CSL PRACTICE EXAM QUESTIONS AND
ANSWERS GRADED A+
An institutional occupancy is typically considered Group ANS >> I USE Group
301.1 #6 IBC
A Group__________ occupancy is the general classification for miscellaneous and
utility structures. ANS >> U USE Group
301.1.10 (4) IBC
Accessory religious educational rooms need not be considered separate
occupancies where the occupant load is less than __________ occupants. ANS
>> 100
303.1, Exception #5 IBC
An accessory assembly area may be classified as a Group B occupancy where the
floor area is a maximum of__________ square feet. ANS >> 749
303.1 Exception #3 IBC
,CSL PRACTICE EXAM
In a Group E middle school, an assembly area accessory to the Group E shall be
separated at what minimum level from the remainder of the school building?
__________ ANS >> No separation is required
303.1 Exception #4 IBC
Prior to any permitted increases, the maximum allowable quantity per control
area of a Class IB flammable liquid permitted in a storage condition in a one-story
Group F-1 occupancy is __________ gallons. ANS >> 120
307.1 IBC
What types of construction are considered "non-combustible"? ANS >> I, II
602.2 IBC
Type III buildings shall have __________ exterior walls and interior elements of
__________. ANS >> Non-combustible, of any material permitted by the code
602.3 IBC
A Type IV building is also described as __________ construction. ANS >> Heavy
timber
602.4 IBC
Where supporting floor loads, wood columns of Type IV construction shall be of
this minimum nominal size: __________ inches by __________ inches. ANS >> 8
inches by 8 inches
602.4.1 IBC
, CSL PRACTICE EXAM
Where used in floor framing, wood beams of Type IV construction shall be of this
minimum nominal size: __________ inches by __________ inches. ANS >> 6
inches by 10 inches
602.4.2 IBC
In a building of Type IB construction, the minimum required fire-resistance rating
of the floor construction is __________ hour(s). ANS >> 2 hours
Table 601 IBC
In a building of Type IIIA construction, the minimum required fire-resistance rating
of the floor construction is __________ hour(s). ANS >> 2 hour
Table 601, note an IBC
Premises must be identified by numbers or addresses visible from the street, with
a minimum character height of at least __________ inches. ANS >> 4 inches
501.2 IBC
Building height is measured to the __________. ANS >> Average height of
highest roof surface
502.1 IBC
The tabular allowable height and building area per floor for a Group I-2 occupancy
of Type IB construction is __________ stories and __________ square feet. ANS
>> 4, Unlimited
503 IBC