GAS CFESA REVIEW STUDY QUESTIONS WITH 100% VERIFIED ANSWERS ALREADY GRADED A+ | GUARANTEE PASS 1. Where does natural gas come from? - ANSWER Found in wells drilled deep in the ground 2. Where does lp gas come from? - ANSWER It is a byproduct of natural gas 3. What are three gases often termed LP? - ANSWER Propane, butane, ethane 4. Are LP tanks filled with gas or liquid? - ANSWER Liquid 5. What happens in a LP tank as gas is drawn off? - ANSWER Pressure in the tank begins to fall and so does the boiling point. 6. To solve unusual venting problems like negative pressure, high winds, long vents, the installe should use_____? A) A larger size vent pipe B) Vent outlets C) Vent top turbines D) A draft hood - ANSWER D 7. What is a bypass flame? A) The smallest flame that will keep the burners lit after the gas thermostat has reached the temperature set point B) A flame that is 3/8" tall after the thermostat shuts off C) A flame left on the burner to keep the pilot form going out D) A flame to a special part of the burner after the main burner goes off - ANSWER A 8. The primary purpose of a vent on a regulator is to: A) Vent leaking gas B) Allow diaphragm movement C) Allow high pressure D) Monitor flow - ANSWER B 9. A properly burning infrared ceramic burner will look______? A) Blue B) Bright reddish orange C) Dull red D) Blue with a tint of orange - ANSWER B 10. Vent lines are required on regulators above 1" and must be vented: A) A pilot flame B) An open flame within 2 feet C) A working flue or exhaust system D) The outside atmosphere, above the snow line - ANSWER D 11. What is the proper flame current for an ignition module? A) Always 3 or more microamps B) Always ¼ or more microamps C) It depends on the module manufacturer D) Always 2 or more microamps - ANSWER C 12. Does natural gas have an odor? - ANSWER No 13. What is specific gravity of a gas? - ANSWER The weight of the gas compared to the weight of air, specific gravity of air is 1. Anything lower than one will float. 14. Is natural gas heavier or lighter than air? - ANSWER Lighter 15. Is LP gas heavier or lighter than air - ANSWER Heavier 16. Why is LP more dangerous to work with than natural gas? - ANSWER It is heavier than air and will fall and not dissapate 17. What is the hearing value of a cubic foot of natural gas? - ANSWER 950btus to 1150btus 18. What is the heating value of LP gas? - ANSWER 2500btus 19. How should you check for leaks? - ANSWER Soapy bubbles or combustible leak detectors 20. Which gas is more volatile, NG OR LP? - ANSWER LP 21. The purpose of a draft hood/draft diverter is_______? A) To prevent drafts from entering the burner compartment that comes from the power cent hoods. B) To prevent the combustion chamber from overheating, and allowing air to come down the vent pipe into the room. C) To allow the flue to control the amount of secondary air drawn in instead of the vent pipe, and to prevent air from coming back down the vent into the combustion chamber D) To allow the vent pipe to control the amount of secondary air drawn into the combustion chamber as designed by its height above the hood. - ANSWER C 22. The two primary functions of the flue are____? A) The remove combustion byproducts and heat from the equipment B) To create a draft to pull in secondary air and remove the byproducts form the combustion chamber C) To create a draft to keep the burners cool and remove byproducts from the cooking area D) To remove the excessive heat to keep the burners, and cooking surface from overheating - ANSWER B 23. Primary air is the air______? A) That surrounds the burner B) That enters the burner though the venture C) Is the air that is vented through the exhaust system D) That must always have a pressure greater than the incoming gas pressure - ANSWER B

Meer zien Lees minder
Instelling
GAS CFESA
Vak
GAS CFESA

Voorbeeld van de inhoud

GAS CFESA REVIEW STUDY QUESTIONS WITH
100% VERIFIED ANSWERS ALREADY GRADED
A+ | GUARANTEE PASS

1. Where does natural gas come from? - ANSWER Found in wells drilled
deep in the ground


2. Where does lp gas come from? - ANSWER It is a byproduct of natural gas


3. What are three gases often termed LP? - ANSWER Propane, butane, ethane


4. Are LP tanks filled with gas or liquid? - ANSWER Liquid


5. What happens in a LP tank as gas is drawn off? - ANSWER Pressure in the
tank begins to fall and so does the boiling point.


6. To solve unusual venting problems like negative pressure, high winds, long
vents, the installe
should use_____?
A) A larger size vent pipe
B) Vent outlets
C) Vent top turbines
D) A draft hood - ANSWER D


7. What is a bypass flame?
A) The smallest flame that will keep the burners lit after the gas
thermostat has reached the

,temperature set point
B) A flame that is 3/8" tall after the thermostat shuts off
C) A flame left on the burner to keep the pilot form going out
D) A flame to a special part of the burner after the main burner goes off -
ANSWER A


8. The primary purpose of a vent on a regulator is to:
A) Vent leaking gas
B) Allow diaphragm movement
C) Allow high pressure
D) Monitor flow - ANSWER B


9. A properly burning infrared ceramic burner will look______?
A) Blue
B) Bright reddish orange
C) Dull red
D) Blue with a tint of orange - ANSWER B


10.Vent lines are required on regulators above 1" and must be vented:
A) A pilot flame
B) An open flame within 2 feet
C) A working flue or exhaust system
D) The outside atmosphere, above the snow line - ANSWER D


11.What is the proper flame current for an ignition module?
A) Always 3 or more microamps
B) Always ¼ or more microamps
C) It depends on the module manufacturer
D) Always 2 or more microamps - ANSWER C


12.Does natural gas have an odor? - ANSWER No

,13.What is specific gravity of a gas? - ANSWER The weight of the gas
compared to the weight of air, specific gravity of air is 1. Anything lower
than one will float.


14.Is natural gas heavier or lighter than air? - ANSWER Lighter


15.Is LP gas heavier or lighter than air - ANSWER Heavier


16.Why is LP more dangerous to work with than natural gas? - ANSWER It is
heavier than air and will fall and not dissapate


17.What is the hearing value of a cubic foot of natural gas? - ANSWER
950btus to 1150btus


18.What is the heating value of LP gas? - ANSWER 2500btus


19.How should you check for leaks? - ANSWER Soapy bubbles or
combustible leak detectors


20.Which gas is more volatile, NG OR LP? - ANSWER LP


21.The purpose of a draft hood/draft diverter is_______?
A) To prevent drafts from entering the burner compartment that comes
from the power cent
hoods.
B) To prevent the combustion chamber from overheating, and allowing air to
come down the

, vent pipe into the room.
C) To allow the flue to control the amount of secondary air drawn in instead of
the vent pipe,
and to prevent air from coming back down the vent into the combustion
chamber
D) To allow the vent pipe to control the amount of secondary air drawn into the
combustion
chamber as designed by its height above the hood. - ANSWER C


22.The two primary functions of the flue are____?
A) The remove combustion byproducts and heat from the equipment
B) To create a draft to pull in secondary air and remove the byproducts
form the combustion
chamber
C) To create a draft to keep the burners cool and remove byproducts from
the cooking area
D) To remove the excessive heat to keep the burners, and cooking surface
from overheating - ANSWER B


23.Primary air is the air______?
A) That surrounds the burner
B) That enters the burner though the venture
C) Is the air that is vented through the exhaust system
D) That must always have a pressure greater than the incoming gas
pressure - ANSWER B


Every time a gas fired convection oven shuts off the gas flow to the burners there
is a loud pop.
The oven is rated for and using LP gas. The noise is called_____, and can be
reduced by____ the

Geschreven voor

Instelling
GAS CFESA
Vak
GAS CFESA

Documentinformatie

Geüpload op
11 mei 2026
Aantal pagina's
34
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
DrSammuel

Maak kennis met de verkoper

Seller avatar
DrSammuel TeachmeTutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4
Lid sinds
4 maanden
Aantal volgers
0
Documenten
660
Laatst verkocht
2 weken geleden
Turning Preparation into Achievement.

Welcome to my study resource hub! This account provides high-quality exam papers with clear and detailed elaborations designed to help students fully understand each topic and pass with confidence.

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen