ACI Certification- Concrete Field Testing
Technician Grade 1 CP-1 (12) /159
Questions And Answers 2025


After the final rodding, the sides of the slump mold should be tapped lightly
with the tamping rod. True or False? - ANSWER
>>False

When raising the slump mold, it should not be rotated or twisted. True or
False? -
ANSWER>>True

How much time is allowed for lifting the slump mold? - >>5 ±
ANSWER2
seconds

The measurement for slump is made from the top of the mold to what point
of the concrete specimen? - >>The displaced original center of
ANSWER
the top surface of the specimen

The slump of the concrete is measured and reported to the nearest _____.
- ANSWER>>¼ in. [5 mm]

How much time is allowed to conduct the slump test from beginning to
completion? - >>2½ minutes
ANSWER

ASTM C138 - >>Standard Test Method for Density (Unit Weight),
ANSWER

,Yield, and Air Content (Gravimetric) of Concrete

The diameter of the tamping rod used in this test method is _____ . -
ANSWER >>⅝ in. [16
mm]

What is the required shape of the tamping end of the rod? -
ANSWER >>Rounded to a hemispherical
tip

What is the required minimum frequency of the vibrator used in this test
method? - >>7000 vibrations per minute
ANSWER

The outside diameter or side dimension of the vibrating element must be at
least _____ but not greater than _____ . - >>0.75 in. [19
ANSWERmm],
1.50 in. [38 mm]

A plastic container can be used for the measure in this method. True or
False? - >>False, measure must be steel or other suitable metal
ANSWER

What is the minimum thickness of a metal strike-off plate? - >>¼
ANSWER
in. [6 mm]

What is the minimum thickness for a glass or acrylic strike-off plate? -
ANSWER >>½ in. [12
mm]

What is the specified weight of the mallet used on measures that are 0.5 ft3
[14 L] or smaller? - ANSWER >>1.25 ± 0.50 lb. [600 ± 200 g]

Measures other than air meter bowls used for this test must conform to

, ASTM _____. - >>C29
ANSWER

Air meter bowls used for this test must conform to ASTM _____ and be
calibrated for volume according
to ASTM _____. - >>C231,
ANSWERC29

The concrete sample must be obtained in accordance with what ASTM
method? - >>C172
ANSWER

What method of consolidation must be used when the slump is greater than
3 in. [75 mm]? - >>Rodding
ANSWER

What method of consolidation must be used when the slump is less than 1
in. [25 mm]? - ANSWER
>>Vibration

If rodding is the method of consolidation being used, the measure must be
filled in how many layers? -
ANSWER>>3

For a measure of 0.5 ft3 [14 L], what is the required number of strokes of
the tamping rod for consolidation of each layer? - ANSWER>>25

When rodding the middle and the top layers, the tamping rod should
penetrate into the layer below approximately _____. - ANSWER>>1 in. [25
mm]

If vibration is the method of consolidation, the measure must be filled in
_____ approximately equal layers. - ANSWER
>>2

Geschreven voor

Instelling
Aci concrete
Vak
Aci concrete

Documentinformatie

Geüpload op
7 mei 2026
Aantal pagina's
20
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
LeeErickson
1.5
(2)

Maak kennis met de verkoper

Seller avatar
LeeErickson Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
10
Lid sinds
1 jaar
Aantal volgers
0
Documenten
3234
Laatst verkocht
1 week geleden

1.5

2 beoordelingen

5
0
4
0
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen