▶ Very Extra High. Answer: A green color code green indication on a heat
detector indicates what operating temperature classification ?
▶ 4.04 ohms. Answer: What is the wire resistance in ohm of 500 feet of 18
AWG solid copper which is a coated at 75 degrees C?
▶ 96" AFF and a least 6" below the ceiling. Answer: what is the
appropriate mounting high for audible notification appliance?
▶ listed. Answer: A multi criteria device shall be ____ for the primary
function of the device
▶ 15%. Answer: Spaces separated by a partition shall be considered as
separate room for projected beam smoke detectors when the partition
extend to within what percentage of the ceiling high?
▶ Soft tissue injuries. Answer: which of the following is caused by muscle
pains and spams?
▶ 3.19 ohm. Answer: what is the wire resistance in ohms, of 1000 feet of
14 AWG solid copper which is coated at 75 degrees C?
▶ 200 seconds. Answer: a trouble signal shall be indicated and recorded
with____seconds?
▶ Shunt. Answer: What type of auxiliary fire alarm system does not permit
the use of automatic detectors?
▶ 110 %. Answer: A steam pressure supervisory shall indicate a low
pressure condition .The off normal signal be initiated prior to the pressure
falling below _____% of the minimum operating equipment supplied?
▶ 7 AMP. Answer: A non power limited fire alarm circuit which 18 AWG
shall have over current protection not to exceed ___ amperes?
, ▶ The system designer. Answer: the features for non required system
shall be established by _____ on the basis of the goals and objectives of
the building owner ?
▶ 8.08 ohm. Answer: What is the resistance in ohms, of 1000 feet of 18
AWG solid copper which is coated at 75 degrees C?
▶ Listing. Answer: The effect of guards, covers, or lents on the appliances
field performance shall be in accordance with _____requirements?
▶ monthly. Answer: What is the testing frequency for household smoke
alarm ?
▶ Proprietary Supervisory Station Service. Answer: What type of
supervising station fire alarm system is characterized by the bldg .Which
are protected and the supervising station being under the same ownership?
▶ FPLP. Answer: which of the following are acceptable cable for use in an
environmental air return space ?
▶ monthly. Answer: Consider a household fire alarm system which
communicates to a supervising station .What type is the testing frequency
for the communication path?
▶ 2 devices. Answer: In corridors where more than _____ visible
notification appliances are in any field of view they ,shall be synchronized.
▶ 6 smk det. Answer: Consider a room with smooth a flat 10' ceiling which
is 60' x 90' .What is the minimum number of smoke detectors required to
cover this space?
▶ Check for breathing. Answer: what measures should be taken after
determining the extent of a wounded person injury?
▶ 16 feet. Answer: Consider the use of visible appliances in sleeping
areas.For rooms with a linear dimension greater than 16 feet, the visible
appliance shall be located within _____feet of the pillow?
▶ 18 months. Answer: When a device is inaccessible due to excessive
height, such as an atrium, what it the maximum interval for testing?
COMPLETE STUDY GUIDE 2026
▶ Very Extra High. Answer: A green color code green indication on a heat
detector indicates what operating temperature classification ?
▶ 4.04 ohms. Answer: What is the wire resistance in ohm of 500 feet of 18
AWG solid copper which is a coated at 75 degrees C?
▶ 96" AFF and a least 6" below the ceiling. Answer: what is the
appropriate mounting high for audible notification appliance?
▶ listed. Answer: A multi criteria device shall be ____ for the primary
function of the device
▶ 15%. Answer: Spaces separated by a partition shall be considered as
separate room for projected beam smoke detectors when the partition
extend to within what percentage of the ceiling high?
▶ Soft tissue injuries. Answer: which of the following is caused by muscle
pains and spams?
▶ 3.19 ohm. Answer: what is the wire resistance in ohms, of 1000 feet of
14 AWG solid copper which is coated at 75 degrees C?
▶ 200 seconds. Answer: a trouble signal shall be indicated and recorded
with____seconds?
▶ Shunt. Answer: What type of auxiliary fire alarm system does not permit
the use of automatic detectors?
▶ 110 %. Answer: A steam pressure supervisory shall indicate a low
pressure condition .The off normal signal be initiated prior to the pressure
falling below _____% of the minimum operating equipment supplied?
▶ 7 AMP. Answer: A non power limited fire alarm circuit which 18 AWG
shall have over current protection not to exceed ___ amperes?
, ▶ The system designer. Answer: the features for non required system
shall be established by _____ on the basis of the goals and objectives of
the building owner ?
▶ 8.08 ohm. Answer: What is the resistance in ohms, of 1000 feet of 18
AWG solid copper which is coated at 75 degrees C?
▶ Listing. Answer: The effect of guards, covers, or lents on the appliances
field performance shall be in accordance with _____requirements?
▶ monthly. Answer: What is the testing frequency for household smoke
alarm ?
▶ Proprietary Supervisory Station Service. Answer: What type of
supervising station fire alarm system is characterized by the bldg .Which
are protected and the supervising station being under the same ownership?
▶ FPLP. Answer: which of the following are acceptable cable for use in an
environmental air return space ?
▶ monthly. Answer: Consider a household fire alarm system which
communicates to a supervising station .What type is the testing frequency
for the communication path?
▶ 2 devices. Answer: In corridors where more than _____ visible
notification appliances are in any field of view they ,shall be synchronized.
▶ 6 smk det. Answer: Consider a room with smooth a flat 10' ceiling which
is 60' x 90' .What is the minimum number of smoke detectors required to
cover this space?
▶ Check for breathing. Answer: what measures should be taken after
determining the extent of a wounded person injury?
▶ 16 feet. Answer: Consider the use of visible appliances in sleeping
areas.For rooms with a linear dimension greater than 16 feet, the visible
appliance shall be located within _____feet of the pillow?
▶ 18 months. Answer: When a device is inaccessible due to excessive
height, such as an atrium, what it the maximum interval for testing?