Low airflow over a residential split system air conditioning evaporator can cause
A: Liquid flood-back to the compressor
B: A decrease in compression ratio
C: An increase in suction line superheat
D: Oil logging in the evaporator
A: Liquid flood-back to the compressor
Which of the following is the correct sequence of work?
A: Attach gauge manifold, recover refrigerant, replace filter core, evacuate the
, lOMoARcPSD| 57911371
system, recharge the system.
B: Recover refrigerant, evacuate the system, replace filter core, recharge the
system.
C: Attach gauge manifold, evacuate the system, replace filter core, recover
refrigerant, recharge the system.
D: Attach gauge manifold, recharge the system, evacuate the system, replace
filter core.
A: Attach gauge manifold, recover refrigerant, replace filter core, evacuate the system,
recharge the system.
As the pressure on a liquid is increased, the vaporization temperature of the
liquid
A: Decreases
B: Increases
C: Remains unchanged
D: Varies
B: Increases
An oil separator must be mounted
A: Level
B: Below the compressor crankcase
C: Above the compressor crankcase
D: In the suction line
A: Level
Which of the following metering devices controls evaporator pressure?
A: Thermostatic expansion valve