Michigan Fire Suppression System Contractor Licensing Exam
ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT
ANSWERS LATEST UPDATE THIS YEAR
Michigan Fire Suppression System Contractor Licensing Exam
ACTUAL EXAM COVERAGE (ALL CONTENT AREAS)
1. Fire Protection Fundamentals
• Fire triangle and combustion principles
• Types of fire (Class A, B, C, D, K)
• Fire behavior and spread dynamics
• Suppression principles
2. Sprinkler System Types
• Wet pipe systems
• Dry pipe systems
• Pre-action systems
• Deluge systems
• Standpipe systems
3. NFPA Standards & Codes
• NFPA 13 (sprinkler systems)
• NFPA 14 (standpipes)
• NFPA 20 (fire pumps)
• NFPA 25 (inspection, testing, maintenance)
4. Hydraulic Calculations
• Pipe sizing and friction loss
• Water demand calculations
• Pressure requirements
• Density and design curves
5. Fire Pumps & Water Supply
• Pump types (centrifugal, vertical turbine)
• Pump controllers
• Tank and municipal supply systems
• Pressure maintenance
6. Installation Practices
• Pipe joining methods (grooved, threaded, welded)
• Hanger spacing and support
• System layout requirements
• Corrosion protection
7. Inspection, Testing, and Maintenance (ITM)
• Weekly/monthly/annual inspections
• Flow tests and alarm testing
, Page 2 of 102
• Valve supervision
• Recordkeeping requirements
8. System Components
• Sprinkler heads (upright, pendent, sidewall, concealed)
• Control valves
• Flow switches and tamper switches
• Alarm devices
9. Safety & Code Compliance
• Contractor licensing laws
• Permitting requirements
• Jobsite safety practices
• OSHA basics for fire systems
1.
A sprinkler system designed to activate only after a detection system confirms fire conditions is
classified as what type?
A. Wet pipe system
B. Pre-action system
C. Dry pipe system
D. Deluge system
Answer: B
2.
, Page 3 of 102
What is the primary purpose of NFPA 13 in fire protection systems?
A. Electrical wiring standards
B. Installation of sprinkler systems
C. Gas pipeline safety
D. Structural design codes
Answer: B
3.
A dry pipe system is primarily used in which environment?
A. Heated buildings
B. Areas subject to freezing temperatures
C. Underground tunnels only
D. Kitchens
Answer: B
4.
, Page 4 of 102
What is the main function of a fire pump in a sprinkler system?
A. Reduce water flow
B. Maintain required pressure and flow
C. Drain system
D. Detect smoke
Answer: B
5.
Which sprinkler head type is most commonly used in commercial ceilings?
A. Sidewall
B. Pendent
C. Upright only
D. Open deluge
Answer: B
6.