NEIEP 500 FINAL QUESTIONS WITH VERIFIED
ANSWERS
Ground (515 pg. 26) - Answers - What does the symbol shown below represent?
3 (555 pg. 26) - Answers - How many turns of safety rope must remain on the safety
drum after a rated load and rated speed test of a winding drum operated safety?
rail jack bolts (555 pg. 16) - Answers - Proper adjustment of which of the following can
reduce the effects of building compression on an elevator installation?
Liquidtight Flexible Metal Conduit (505 pg. 6) - Answers - What type of flex would be
used to pipe a switch in a wet location?
door clutch (530 pg. 30) - Answers - Which of the following components is used to
engage and couple the car door to the hoistway door during opening and closing?
100 feet (510 pg. 10) - Answers - On high rise of raceways, the wires must be
supported at least how many feet?
#14 (505 pg. 36) - Answers - What is the minimum size wire allowed be code for wiring
100 VAC lighting circuits to elevator cars?
raceway (505 pg. 1) - Answers - What is the metal enclosure that furnishes protection
for electrical wire called?
42 inches - Answers - What is the minimum height of a barricade placed around as
open hoistway?
360 degrees - Answers - When bending conduit, what is the maximum number of bends
in degrees between access points?
proximity devices (535 pg. 23) - Answers - Which of the following would be used to
automatically reopen the doors without physical contact of power operated vertically
sliding freight elevator doors?
It must be tamper proof to prevent override of the door contacts (535 pg. 9) - Answers -
Which of the following is a requirement that must be met when interlocks are installed
on freight elevators?
ANSWERS
Ground (515 pg. 26) - Answers - What does the symbol shown below represent?
3 (555 pg. 26) - Answers - How many turns of safety rope must remain on the safety
drum after a rated load and rated speed test of a winding drum operated safety?
rail jack bolts (555 pg. 16) - Answers - Proper adjustment of which of the following can
reduce the effects of building compression on an elevator installation?
Liquidtight Flexible Metal Conduit (505 pg. 6) - Answers - What type of flex would be
used to pipe a switch in a wet location?
door clutch (530 pg. 30) - Answers - Which of the following components is used to
engage and couple the car door to the hoistway door during opening and closing?
100 feet (510 pg. 10) - Answers - On high rise of raceways, the wires must be
supported at least how many feet?
#14 (505 pg. 36) - Answers - What is the minimum size wire allowed be code for wiring
100 VAC lighting circuits to elevator cars?
raceway (505 pg. 1) - Answers - What is the metal enclosure that furnishes protection
for electrical wire called?
42 inches - Answers - What is the minimum height of a barricade placed around as
open hoistway?
360 degrees - Answers - When bending conduit, what is the maximum number of bends
in degrees between access points?
proximity devices (535 pg. 23) - Answers - Which of the following would be used to
automatically reopen the doors without physical contact of power operated vertically
sliding freight elevator doors?
It must be tamper proof to prevent override of the door contacts (535 pg. 9) - Answers -
Which of the following is a requirement that must be met when interlocks are installed
on freight elevators?