Section 1: Electrical Trades (Questions 1–12)
1. In a residential 120V circuit, what is the maximum allowable voltage drop
for a branch circuit per NEC 2026?
A) 1%
B) 3%
C) 5%
D) 10%
*Rationale: NEC 2026 recommends 3% max for branch circuits and 5% total
(feeder + branch).*
2. What color insulation is mandatory for the grounded neutral conductor in a
480V system?
A) Green
B) Black
C) White or Gray
D) Yellow
Rationale: NEC requires white or gray for grounded neutral conductors regardless
of voltage.
,3. A ground fault circuit interrupter (GFCI) must trip within ______ when a
fault to ground occurs.
A) 10–15 seconds
B) 1–2 seconds
C) 25–40 milliseconds
D) 100–200 milliseconds
Rationale: GFCI trip time is < 40 ms for 4–6 mA fault current to prevent
electrocution.
4. Which tool is best for non-contact voltage detection on a 2026 smart panel?
A) Multimeter
B) Clamp meter
C) Non-contact voltage tester (NCVT)
D) Solenoid tester
Rationale: NCVT detects E-fields without contact; safer for quick checks.
5. The minimum bending radius for a 12 AWG THHN copper conductor is
______ times the cable diameter.
A) 4
B) 5
C) 6
D) 10
Rationale: NEC 2026 Table 2: 5x diameter for single conductors.
6. What does a “smart breaker” in a 2026 electrical panel primarily monitor?
A) Voltage only
B) Real-time power consumption and arc faults
C) Ambient temperature
D) Wire insulation age
Rationale: Smart breakers (e.g., Eaton, Leviton) track kW, kWh, and arc/series
faults.
7. Which wire gauge is required for a 30A, 240V EV charger circuit (copper)?
A) 14 AWG
B) 10 AWG
C) 8 AWG
D) 6 AWG
*Rationale: NEC Table 310.16: 10 AWG @ 60°C = 30A.*
, 8. The purpose of a bonding jumper is to:
A) Carry fault current to trip breaker
B) Ensure conductive non-current-carrying parts are at same potential
C) Reduce voltage drop
D) Increase circuit resistance
Rationale: Bonding equalizes potential to prevent shock from different metal parts.
9. A three-phase motor draws 15A per phase. Using the 2026 NEC, what is the
minimum disconnect switch rating?
A) 15A
B) 18A (115% of FLA)
C) 20A
D) 30A
*Rationale: NEC 430.110: Disconnect rating ≥ 115% of full-load current.*
10. What is the correct torque for a 10 AWG terminal lug (copper, 75°C) per
UL 486A-2026?
A) 10 in-lb
B) 25 in-lb
C) 35 in-lb
D) 50 in-lb
*Rationale: Standard torque per UL 486A for 10 AWG Cu = 25–30 in-lb.*
11. Arc flash PPE category 2 requires an arc rating of at least:
A) 8 cal/cm²
B) 12 cal/cm²
C) 25 cal/cm²
D) 40 cal/cm²
*Rationale: NFPA 70E 2026: Category 2 = 8 cal/cm².*
12. A multimeter reads 0 ohms across a switch in the OFF position. This
indicates:
A) Normal operation
B) Welded closed contacts
C) Open circuit
D) High resistance
Rationale: 0Ω in OFF means switch failed closed (dangerous).