Michigan Electrical Sign Contractor License Exam
ACTUAL VERIFIED EXAM COMPLETE QUESTIONS
AND CORRECT ANSWERS LATEST UPDATE THIS
YEAR.pdf 1||NEWEST EXAM!!!
The volt Ampere rating of a device that consumes 14.5 A
on a 240 V circuit is_____. - Answer-3480watts
A 208 V, three phase heater draws 3598 W . How many
campers does the heater draw - Answer-10
The underwater light fixture shall be installed at least
________inches below the water level - Answer-18
A general purpose receptacle shall not be installed on
the_________ - Answer-Offense directly south of the pool
1. Where PV system DC circuits are run inside a building,
they shall be contained in metal raceways,____ or metal
enclosures from the point of penetration of the surface of
the building to the readily accessible disconnecting
means. - Answer-Type MC cable 690.31.G
,2|Page
2. Unless specifically listed and marked for the location,
the coupling means of the electric vehicle supply
equipment shall be stored or located at a height of not less
than___ inches above the grade level for outdoor
locations. - Answer-24' 625.50
There are six conductors in a race way connected to 75° C
rated circuit breaker. Each wire has a 70 amp load using
THHM conductors. The minimum size conductors used
our #_________AWG - Answer-4
Thermal insulation shall not be installed within
_________inches of recessed lighting fixtures - Answer-3
A 1 inch conduit contains three wire circuits or a phase
system. All conductors are number 10 TW. Each circuit
consist of two phase conductors and one grounding
conductor and one equipment grounding conductor. The
maximum and pasty of each phase conductor is______. -
Answer-24 amps
3. Unless specifically listed and marked for the location,
the coupling means of the electric vehicle supply
equipment shall be stored or located at a height of not less
, 3|Page
than___ inches above the floor level for indoor locations. -
Answer-18" 625.50
4. All 15 and 20 ampere, 125 volt non locking type
receptacles installed in the vehicle washing area of a
carwash shall be listed and so identified as___ type. -
Answer-weather resistant 406.9.B1
5. All 15 and 20 ampere, 125 volt non locking type
receptacles installed in the vehicle washing area of a
carwash shall have an enclosure that is____ whether or
not the attachment plug cap is inserted - Answer-weather
proof 406.9.B
6. An individual, other than an individual who is licensed
under this article and___ and working under the direction
of a holder of an electrical contractor's license, shall not in
any manner undertake to execute any electrical wiring. -
Answer-employed by PA.407 339.5737
7. The ratio of electrical journeyman or master electricians
to registered apprentice electricians shall be on the basis
of___ electrical journeyman or master electricians to no