and Answers Updated 2026
AApatientArecentlyAdiagnosedAwithAaAREMAdisorderAwishedAtoAhaveAanotherAsl
eepAstudyAinAaAdifferentAlabAtoAconfirmAtheAdiagnosis.AWhatAwouldAtheAtechn
ologistAexpectAtoAobserveAthatAwouldAconfirmAtheApatient'sAdiagnosisAofAaARE
MAdisorder?A-AAnswerADecreasedAREMAlatency
TheAAmericanAAcademyAofASleepAMedicineAgrantsAlaboratoryAaccreditationAforA
aAperiodAofAhowAmanyAyears?A-AAnswerA5Ayears
WhileAperformingAaAPSGAonAaApatient,AtheAECGAchannelAbecomesAaAstraightAl
ine.AWhatAshouldAtheAtechnologistAdoAfirst?A-AAnswerAEvaluateAtheApatient
DuringAanAevalutationAofAanA80AyearAoldAmanAforAPSG,AhisAdaughterAexplain
sAtoAtheAphysicianAthatAherAfatherAoftenAbecomesAconfusedAandAoftenAupset,A
especiallyAinAtheAearlyAevening.ATheAmanAshowsAsignsAofAdementia.AWhatAofA
theAfollowingAisAtheAmostAappropriateAconclusionAonAtheAbasisAofAthisAinform
ation?A-AAnswerATheApatientAshowsAsignsAofAsundowning
WhileAviewingAandAECGAfromAaApatient,AtheAtechnologistAnotesAthatAtheATAwa
veAisAuprightAandArelativelyAtheAsameAsizeAasAtheAPAwave.AHowAshouldAthisA
beAinterpreted?A-AAnswerARepolarizationAofAtheAheart
IfAtheAdistanceAfromAFpzAtoAOzAisA48Acm,AwhatAisAtheAdistanceAfromAPzAtoA
Oz?A-AAnswerA9.6Acm
AAphysicianAordersAtranscutaneousAmonitoringAduringAaAPSGAforAaA34AyearAol
dAfemaleAwithAanemia.ATheAtechnologistAshouldAexpectAtheAdisplayedAvaluesAt
oAbe...A-AAnswerALowerAthanAtheApatientsAvalues
TheAtermA"vegetativeAorganism"ArefersAto...A-
AAnswerAGrowingAmicroorganisms
,WhatAisAtheArecommendedAinitialApressureAforAaApatientAreceivingACPAPAthera
py?A-AAnswerA4AcmH2O
WhenAtheAsensitivityAamplifierAisAincreasedAfromA10Auv/mmAtoA5Auv/mm,Athe
ApenAdeflectionAshould...A-AAnswerADecreaseAbyAhalf
WhenAinformingAaApatientAofAhis/herAmedicalArights,AwhichAofAtheAfollowingA
shouldANOTAbeAincluded?A-AAnswerAInvoluntaryAparticipationAbyAtheApatient
WhileArecordingAanAovernightAsleepAstudy,AtheAtechnologistAnotesAthatAsomeAo
fAtheAEEGAwaveformsAareAdistorted.AInAorderAtoAimproveAtheAappearanceAofAt
heAwaveforms,AtheAtechnologistAshouldAadjustAthe...A-AAnswerASamplingArate
WhatAisAtheAinputAvoltageAwithAaApenAdeflectionAofA18AmmAandAsensitivityAo
fA5AuV/mm?A-AAnswerA90AuV
AAfemaleApatientArefusesAtoAhaveAtheAfingernailApolishAremovedAfromAherAfin
gerAforApulseAoximetryAduringAanAovernightAsleepAstudy.AHowAwouldAthisAaffe
ctAtheAdisplayedApulseAoximetryAvalue?A-AAnswerAFalseAhighAreading
WhatAareAtheAprimaryAreasonsAforArecordingAeyeAmovementsAduringAaAsleepA
study?A-
AAnswerAToAcaptureAslowArollingAeyeAmovementAatAtheAbeginningAofAsleep,Aa
ndAtoAseeAphasicAburstsAofArapidAeyeAmovement
AcidAgluteraldehydeAwillAfunctionAasAaAsporicidalAin:A-AAnswerA1Ahr
AnAECGAtracingAwithAaAQRSAcomplexAofA0.16AsecAshouldAbeAinterpretedAas...A
-AAnswerAVentricularAtachycardia
AApatientAwithAemphysemaAisAundergoingAaAPSGAtest.AEEGAhook-
upAandAattachmentAofAtheApulseAoximetryAprobeAhasAbeenAcompleted.ATheAinit
ialApulseAoximetryAsaturationAreadingAisA80%.AAfterA7Aminutes,AtheAdisplayed
, AsaturationAisA82%.ATheAtechnologistAshould...A-
AAnswerAStartAtheApatientAonA1AL/minAofAnasalAoxygenAandArecheckAtheApuls
eAoximetryAsaturationAinA10Aminutes
WhatAisAtheAvoltageAifAaAunitAhasAaApenAdeflectionAofA8mmAandAaAsensitivit
yAofA5AuV/mm?A-AAnswerA40AuV
TheAfirstAepochAofAanyAstageAofAsleepAisAdefinedAas...A-AAnswerASleepAonset
IfAG1AandAG2AreceiveAanAinputAsignalAofA50AuV,AwhatAwouldAtheAoutputAsig
nalAbe?A-AAnswerA0AuVA(TheyAwillAcancelAeachAotherAout)
AApatientAhasAanAMSLTAscoreAofA8.AThisAshouldAbeAinterpretedAas...A-
AAnswerATroublesome
IfAtheAinputAvoltageAisA500AuVAandAtheAsensitivityAisA150AuV/mm,AwhatAwou
ldAtheApenAdeflectionAbe?A-AAnswerA3.33Amm
AApatientAhadAsleepAonsetAonAepochA30AwithAtheAfirstAstageAofAREMAoccurrin
gAatAepochA250.AHowAshouldAREMAlatencyAbeAscored?A-AAnswerA110Aminutes
PatientAgroundingAcanAbeAdescribedAas:A-
AAnswerAAAreferenceAforAtheAotherAelectrodes,AandAasAaApathAfromApatientAto
Aearth
AApatientAhasAbeenAdiagnosedAwithAcircadianArhythmAdisorder.AWhatAtherapyA
shouldAtheAtechnologistArecommend?A-
AAnswerABrightAlightAtherapyAinAtheAevening
AnAECGAtracingAshowsAanAatrialArateAofA80/minAandAaAventricularArateAofA32
/min.ATheAPRAintervalAcannotAbeAdeterminedAandAtheAQRSAcomplexAisAwidene
d.AThisAbestAdescribesAwhichAofAtheAfollowing?A-
AAnswerA3rdAdegreeAAVAblock