Solved
- ✔✔✔-___________________ is a key consideration for the driver/operator that is critical for
building a successful team, instilling confidence in crew members, and supporting positive
response outcomes.
_________________ is a term used in electrical engineering to refer to the process of
combining information from several different sources. - ✔✔✔-Multiplexing
_____________________ equipment includes portable tools and equipment carried on an
apparatus, not including hose, ladders, fixed power sources, reels, breathing air systems, or
other major equipment or components specified by the purchaser to be permanently mounted
on the apparatus as received from the apparatus manufacturer. - ✔✔✔-Miscellaneous
_________________were rotary gear pumps and could generate as much as 200 gallons (800 L)
of water per minute. - ✔✔✔-Booster Pump
0.4 volt - ✔✔✔-What is the maximum allowable voltage drop when performing the voltage
drop test of the starter on an apparatus with a 24-volt system?
0.434 psi - ✔✔✔-What would be the pressure at the bottom of a water- filled cylinder that is 1
ft tall?
1 = 150 3 with 2 1/2 couplings = 0.8 - ✔✔✔-
1 1/2 - ✔✔✔-A collapse zone is a distance of _____________________ times the height of the
building in which fire fighters and fire apparatus must not be located in case of a building
collapse.
1 1/2 = 24 3 with 3 couplings = 0.67 - ✔✔✔-
,TCFP Driver Operator Mastercalss Exam with Questions and Answers – 100%
Solved
1 3/4 = 15.5 3 1/2 = .34 - ✔✔✔-
1 minute - ✔✔✔-In accordance with NFPA 1901, a fire apparatus wiht a completely discharged
air system must be able to move within _________________ of start up.
1:1 - ✔✔✔-When transferring the power from the rear axle to a fire pump, what is the typical
gear ratio?
1. The process of transferring the supply of water from the internal apparatus water tank to an
external source is known as a(n):
A. changeover operation.
B. dynamic conversion.
C. transfer operation.
D. intake conversion. - ✔✔✔-answer: A
NFPA 1002: 4.3.7, 4.3.7(A), 5.2.4(1), 5.2.4(2), 5.2.4(3), 5.2.4(4), 5.2.4(A)
Page: 290
1. What is the atmospheric pressure at sea level?
A. 3.1417 psi (22 kPa)
B. 7.69 psi (53 kPa)
C. 14.7 psi (101 kPa)
D. 21.3 psi (147 kPa) - ✔✔✔-answer: C
NFPA 1002: 10.2.1, 10.2.1(A)
Page: 324
1. What is the term that best defines the process of sending out emergency response resources
promptly to an incident location for a specific purpose?
,TCFP Driver Operator Mastercalss Exam with Questions and Answers – 100%
Solved
A. Communications
B. Dispatch
C. MDT
D. Paging - ✔✔✔-answer: B
NFPA 1002: N/A
Page: 255
1/2 - ✔✔✔-Water a 32 degrees Fahrenheit is almost ________________ pounds per cubic foot
heavier than water at 100 degrees Fahrenheit.
2 - ✔✔✔-Ten degrees of play is equivalent to ___________ inches of movement at the rim of a
20-inch steering wheel.
2 - ✔✔✔-What is the minimum number of 2.5 inch discharge outlets required for a pump rated
at 750 gallons per minute or greater.
2 mi/h - ✔✔✔-When the fire apparatus is designed for pump-and-roll operations, the fire
apparatus engine and drive train must be arranged so that the unit can pump at least 20 gpm at
a gauge pressure of 80 psi while the fire apparatus is moving at a speed of:
2 minutes - ✔✔✔-If the fire apparatus engine does not start within 30 seconds after the starter
has been engaged release the starter switch and allow the starter motor to cool for
__________________ before attempting to start it again.
2. Unsecured equipment in the crew compartment can prove dangerous if the apparatus must
stop or turn quickly, because:
A. they can distract the driver.
B. hazardous materials are more susceptible to spilling.
, TCFP Driver Operator Mastercalss Exam with Questions and Answers – 100%
Solved
C. it can easily get lost or roll out an open window.
D. a flying tool, map book, or PPE can seriously injure a fire fighter. - ✔✔✔-answer: D
NFPA 1002: N/A
Page: 258
2. What liquid is used to measure vacuum due to its density?
A. 2-propanol
B. Glycerol
C. Water
D. Mercury - ✔✔✔-answer: D
NFPA 1002: 10.2.1, 10.2.1(A)
Page: 324
2. What should the driver/operator do if the fire apparatus does not go into the "pump"
position after completing the correct procedures?
A. Manually shift the pump gear.
B. Force the transmission into third gear.
C. Reset the parking brake.
D. Reverse the procedure to take the fire apparatus out of "pump" gear and start again. - ✔✔✔-
answer: D
NFPA 1002: 4.3.7, 4.3.7(A), 5.2.4(1), 5.2.4(2), 5.2.4(3), 5.2.4(4), 5.2.4(A)
Page: 292
2.5 inch - ✔✔✔-Which size of medium- diameter fire hose is most often used for heavy interior
attack lines?