unit
used for evacuating the refrigerant from a low-pressure chiler is; -
ANSWERS--10 psig


Refrigerant removal from a low-pressure system starts;with; -
ANSWERS--liquid removal


Why should the oil be removed from a low-pressure system at 130
degrees F.? - ANSWERS--Less refrigerant will be contained in the oil at
the higher temperature.


What is a typical advantage of a water cooled recovery unit? -
ANSWERS--Faster recovery of large quantities of refrigerant.


Why must water be circulated through a chiller during refrigerant
evacuation? - ANSWERS--To prevent freezing of water in the appliance.


Where is the lowest access point on a low-pressure air-conditioning
appliance? - ANSWERS--Evaporator charging valve

,3|Page




What should you do after reaching the required recovery vacuum on a
low-pressure appliance? - ANSWERS--Wait for at least a few minutes to
see if the system pressure rises before charging.


When should an appliance NOT be evacuated all the way to the
prescribed level? - ANSWERS--When leaks in the appliance make
evacuation to the prescribed level unattainable.


Which of the following statements is true of recycling and recovery
equipment? - ANSWERS--It must be labled as certified to meet EPA's
requirements.


How long must a technician evacuating refrigerant from appliances
with a full charge of more than 5 pounds and less than 50 pounds that
are being disposed of keep records of the event? - ANSWERS--3 years


What evacuation level must technicians recover refrigerant to before
disposing a low-pressure appliance? - ANSWERS--25mm of Hg absolute


Which of the following always falls under the EPA definition for "major,
maintenance, service, or repair?" - ANSWERS--Replacing a compressor.


Where is refrigerant added to a centrifugal machine? - ANSWERS--
Evaporator charging valve.

, 4|Page




Why do chillers using low-pressuree refrigerants require purge units? -
ANSWERS--These systems operate below atmospheric pressure.


Which of the following is a reason to take an oil sample? - ANSWERS--
The unit has a compressor burnout.


Which of the following indicates air in a low-pressure system? -
ANSWERS--High head pressure.


What should be used to remove ice fron sight glasses or viewing
glasses? - ANSWERS--Isopropyl alcohol


What is the typical design burst pressure for a rupture disk on a low-
pressure centrifugal air-conditioning system? - ANSWERS--15 psig


Where would you place a leak detector probe to check gas leaks into
the water box with the water removed? - ANSWERS--In the drain valve
opening.


Leak testing a low-pressure refrigeration system with nitrogen in excess
of 10 psig could cause which of the following to fail? - ANSWERS--
Rupture disc.

Geschreven voor

Vak

Documentinformatie

Geüpload op
24 april 2026
Aantal pagina's
48
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$27.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
blisslaw4

Maak kennis met de verkoper

Seller avatar
blisslaw4 teach me2
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
1 maand
Aantal volgers
0
Documenten
409
Laatst verkocht
-

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen