What thickness in millimeters of pavers is used for residences?
A. .6
B. .5
C. .75
D. 63.5
Brick (paving brick, pavers). Rectangular fired clay brick with typical dimensions of 4
inches x 8 inches x 2.5 inches thick. Available in a range of colors, paving bricks have no
mortar holes and an average strength of approximately 5,000 PSI.
What is the length of a standard concrete block including the mortar joint?
A. 8 inches
B. 10 inches
C. 12 inches
D. 16 inches
Sizes are usually given in their nominal dimensions.A unit measuring 7 5/8" wide, 7 5/8"
high, and 15 5/8"long is known as an 8" x 8" x 16" unit. The mortar jointis intended to be
3/8" to fit the modular design basedon a 4" module.
,When should you seal the bottom of a piece of wood fencing?
A. If water pools under them
B. when within 5 feet of a sprinkler head
C. If there is less than 2 inches of clearance from the ground.
D. If it touches the earth
If the boards have to touch the earth, seal the board ends before you install them.
How is transplant shock avoided?
A. NEED HELP WITH THIS CHOICE
B. Anti transpirants
C. increase water
D. Fertilize
Antitranspirants, also called antidesiccants, are chemicals that reduce the amount of
water plants lose through transpiration. Antitranspirants are useful because excessive
water loss can result in transplant shock. They normally act either to induce closing of
the stomata or to cover the stomata with a water-impermeable coating.
A trench has been prepared for a gray water irrigation lines, according to the
International Residential Code, what shall be the minimum depth of the filter material
beneath the perforated line?
,A. 12 inches
B. 3 inches
C. 8 inches
D. 6 inches
Not less than 6 inches in depth of aggregate, ranging in size from 1/2 to 2-1/2 inches
(12.7 mm to 64 mm), shall be laid into the trench below the distribution piping
elevation.
A CR-21 licensee may install residential misting systems under what PSI?
A. 1000 psi
B. 120 psi
C. 90 psi
D. 500 psi
HARDSCAPING AND IRRIGATION SYSTEMS This classification allows the licensee to
install, alter, and repair:
Residential outdoor misting systems. Free standing or attached to existing
appurtenance, not more than 1000 PSI.
Blue Stake uses orange to mark which of the following?
A. Gas
, B. Electric
C. Fiber Optics, Cable, Phone
D. Sewer
Electric Power Distribution - Safety Red Gas, Oil Distribution - High Visibility Safety
Yellow Telephone, Cable, Fiber Optics - Safety Alert Orange Water Systems - Safety
Precaution Blue Sanitary Sewer Systems - Safety Green Reclaimed Water - Purple
What color is used to mark an area for locating utilities prior to excavations?
A. Green
B. White
C. Blue
D. Pink
All of the following will not decrease the water pressure in a long run of irrigation pipe
except?
A. A pipe going down hill
B. Going from a larger pipe to a smaller pipe
C. Less Sprinklers on a run
D. Going from a smaller piper to a larger pipe