REVIEW SOLVED QUESTIONS WITH
ACCURATE ANSWERS
●● When a door is opened, fast air moving in at the bottom of the
opening and smoke moving out on top indicates that you should: (918)
A. open the door fully to cool down the environment.
B. keep the door closed and find another point of entry.
C. open the door slightly and apply water to the hot gas layer.
D. keep the door closed until another ventilation point is made
Answer: C. open the door slightly and apply water to the hot gas layer.
●● As a crew leader, which type of progress report might you have to
provide to the Incident Commander after a change in strategies and
tactics at the scene? (919)
A. Arrival report
B. Hazard report
C. Tactical progress report
D. Personnel accountability report
Answer: D. Personnel accountability report
●● As a crew leader, you might have to provide a - that might put your
firefighters at risk. (919)
,A. PAR signal
B. hazard report
C. tactical progress report
D. Tactical withdrawal signal
Answer: B. hazard report
●● What should you do if you are leading the ventilation crew on the
roof of a building and you hear multiple audible devices going off?
(919)
A. Listen to the radio traffic for any specifications
B. Cease operations and follow SOPs for evacuation signals
C. Ask the Incident Commander which company just arrived on scene
D. Continue your task without questioning, because this signal is only
for interior crews
Answer: B. Cease operations and follow SOPs for evacuation signals
●● Search and rescue teams must take a of those being rescued. (921)
A. thermal imager
B. charged hoseline
C. forcible entry tool
D. tag line or a RIC bag
Answer: B. charged hoseline
,●● connecting the supply line to a hydrant, which hose appliance
enables the hydrant to have a second hose connected without shutting off
the hydrant? (913)
A. Gate valve
B. Water thief
C. Wye appliance
D. Siamese appliance
Answer: A. Gate valve
●● Which hose appliance is also known as a Portable fire hydrant and is
useful when a pumper is not available? (913)
A. Fittings
B. Water thief
Which hose appliance is also known as a Portable fire hydrant and is
useful when a pumper is not available? (913)
A. Fittings
B. Water thief
C. LDH appliance
D.Siamese appliance
Answer: C. LDH appliance
●● A____ must be used with caution and coordination because it can
change the pressure and flow path inside the building.
, path inside the building. (915)
A. solid stream
B. broken stream
C. straight stream
D. wide fog pattern
Answer: D. wide fog pattern
●● As a crew leader, if you ask your firefighter to cool the hot gas layer
or apply water to the seat of the fire, he or she should use a stream. (915)
A. fog or solid
B. fog or straight
C. solid or broken
D. straight or broken
Answer: D. straight or broken
●● would be used when the chosen tactic is to apply water through an
opening at the compartment lining, causing the stream to disperse into
droplets and absorb more heat? (915)
A. Fog nozzle or wide stream
B. Fog nozzle or straight stream
C. Straight stream from a Breslin nozzle
D. Solid stream from a smooth bore nozzle
Answer: D. Solid stream from a smooth bore nozzle