FDNY S12 EXAM STUDY GUIDE 2026/2027 ACCURATE QUESTIONS WITH CORRECT DETAILED SOLUTIONS || 100% GUARANTEED PASS NEWEST VERSION 1. Unlawful to be installed - ANSWER Devices that give the physical appearance of fire protection equipment (ex. CCTV sprinkler head) 2. Minimum amount of time records must be kept - ANSWER 3 years 3. Hydro static test must be performed - ANSWER Every 5 years 4. System fully out of service - ANSWER Tag/red Disc/White 5. System partially out of service - ANSWER Tag/Red. Disc/Blue 6. System free from defects - ANSWER Tag/Green. Disc/N/A 7. S12/S15 holder may perform - ANSWER Visual inspections, proper notifications and record inspection results 8. S12/S15 with Q99/01 May perform - ANSWER Visual inspections, test notification appliances, perform daily and weekly routine maintenance and record inspection results 9. MFSPC - ANSWER Master fire suppression piping contractor 10. MP - ANSWER Master plumber 11. MFSPC w/s12/15 can - ANSWER Inspect, test, maintain and repair/replace system components 12. MP with S12/15 can only work on - ANSWER Residential with 30 sprinkler heads or less and no booster pump 13. Deluge system - ANSWER All sprinkler heads are open, pipes dry 14. ELO extra large orifice sprinkler - ANSWER Orifice size greater than 1" 15. Extended coverage sprinklers head - ANSWER Covers max 400sqft in light hazard and 144sqft for high hazard areas 16. RTI of a standard sprinkler - ANSWER 80 17. Sprinkler system with open heads - ANSWER Deluge system 18. Freezing point of antifreeze solutions - ANSWER Hydrometer or refractometer 19. Color required for sprinkler and standpipe risers per local law 58/2009 - ANSWER Yellow 20. Distance for hanger assembly to center line of an upright sprinkler head - ANSWER 3 inches 21. Location of the automatic ball drip - ANSWER Between lower check valve and fire department connection 22. Purpose of a ball drip - ANSWER To prevent freezing in the line 23. Build up of foreign matter on a sprinkler head - ANSWER Loading 24. When a sprinkler head opens - ANSWER It is said to be fused 25. Minimum air pressure inside a pressure tank - ANSWER 75 psi 26. Height a gravity tank should be above highest sprinkler heads it supplies - ANSWER 25 feet 27. Frequency for replacing gauges - ANSWER Every 5 years 28. Number of spare sprinkler heads required when under 300 sprinklers - ANSWER 6 29. Number of spare sprinkler heads required when there are 300 to 1000 sprinklers - ANSWER 12 30. Number of spare sprinkler heads required when there are over 1000 sprinklers - ANSWER 24 31. Year all sprinklers prior to which shall be replaced - ANSWER 1920 32. GPM at which house pumps fill the gravity tank - ANSWER 65 gpm 33. Spray pattern of a sprinkler 3 feet below the sprinkler head deflector - ANSWER 16 feet at 15 gpm 34. Notification time to FDNY for an out of service condition - ANSWER 8 hours 35. Who must draw a hand drawn sketch of the compactor system - ANSWER Certificate of fitness holder 36. Upright Sprinkler - ANSWER A sprinkler designed to be installed in such a way that the water spray is directed upwards against the deflector. 37. Water Spray Fixed System - ANSWER A special fixed pipe system connected to a reliable fire protection water supply and equipped with water spray nozzles for specific water discharge and distribution over the surface or area to be protected. The piping system is connected to the water supply through an automatically or manually actuated valve that initiates the flow of water. An automatic valve is actuated by operation of automatic detection or manual release equipment installed in the same areas as the water spray nozzles. (In special cases, the automatic detection system may also be located in another area.) 38. PREACTION SPRINKLER SYSTEMS - ANSWER designed for situations where there is danger of serious water damage. Water damage is usually caused by damaged sprinklers or broken piping. Under normal conditions there is no water in the piping. The air in the piping may or may not be is under pressure. A preaction valve prevents the water from entering the system. The valve is automatically opened when a fire detection system discovers that there is a fire or smoke condition. The preaction valve is tripped by the fire detection system before any of the sprinkler heads open. A supervisory device signals when the valve is opened. The preaction valve can also be operated manually. 39. DELUGE SPRINKLER SYSTEMS - ANSWER equipped with open sprinkler heads designed to wet down an entire area involved in a fire. This system is needed when there is danger of a fire rapidly spreading throughout the building. The deluge system will slow down the spread of the fire. Deluge systems are suitable for hazardous occupancies. This includes buildings in which flammable liquids or other hazardous materials are handled or stored. The sprinkler heads in the deluge system are open at all times. Under normal conditions there is no water in the piping. The air in the piping is not under pressure. A closed control valve prevents water from flowing into the system. A fire detection device automatically opens the control valve when a fire is identified. A supervisory device signals when the valve is opened. When the valve is opened water flows into the system. The water is then discharged out all of the sprinkler heads. The water control valve may also be opened manually. 40. NON-AUTOMATIC DRY SPRINKLER SYSTEMS - ANSWER ll pipes are normally dry. Water is supplied when needed by pumping water into the system through the Fire Department connection. Some of these systems are supplied by manual operation of a water control valve and may be equipped with sprinklers with or without fusible links. There are several non-automatic systems: 1) Perforated pipe systems - a single line of piping drilled at intervals for water discharge. These systems are usually found in basements or other areas difficult to reach in fire fighting operations. 2) Open fixed spray nozzles for transformer vaults or other hazardous areas; 3) exterior exposure sprinklers (or window sprinklers) use open sprinkler heads to form an external water curtain on the walls of a building, and 4) Foam supply systems are used for the protection of special hazardous occupancies.

Meer zien Lees minder
Instelling
FDNY S12
Vak
FDNY S12

Voorbeeld van de inhoud

FDNY S12 EXAM STUDY GUIDE 2026/2027
ACCURATE QUESTIONS WITH CORRECT
DETAILED SOLUTIONS ||
100% GUARANTEED PASS
<NEWEST VERSION>


1. Unlawful to be installed - ANSWER ✔ Devices that give the physical
appearance of fire protection equipment (ex. CCTV sprinkler head)

2. Minimum amount of time records must be kept - ANSWER ✔ 3 years

3. Hydro static test must be performed - ANSWER ✔ Every 5 years

4. System fully out of service - ANSWER ✔ Tag/red Disc/White

5. System partially out of service - ANSWER ✔ Tag/Red. Disc/Blue

6. System free from defects - ANSWER ✔ Tag/Green. Disc/N/A

7. S12/S15 holder may perform - ANSWER ✔ Visual inspections, proper
notifications and record inspection results

8. S12/S15 with Q99/01 May perform - ANSWER ✔ Visual inspections, test
notification appliances, perform daily and weekly routine maintenance and
record inspection results

9. MFSPC - ANSWER ✔ Master fire suppression piping contractor

10.MP - ANSWER ✔ Master plumber

11.MFSPC w/s12/15 can - ANSWER ✔ Inspect, test, maintain and
repair/replace system components

,12.MP with S12/15 can only work on - ANSWER ✔ Residential with 30
sprinkler heads or less and no booster pump

13.Deluge system - ANSWER ✔ All sprinkler heads are open, pipes dry

14.ELO extra large orifice sprinkler - ANSWER ✔ Orifice size greater than 1"

15.Extended coverage sprinklers head - ANSWER ✔ Covers max 400sqft in
light hazard and 144sqft for high hazard areas

16.RTI of a standard sprinkler - ANSWER ✔ 80

17.Sprinkler system with open heads - ANSWER ✔ Deluge system

18.Freezing point of antifreeze solutions - ANSWER ✔ Hydrometer or
refractometer

19.Color required for sprinkler and standpipe risers per local law 58/2009 -
ANSWER ✔ Yellow

20.Distance for hanger assembly to center line of an upright sprinkler head -
ANSWER ✔ 3 inches

21.Location of the automatic ball drip - ANSWER ✔ Between lower check
valve and fire department connection

22.Purpose of a ball drip - ANSWER ✔ To prevent freezing in the line

23.Build up of foreign matter on a sprinkler head - ANSWER ✔ Loading

24.When a sprinkler head opens - ANSWER ✔ It is said to be fused

25.Minimum air pressure inside a pressure tank - ANSWER ✔ 75 psi

26.Height a gravity tank should be above highest sprinkler heads it supplies -
ANSWER ✔ 25 feet

,27.Frequency for replacing gauges - ANSWER ✔ Every 5 years

28.Number of spare sprinkler heads required when under 300 sprinklers -
ANSWER ✔ 6

29.Number of spare sprinkler heads required when there are 300 to 1000
sprinklers - ANSWER ✔ 12

30.Number of spare sprinkler heads required when there are over 1000
sprinklers - ANSWER ✔ 24

31.Year all sprinklers prior to which shall be replaced - ANSWER ✔ 1920

32.GPM at which house pumps fill the gravity tank - ANSWER ✔ 65 gpm

33.Spray pattern of a sprinkler 3 feet below the sprinkler head deflector -
ANSWER ✔ 16 feet at 15 gpm

34.Notification time to FDNY for an out of service condition - ANSWER ✔ 8
hours

35.Who must draw a hand drawn sketch of the compactor system - ANSWER
✔ Certificate of fitness holder

36.Upright Sprinkler - ANSWER ✔ A sprinkler designed to be installed in
such a way that the water spray is directed upwards against the deflector.

37.Water Spray Fixed System - ANSWER ✔ A special fixed pipe system
connected to a reliable fire protection water supply and equipped with water
spray nozzles for specific water discharge and distribution over the surface
or area to be protected. The piping system is connected to the water supply
through an automatically or manually actuated valve that initiates the flow of
water. An automatic valve is actuated by operation of automatic detection or
manual release equipment installed in the same areas as the water spray
nozzles. (In special cases, the automatic detection system may also be
located in another area.)

, 38.PREACTION SPRINKLER SYSTEMS - ANSWER ✔ designed for
situations where there is danger of serious water damage. Water damage is
usually caused by damaged sprinklers or broken piping. Under normal
conditions there is no water in the piping. The air in the piping may or may
not be is under pressure. A preaction valve prevents the water from entering
the system. The valve is automatically opened when a fire detection system
discovers that there is a fire or smoke condition. The preaction valve is
tripped by the fire detection system before any of the sprinkler heads open.
A supervisory device signals when the valve is opened. The preaction valve
can also be operated manually.

39.DELUGE SPRINKLER SYSTEMS - ANSWER ✔ equipped with open
sprinkler heads designed to wet down an entire area involved in a fire. This
system is needed when there is danger of a fire rapidly spreading throughout
the building. The deluge system will slow down the spread of the fire.
Deluge systems are suitable for hazardous occupancies. This includes
buildings in which flammable liquids or other hazardous materials are
handled or stored.
The sprinkler heads in the deluge system are open at all times. Under normal
conditions there is no water in the piping. The air in the piping is not under
pressure. A closed control valve prevents water from flowing into the
system. A fire detection device automatically opens the control valve when a
fire is identified. A supervisory device signals when the valve is opened.
When the valve is opened water flows into the system. The water is then
discharged out all of the sprinkler heads. The water control valve may also
be opened manually.

40.NON-AUTOMATIC DRY SPRINKLER SYSTEMS - ANSWER ✔ ll
pipes are normally dry. Water is supplied when needed by pumping water
into the system through the Fire Department connection. Some of these
systems are supplied by manual operation of a water control valve and may
be equipped with sprinklers with or without fusible links.
There are several non-automatic systems: 1) Perforated pipe systems - a
single line of piping drilled at intervals for water discharge. These systems
are usually found in basements or other areas difficult to reach in fire
fighting operations. 2) Open fixed spray nozzles for transformer vaults or
other hazardous areas; 3) exterior exposure sprinklers (or window sprinklers)
use open sprinkler heads to form an external water curtain on the walls of a

Geschreven voor

Instelling
FDNY S12
Vak
FDNY S12

Documentinformatie

Geüpload op
4 mei 2026
Aantal pagina's
97
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ProfBenjamin Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
639
Lid sinds
1 jaar
Aantal volgers
17
Documenten
3831
Laatst verkocht
4 uur geleden
EXCELLENT ACHIEVERS LIBRARY

As a professional tutor, I provide exceptional assistance with homework, quizzes, and exams across various subjects, including Psychology, Nursing, Biological Sciences, Business, Engineering, Human Resource Management, and Mathematics. I am dedicated to offering high-quality support and ensuring that all work meets scholarly standards. To enhance the effectiveness of our services, I work with a team of experienced tutors to create comprehensive and effective revision materials. Together, we are committed to helping students achieve excellent grades through our collaborative efforts and expertise.

Lees meer Lees minder
3.8

135 beoordelingen

5
63
4
18
3
33
2
9
1
12

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen