FULL QUESTIONS AND VERIFIED 100%
CORRECT ANSWERS GRADED A+
◉ AS. Answer: Automation Station, software representation of Desigo
DXR controller
◉ ASHRAE. Answer: American Society of Heating, Refrigerating and
Air-Conditioning Engineers. An HVAC industry organization for
advancing the arts and sciences of heating, refrigeration, air
conditioning, and ventilation for the benefit of the public.
◉ ALN. Answer: Field Panel (BACnet IP over Ethernet or BACnet
MS/TP over EIA-485 network consisting of the TC Modular Series and
TC Compact Series. May also contain TALON AX Workstation, Desigo
CC or Siemens N4 Workbench
◉ ANSI. Answer: American National Standards Institute.
◉ Application Protocol Data Unit (APDU). Answer: A unit of data
specified in an application protocol and consisting of application-
protocol-controlinformation and possibly application-user-data (ISO
9545).
,◉ Application MC (AppMC). Answer: Application MC (Monitor &
Control) is a FIN Builder Project that contains Navigation Tree and
applications graphics for many of the available MS/TP FLN devices.
Application MC is accessible through a web browser and can be only
deployed to a TC-36 or TC-Modular field panel.
◉ B-BC. Answer: BACnet Building Controller Profile (B-BC) BACnet
defines a B-BC as a general-purpose, field-programmable device
capable of carrying out a variety of building automation and control
tasks. It also a supervisory controller to BASC and B-AAC., which
means it can schedule, trend and alarm points from these devices
◉ B-AWS. Answer:
◉ B-OWS. Answer: BACnet Operator Workstation Profile (B-OWS)
BACnet defines a B-OWS as "the operator's window into a BACnet
system." Primarily used for on-line operations, it is designed to provide
an operator with all the information and editing ability they need to
manage a system on a daily basis. Operator Workstation can display
trends, schedules, and other specialized objects. It also provides the user
the capability to acknowledge alarms, along with a summary of alarms.
◉ BACnet. Answer: ASHRAE Building Automation and Control
Networking data communication protocol for Building Automation and
Control networks, based on specifications detailed in ANSI/ASHRAE
Standard 135. The first version of this standard was published in 1995 as
ANSI/ASHRAE Standard 135-1995. The latest published version of this
, standard (published in 2012) is ANSI/ASHRAE Standard 135-2012.
BACnet allows devices from multiple manufacturers to communicate
and work together.
◉ BACnet Application Specific Controller Profile (B-ASC). Answer:
BACnet defines a B-ASC is a controller with limited resources relative
to a B-AA. It is intended for use in a specific application and supports
limited programmability. It able to share values of any of its BACnet
objects and allows modification of some or all of its BACnet objects by
another device.
◉ BACnet Broadcast Management Device (BBMD). Answer: The
functionality of BBMDs is to relay messages across large networks
through routers. It's a BACnet operation such as dynamic device binding
rely on broadcast messages that are received by every BACnet device on
a local segment, and in some cases across segments or globally within
the whole BACnet internetwork. Because of how IP handles routing,
broadcasts cannot cross IP subnets. In situations when there are multiple
IP subnets with BACnet/IP devices, special device functionality is
required to deliver broadcasts to all members of a multi-subnet
community. BBMDs fill this role.
◉ BACnet Device. Answer: A BACnet device is a microprocessor-based
unit that uses the BACnet protocol for interoperable communication.
◉ BACnet Device ID. Answer: A number, between 0 and 4,194,302,
assigned to a BACnet device by the person configuring a BACnet