FDNY S17 Commercial Cooking Wet Chemical Fire
Extinguishing Systems Exam||Verified Questions and
Correct Answers with EXPLANATIONS||Newest
Exam!!.pdf
When ordinary combustible materials like wood, cloth,
paper, rubber, or even some plastics, are used to fuel a
fire, it would be deemed as a _________ fire. - Answer-
Class A
As a general practice, during a fire, occupants in non-
affected areas may be safest if they __________. -
Answer-Remain in place at their present location and
listen for announcements
The water flow alarms of a standpipe system must be
tested ____________. (Refer to the Reference material) -
Answer-Quarterly
What would be described as a continuous and
unobstructed path of vertical and horizontal egress travel
form any occupied portion of a building, structure or
premises to a public way, consisting of the exit access, the
exit, and the exit discharge: - Answer-Means of egress
,2|Page
The fire alarm system on the 15th floor is unable to
function in compliance with the building code. In this case,
the FLS Director should promptly notify: - Answer-The
tenants occupying the 15th floor
Portable fueled equipment must be stored outdoors,
unless it is stored in an FDNY approved indoor storage
area. If not, which of the following cannot be used
indoors? - Answer-- Weed trimmers and lawn movers
- Portable generators and power washers
- Snow blowers
What color tag would be placed at the main control valve
to indicate that a fire protection system has been restored
back to normal service? The system is fully operational
and free of any defects. - Answer-Green
Fire Life Safety Directors are required to provide a
refresher staff training session in an R-1 occupancy how
often? - Answer-1 hour quarterly on each shift
, 3|Page
Which of the statements listed below is NOT a proper
objective of scheduling fire drills for the benefit of the
occupants? - Answer-To provide proper education as part
of a one-time only employee educational session.
Which of the following describes a space within a building
that is enclosed by smoke barriers on all sides, including
the top and bottom floors. This type of system is currently
required in any existing office building over 100 feet in
height. - Answer-Smoke compartment
There may be circumstances when an alarm has been
transmitted on the premises due to a lack of maintenance,
improper detector placement, computer console
malfunction and/or improper system installation. This type
of alarm is called an: - Answer-Un-warranted alarm
Your Fire Alarm Control Panel sends you a trouble signal
indicating that your 4th floor intelligent smoke detector is
dirty and needs to be cleaned or changed. As the FLS
Director what should you do first? - Answer-Notify an
FDNY approved smoke detector company.