Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

FLSD Study guide| Complete questions and verified answers| Latest 2026/2027

Rating
-
Sold
-
Pages
77
Grade
A+
Uploaded on
08-05-2026
Written in
2025/2026

FLSD Study guide| Complete questions and verified answers| Latest 2026/2027 1-Manual pull stations are red. Those in Group "B" buildings and Group "R-1" hotels have a one-inch diagonal white stripe from the top left corner to the bottom right corner. What is the meaning of the white stripe? Why are these white-striped pull stations found in "B" and "R-1" properties? Explain your answer. The white stripe indicates that when a manual pull station is activated, the fire alarm signal will be automatically sent to the Fire Alarm Control Panel, the Central Station and the Fire Department. Group "B" and "R-1" properties must have the fire alarm systems monitored by Central Stations; therefore, the fire alarm does not stay "in-house." Note: The 2008 Fire Code mandated that all buildings with fire alarm systems have central station monitoring, regardless of whether the manual pull stations have the white stripe. 2-A smoke detector is designed to detect smoke and activate a fire alarm. Why must area smoke detectors be located in elevator lobbies? Explain your answer. Area smoke detectors must be located in elevator lobbies to activate elevator recall. The elevator lobby area smoke detectors activate because there is smoke in the elevator lobby, hence the proximity of the smoke to the elevators and their occupants is prioritized and the elevators recall to the Ground Floor or lowest terminal landing to protect the elevator occupants and allow them to escape the property. When two smoke detectors are located in elevator lobbies, they must both activate to sound the alarm and recall the elevators. They are known as "cross-over smoke detectors." 3-A "sky lobby" is an upper floor where passengers must transfer from one elevator bank to another to reach the desired floor. In a two-bank building, will there be a blind shaft on the bank that services the higher floors? Yes/No? Explain your answer. No. A sky lobby exists when passengers must transfer from one elevator bank to another elevator bank to reach the desired floor. The option of getting in the high-rise bank elevators on the lobby level does not exist. Therefore, the high-rise bank elevators are not express elevators. In the high-rise bank, the space between the second floor and the sky lobby floor consists of office space. 4- The FLS Building Evacuation Supervisor is not required to hold a certificate of fitness FLS Director but must have a certificate of fitness fire guard in the event there is a torch operations job scheduled when the building has 500 people or less. True or false? Explain your answer. False. The FLS Building Evacuation Supervisor (FLS BES) is not required to hold a Certificate of Fitness of any category. Because the FLS BES must be available to respond to the Fire Alarm Control Panel when the building has 450 occupants or less and a fire alarm activates, then it is impossible for the FLS BES to oversee torch operations as a Fire Guard, even if the FLS BES did in fact have a Certificate of Fitness Fire Guard F-60. 5- The heat that is generated by the sun is transferred via radiation. Why is it not via conduction? Explain your answer. Heat transfer via conduction requires an intervening medium (direct contact) that allows the heat to transfer from point "A" to point "B." For example, a metal pipe heated at one end will eventually heat the opposite end and anything touching the pipe. There is no solid object connecting the sun to Earth. Heat transfer from the sun is via Radiation (electromagnetic waves). 6- The ball-drip valve in a fire suppression system is located on the first sub-Grade level of a building. Why is it not located on another level? Explain your answer. The Ball-Drip Valve is designed to detect when the Lower Check Valve in the system is defective or has failed completely. It is also designed to drip excess water from the pipe between the Fire Department Connection and the Lower Check Valve to prevent the water from freezing after the Fire Department disconnects the fire hoses from the Fire Department Connection. Hence, the Ball-Drip Valve must be at a level that is lower (Cellar level) than the location of the Fire Department Connections (street level). 7- aww If a FLS Director is not required to be present in a Group "B" building, then who is required to be in the building to address fire and non-fire emergencies in the absence of the FLS Director? And, what determines when a FLS Director is required to be in the building? Explain your answers. The FLS Building Evacuation Supervisor (FLS BES) is required to be in the Group "B" property when the Fire and Life Safety Director is not required to be in the property. A Fire and Life Safety Director is required to be in the property when there are more than 450 in the entire building or more than 100 people above or below the Ground Floor, excluding the Ground Floor; and during normal business hours of the building. 8- No fire alarm activation goes directly from an alarm-sending device to the Fire Department. In a fire alarm system, where do all fire alarms first report the activation of an alarm-sending device and why? Explain your answers. All automatic and manual alarm-sending (peripheral) devices first send the signal to the Fire Alarm Control Panel to alert the Fire and Life Safety Director that a fire alarm has activated. 9- Area smoke detectors are readily visible and usually appear on the ceiling level of a room. Duct smoke detectors are also designed to detect smoke. What are duct smoke detectors and why are they necessary? Explain your answer.

Show more Read less
Institution
FLSD
Course
FLSD











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FLSD
Course
FLSD

Document information

Uploaded on
May 8, 2026
Number of pages
77
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Thepassword Rasmussen College
Follow You need to be logged in order to follow users or courses
Sold
443
Member since
4 year
Number of followers
296
Documents
3411
Last sold
3 days ago

3.8

92 reviews

5
48
4
15
3
7
2
6
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions