Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

OIL HEAT EXAM LATEST ACTUAL EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR VERIFIED|| ||BRANDNEW!!!||

Beoordeling
-
Verkocht
-
Pagina's
41
Cijfer
A+
Geüpload op
04-05-2026
Geschreven in
2025/2026

OIL HEAT EXAM LATEST ACTUAL EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR VERIFIED|| ||BRANDNEW!!!||

Instelling
OIL HEAT
Vak
OIL HEAT

Voorbeeld van de inhoud

1|Page


OIL HEAT EXAM LATEST 2026-2027 ACTUAL EXAM WITH COMPLETE
QUESTIONS AND CORRECT DETAILED ANSWERS (100% VERIFIED
ANSWERS) |ALREADY GRADED A+| ||PROFESSOR VERIFIED||
||BRANDNEW!!!||

What must be done with any unused openings of an oil tank? -
ANSWER-made vapor tight



All oil tanks over 10 gallons must have an open air vent pipe and
a minimum pipe size of? - ANSWER-1 1/4



All oil tanks with fill and vent pipes must have what type of
gauging ? - ANSWER-Visual and Audible



Vent pipe must terminate at least how many feet above grade? -
ANSWER-3 ft or above the highest snow level



Massachusetts flash point is - ANSWER-115 F



Massachusetts flame point is - ANSWER-635F

,2|Page


Your vent pipe must terminate _______ feet vertically and ____
feet horizontally from any building opening - ANSWER-2ft, 2ft



What must vent pipe have on the termination outside building? -
ANSWER-Water tight cap



Fill and vent pipes are slopped in which direction - ANSWER-
Towards tank



Are fixed sash (no openings) windows considered a building
opening to apply to fill and vent piping? - ANSWER-No



A space supplying air for combustion whose volume is less than
50 cubic feet per 1000 BTU per hour input of all appliances in the
space. - ANSWER-Confined space



What is the maximum voltage used for oil burner circuit -
ANSWER-150 Volts

,3|Page


Piping used for oil burner oil lines ( except for conversion range
burners) shall not be smaller than what size? - ANSWER-3/8 inch
nominal pipe or tubing



What is the exception to not using compression fittings on oil
supply lines? - ANSWER-Gauge able 2 ferrule swage type fittings



Before an oil tank is removed, is a permit need to be obtained? -
ANSWER-Yes



Can Teflon tape be used on an oil supply lines - ANSWER-No



Are compression fittings acceptable on oil supply lines -
ANSWER-No



Is a draft control damper required - ANSWER-Yes



Does oil tank under 10 gallons used with an oil burner need an oil
permit? - ANSWER-No

, 4|Page


Outside oil tanks must be mounted on what? - ANSWER-A slab 4
inch thick and extends 8 inch all around tank with one pour



Why would all the piping need to come off the top of the tank -
ANSWER-Any tank that may freeze



An oil tank of more than 60 gallons other than outside above
ground tank must have what kind of cover - ANSWER-Metal cover
identifying as fuel oil fill



Visual or audible level indicators devices located inside building
must not what - ANSWER-Discharge oil or vapors into the
building



When can't a gauge glass be used on an oil tank - ANSWER-
Never because it may break causing spills



Individual supply tanks larger than 660 gallons capacity required
enclosure shall be? - ANSWER-2-hour fire rated with opening
protection

Geschreven voor

Instelling
OIL HEAT
Vak
OIL HEAT

Documentinformatie

Geüpload op
4 mei 2026
Aantal pagina's
41
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$25.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
GRADELOOMEXAMS

Maak kennis met de verkoper

Seller avatar
GRADELOOMEXAMS Chamberlain College of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
5
Lid sinds
3 maanden
Aantal volgers
0
Documenten
1150
Laatst verkocht
3 weken geleden
RELIABLE TUTOR

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen