Ohio Fire Alarm Exam Prep
Study online at https://quizlet.com/_gswe4v

1. Where Public Mode audible appliances are installed 15dBA
they shall be ______________ above average ambient
sound level

2. Where audible appliances are installed in mechanical 85dBA
equipment rooms, the average ambient sound level is
_______________

3. An average ambient sound leve greater than 105 dBA
__________ shall require the use of visible notification
appliance

4. Manual fire alarm boxes shall not be mounted less false
than 3-1/2' and not more than 5' above the finished
floor (true or false)

5. All fire detection devices shall be listed or approved for true
the purpose for which they are intended (true or false)

6. A detector should not be recessed in any way unless ture
it has been tested for such a mounting (true or false)

7. Smoke detectors listed or approved exclsively for door True
release service shall not be used for open area protec-
tion (true or false)

8. Manual fire alarm boxes shall not be mounted less true
than 3-1/2' and not more than 4' above the finished
floor (true or false)

9. How far from the doorway shall a manal fire alarm 5' or as close as the AHJ
station be mounted? dictates

10.


, Ohio Fire Alarm Exam Prep
Study online at https://quizlet.com/_gswe4v

What kind of detectors are used for door closer oper- Photoelectric, ionization,
ation? or other listed types

11. When there is more than a(n) ___________ inch depth 24"
partition over a door or double-doors two detectors
must be installed

12. A bimetallic heat detector is an example of spot-type detector
a(n)___________

13. Vane-type flow switches have no longer than _________ 1-1/2 minutes or 90 sec-
to initiate an alarm onds

14. Smoke detectors must be tested every_______ 1 year (annually)

15. Sensitivity in smoke detectors and single & multi- 1 year (annually)
ple-station smoke alarms in other than 1&2 family
dwellings shall be checked within _____ year or years
after installation

16. Type of detector that should be installed six feet away Photoelectric
from a florescent fixture?

17. A spot-type heat detector located on a wall, shall not 12" (between 4in-12 in)
be more than _______ inches from the ceiling

18. A type of smoke detector which uses a small amount ionization detector
of radioactive material is a(n) _____________

19. With a peak ceiling, heat and smoke detectors shall be 3' or 36"
located within _________ of the peak, measured hori-
zontally

20. Smoke detectors shall not be located near _________ Air supply diffusers



, Ohio Fire Alarm Exam Prep
Study online at https://quizlet.com/_gswe4v

21. When beams project more than ______ inches below 18"
the ceiling and are more than 8' on center, each bay
formed by the beams shall be treated as a separated
area for heat detectors

22. When manual fire alarm boxes are used, the distance 200'
between boxes will not be in excess of _________

23. A water flow device should be field adjusted so that an 90 seconds or 1-1/2 min-
alarm is initiated in no more than _____ seconds utes

24. Smoke detectors shall not be located directly in the air supply registers
stream of___________

25. Detectors shall not be installed until after ________ final cleanup of all trades
(unless specified by the
AHJ for construction)

26. A heat detector integrally mounted on a smoke de- 50'
tector shall be listed and approved for not less than
_______ feet

27. Detectors for common return systems should be in- 12"
stalled up to ________ in front or behind openings

28. A line type obscuration smoke detector where the projected beam smoke
light beam is projected across the area to be protected detector
is a _________

29. A device which detects the visible or invisible particles Smoke
of combustion is a ______ detector

30. 42", 48"

Geschreven voor

Instelling
OHIO FIRE ALARM
Vak
OHIO FIRE ALARM

Documentinformatie

Geüpload op
11 mei 2026
Aantal pagina's
18
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Testport Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2223
Lid sinds
1 jaar
Aantal volgers
3
Documenten
3798
Laatst verkocht
10 uur geleden

5.0

998 beoordelingen

5
979
4
14
3
3
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen