| 2026 | 100% Verified | A+ Pass
• The eastern sub termite belongs to what family? -✓✓Rhinotermitidae
• Drywood and dampwood termites belong to the family? -✓✓Kalotemritidae
• according to the revised taxonomy of termites, these insects belong in the order ____
along with cockroaches -✓✓Blattodae
• the Old House Borer is a example of? -✓✓Longhorned wood borer
• which is required to be reported on the Form 13645? -✓✓Evidence, Damage and live
organisms
• When must you use a form 13645 inspection report? -✓✓For real estate transactions,
and for real estate transactions when a written report is requested
• which is the minimum amount of errors on omissions liability insurance? -
✓✓$500,000/$250,00
• which are the two documents that can give you guidance on completing a form 13645
inspection report? -✓✓The industry baseline practices and the guidelines for the use
and completion of the form 13645
• Under the definition as they pertain to wdo inspections, live or living would include all
of the following EXCEPT? -✓✓powerpost beetle frass streaming out of holes
• under the definitions as they pertain to wdo inspections, structures would include all of
the following but not? -✓✓detached private fences
• you would report damage and deterioration to particle board and masonry siding
caused by exposure to water and sunlight, including the delamination water stains,
peeling, separation and other break down cellulose materials on a form 13645
inspection report -✓✓false
• which of these items could be stated as areas excluded from an exterior of a structure
from the form 13645 inspection report? -✓✓stored items and debris stacked against the
structure
• which of the following is not an example of a conducive condition that may lead to the
presence of wood destroying organisms? -✓✓wood roof shingles
, • which would not be a valid reason for excluding the inspection of the entire attic of a
structure? -✓✓insulation covers trust trails
• conducive conditions for termite or wood decaying fungi infestations would include all
of the following but not? -✓✓oak trees located on the property
• if you do not properly check any boxes in Section 3 (obstructions and inaccessible
areas) on form 13645, then you have indicated that? -✓✓the area was inspected and
considered accessible
• as part of the wdo inspection, evidence of a wood destroying organism would not
include? -✓✓Ambrosia Beetle stains
• the purpose of the wdo inspection report is to communicate information about the
presence or absence of wood destroying organisms at the time of the inspection,
therefore, it is considered to be warrantied for? -✓✓none of the above
• according to the industry Baseline practices, what is the minimum opening size for an
attic entrance? -✓✓20" x 20"
• according to the industry Baseline practices what is the minimum opening size through
the truss webbing in the Attic? -✓✓22" x 48"
• which of the following reasons would not allow you to exclude the crawl space of a
structure from The Forum 13645 inspection? -✓✓plastic vapor Barrier on the ground
• which one of the following would not be evidence of previous treatment of a structure
during a form 13645 inspection? -✓✓drill holes in a tree stump
• which are the two categories of application equipment used for subterranean termites
soil treatments? -✓✓above-ground and below-ground
• what is the basic reason to use foam instead of a liquid termiticide -✓✓foam flows
around pipes and other debris
• the following are examples of above ground application equipment accepting? -
✓✓sub-slab injector
• which is the federal statutes that regulate the pest control industry? -✓✓Federal
Insecticide Fungicide rodenticide Act
• in Florida which of the following statutory chapters covers the pesticide storage
facility? -✓✓chapter 252