A chiller with a charge of 200 pounds of an ozone-depleting refrigerant
has passed the initial verification leak test. When must a follow-up
verification test be conducted? - ANSWER ->Within 10 days


Why are some hydrofluoroolefin (HFO) refrigerants classified as "A2L"?
- ANSWER ->They are less flammable than hydrocarbon refrigerants,
but most are still mildly flammable


To determine if the system is leaking more than the allowed rate, the
EPA allows the use of which one of the following methods to determine
the full charge? - ANSWER ->Use of calculations based on component
and pipe sizes


When could a reciprocating compressor be damaged if energized? -
ANSWER ->When the discharge service valve is closed


Which of the following are included in EPA's definition of a "small
appliance"? - ANSWER ->Products manufactured, fully charged and
hermetically sealed in a factory

,Recovering refrigerant from a system in the vapor phase will minimize
the loss of which of the following? - ANSWER ->Oil


Which of the following is an indicator of a leak in a high-pressure
system with a capillary tube? - ANSWER ->Excessive superheat


A typical setting for the high-pressure cut-out control on a recovery unit
used for evacuating the refrigerant from a low-pressure chiller is: -
ANSWER ->10 psig


When is it essential to take measures to help release trapped CFC,
HCFC, or HFC refrigerant from the compressor oil during refrigerant
recovery? - ANSWER ->When using self-contained recovery devices


Excessive running of a purge system on a low-pressure chiller generally
indicates what condition? - ANSWER ->Leaking system


Which of the following always falls under the EPA definition for "major
maintenance, service, or repair"? - ANSWER ->Replacing a compressor

,What effect will low ambient temperatures have on recovery? -
ANSWER ->Increase the recovery time What should be used to remove
ice from sight glasses or viewing glasses? - ANSWER ->An alcohol spray


After installation of a field piped split system, the unit should first be
pressurized with: - ANSWERnitrogen and leak checked


Pressure relief valves can only be installed: - ANSWER ->in parallel


How many access valves are needed to recover the refrigerant on a
sealed system with an operating compressor that has a completely
restricted capillary tube? - ANSWER ->Only one access valve, on the
high side of the system


What is the state of the refrigerant entering the compressor of a
refrigerant system? - ANSWER ->Low pressure vapor


When first inspecting a hermetic system known to be leaking, you
should look for: - ANSWER ->traces of oil


Why should low and high side access valves be installed when
recovering refrigerant from a household refrigerator? - ANSWER ->To
improve speed of recovery

, What is the Montreal Protocol? - ANSWER ->An international treaty
that addresses ozone-depleting substances and their alternatives


A rupture disc on a recovery vessel for low-pressure refrigerants
relieves at: - ANSWER ->15 psig


What must be done before disposing of any appliance containing a CFC,
HCFC, or HFC refrigerant? - ANSWER ->Recover the refrigerant


What must a system owner do once the threshold leak rate has been
exceeded on any low-pressure system using an ozone-depleting
refrigerant? - ANSWER ->Repair the appliance enough to bring the leak
rate below the threshold, retrofit, or retire the appliance


What may be done to speed the recovery process and ensure that all
CFC, HCFC, or HFC refrigerant has been removed from a frost-free
refrigerator? - ANSWER ->Turn on the defrost heater to increase the
refrigerant's temperature and vaporize any liquid


When using a self-contained recovery device on a CFC, HCFC, or HFC
system with an operating compressor, technicians must: - ANSWER
>either recover the refrigerant to 4 inches of mercury vacuum or 90%
of the nameplate charge

Geschreven voor

Instelling
EPA 608
Vak
EPA 608

Documentinformatie

Geüpload op
3 mei 2026
Aantal pagina's
39
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
LeeErickson
1.5
(2)

Maak kennis met de verkoper

Seller avatar
LeeErickson Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
10
Lid sinds
1 jaar
Aantal volgers
0
Documenten
3194
Laatst verkocht
5 dagen geleden

1.5

2 beoordelingen

5
0
4
0
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen