A+ Grade
CSST is:
- correct answer Corrugated Stainless Steel Tubing
The Standards of Practice for home inspections:
- correct answer Defines what is and what is not included in a standard home inspection
The inspector is NOT required to:
- correct answer Operate main shut-off valves
What is flashing?
- correct answer Material that covers exposed edges of roofing where it meets chimneys or sidewalls to
prevent water intrusion.
What deficiency would cause the replacement of a forced-air gas furnace?
- correct answer Crack in the heat exchanger
Blisters and bubbles on a built-up roof usually indicate:
- correct answer That there is moisture trapped between the felt-plies
The standards of practice:
- correct answer Help to limit the liability of a home inspector
What is the minimum clearance from combustibles for a single wall furnace vent?
- correct answer 6"