CORRECT ANSWERS
Identify cthe cmaterials cused cfor cenclosure c- cCORRECT cANS✔✔Drywall
vinyl csiding
Plywood
Paneling
Caulk cand csealant
Hazards cthat cexist cin cresidential cenvironments c- cCORRECT cANS✔✔Lead cdust
Lead ccontaminated csoil
Peeling, cchipping cpaint
Folk cremedies
Describe chow cchildren care ctypically cexposed cto clead c- cCORRECT cANS✔✔Hand cto cmouth cactivities
Worker ctake chome cdust
Identify cthe ccommon croutes cof cworker clead cexposure c- cCORRECT cANS✔✔Inhalation
Ingestion
Describe cthe cbasic chealth ceffects cof clead cto cworkers c- cCORRECT cANS✔✔Stomachache
Nausea
Headache
Memory closs
High cBlood cpressure
Kidney cdamage
Describe cthe cOSHA c( cand cother crequirements) cfor clead cabatement cworker ctraining c- cCORRECT cANS✔✔Info con crespirators
cand ctheir cuse, ctypes, cproper cfit
Medical cexams cfor ceveryone cworking cwith clead
Describing cwhat cyour cemployer cis cdoing cto creduce cyour cexposure cto clead
Describe cthe cRCRA cregulations cand cregulated cinformation cregarding cwaste cdisposal cfor clead cabatement cprojects c-
cCORRECT cANS✔✔Commercial/ cindustrial cprojects- ctested, clabeled, chauled ccorrectly
Residential cproperty- chousehold chazardous cwaste cexemption
Identify cthe clead cRCRA cdefinitions cof chazardous cwaste cand ctesting cprocedures c- cCORRECT cANS✔✔TCLP ctest- ctoxic
ccharacteristic cleaching cprocedure
Detects chow cmuch clead cwould cleach cout cof cthe cwaste. c5mg/l= chazardous cwaste
Lead cmeets cthe ctoxicity cpart cof cbeing ca chazardous cwaste
"Competent cPerson cfor chealth cand csafety" cas cdefined cby cOSHA c- cCORRECT cANS✔✔A cperson cwho ccan cidentify chazards
Someone cwho ccan ctake ccorrective caction
OSHA crespirator cprotection cstandards crelevant cto clead cabatement cwork c- cCORRECT cANS✔✔When cabove cthe cpermissible
cexposure climit:
Need cto cwear cHEPA cfilter cand cany cother cappropriate cfilter
Have ca cwritten crespiratory cprogram cin cplace
OSHA cgeneral cindustry cstandards crelevant cto clead cabatement cwork c- cCORRECT cANS✔✔Similar cto cthe cconstruction crule
cexcept: cit cpertains cto cexposure cto clead cwhen cit cis cnot
Construction
Agriculture
Factory cmanufacturing
Medical cremoval cis cdifferent
Return cto cwork clevel cis cdifferent
Describe cblood cmonitoring crequirements c- cCORRECT cANS✔✔If cair cmonitoring cis cabove cthe caction clevel
30ug/m3 cfor cmore cthan c30 cdays/year
, Every c2 cmonths cfor cthe cfirst c6 cmonths
If cabove c40ug/dl cthen cback cto cevery c2 cmonths
At c50ug/dl- cmedical cremoval c(if c2 cconsecutive ctests)
Recognize cthe ccorrect cwording cof clead cwording csigns c- cCORRECT cANS✔✔DANGER: cLead cwork carea
May cDamage cFertility cor cthe cUnborn cChild, cCause cDamage cto cthe cCentral cNervous cSystem, cDo cNot cEat, cDrink, cor cSmoke
cin cthis cArea
Describe cthe cOSHA cconstruction cstandards c(other cthan clead cregs) c- cCORRECT cANS✔✔-Fall cprotection
-Eye cprotection
-Hazard cCommunication
-Anything chaving cto cdo cwith cworker cprotection cand cconstruction c(including casbestos)
Describe cthe cgeneral crequirements cspecified cby cthe cOSHA cconstruction cstandards c- cCORRECT cANS✔✔-Train cyour cpeople
-Monitor cthe cair cthey're cbreathing c(PEL cis c50ug/m3, cAL cis c30ug/m3)
-Take csteps cto creduce cexposure cto clead
-Do cblood cmonitoring
Keep cadequate crecords
Describe cthe cexposure cmonitoring cand cwritten ccompliance cplan crequirements cspecified cby cthe cOSHA clead cin cconstruction
cstandards c- cCORRECT cANS✔✔-Depending con cwhat cClass cwork cit cis, cassume ca ccertain cexposure cof clead
-Adjust crespirator cafter cfinding cout cwhat cexposure cis
-Document cwhat ctype cof cwork cis cbeing cdone
-Exposure cbelow cAL c(30ug/m3) cis cconsidered cnegative cassessment. cnot crepeated cuntil cjob cconditions cchange
-If cexposure cis cabove cPEL c(50ug/m3) cmonitor cevery c3 cmonths
-between c30-50ug/m3, cmonitor cevery c6 cmonths
-written ccompliance cplan
Exposure cassessment cschedule cwhen cassessment creports clevels cbelow cAL c(30ug/m3) c- cCORRECT cANS✔✔Not crepeated
cuntil cjob cconditions cchange
Exposure cassessment cschedule cif cexposure cis cabove cPEL c(50ug/m3) c- cCORRECT cANS✔✔Every c3 cmonths
Exposure cassessment cschedule cif cexposure cis cbetween cAL c(30ug/m3) cand cPEL c(50ug/m3) c- cCORRECT cANS✔✔Every c6
cmonths
OSHA chazard ccommunication cstandards c(HAZCOM) crelevent cto cLead cAbatement cwork c- cCORRECT cANS✔✔-Train cworkers
cabout chazards cthey're cworking cwith cand chow cto crespond cappropriately
-label ccontainers
-Distribute cMSDS
OSHA cAction cLevel cfor clead c- cCORRECT cANS✔✔30ug/m3
OSHA cPermissible cexposure clevel cfor clead c- cCORRECT cANS✔✔50ug/m3
How coften cdo clead cabatement csupervisors cneed cto ctake ca crefresher ccourse? c- cCORRECT cANS✔✔Every c2 cyears
The cunits cused cto cexpress clead clevels cin cair c- cCORRECT cANS✔✔ug/m3
The cunits cused cto cexpress clead clevels cin csoil c- cCORRECT cANS✔✔ppm
The cunits cused cto cexpress clead clevels cin cdust c- cCORRECT cANS✔✔ug/sq cft.
HUD cand cEPA cpost-abatement cclearance cstandards cfor clead cin cdust c- cCORRECT cANS✔✔Floor= c40 cug/ft2
Sill= c250 cug/ft2
Well= c400 cug/ft2
Describe cthe cpurpose cand cfocus cof cthe cHUD cguidelines c- cCORRECT cANS✔✔- cProvide cguidance cfor cfederally cassisted
chousing
- cIt chas cbecome ca cstandard cfor cthe cindustry
Why cis cit cimportant cto censure cthat cworker ccertification ccards cand ccertificates care ccurrent? c- cCORRECT cANS✔✔- cSo cthey
cdon't chave cto ctake cthe cfull ccourse cagain
- cSo cthat cthe csupervisor cdoesn't cget cfined cfor chaving cpeople cwith cexpired ccards con csite
Wisconsin cDHS c163 ccertification crequirements cfor clead cworker c- cCORRECT cANS✔✔Lead csafe crenovator cclass
Lead cabatement cwork cclass
Submit capplication cand cfee cto cDHS
WI cDHS c163 ccertification crequirements cfor csupervisor c- cCORRECT cANS✔✔- c1 cday clead csafe crenovator cclass
- cOne cday clead cabatement cwork cclass cand crelated cexperience
- c2 cyrs cconstruction cexperience cor c1 cyr cas clead cworker