A room heater installed in either a sleeping area or public area shall be:
| | | | | | | | | | | | |




A. direct vent only
| | |




B. equipped with a regulator
| | | |




C. equipped with a fan
| | | |




D. equipped with an on / off switch on the wall - CORRECT ANSWER✔✔-B
| | | | | | | | | | | | |




What type of vent must be used when the vent of a wall furnace will be
| | | | | | | | | | | | | | | |


concealed in a partition wall? | | | |




A. B vent
| |




B. L vent
| |




C. BH vent
| |




D. BW vent - CORRECT ANSWER✔✔-D
| | | | |




Single wall vent connectors:
| | |




A. may pass through floors, ceilings or roofs provided a metal thimble is used
| | | | | | | | | | | | |




B. may pass through floors, ceilings or roofs provided the required minimum
| | | | | | | | | | | |


distance from combustible material is maintained
| | | | |




C. may pass through floors, ceilings or roofs provided they are insulated
| | | | | | | | | | |




D. shall not pass through floors, ceilings or roofs - CORRECT ANSWER✔✔-D
| | | | | | | | | | |

,BW vent shall be used only with an approved:
| | | | | | | |




A. decorative appliance
| |




B. down flow furnace
| | |




C. revertible flue boiler
| | |




D. recessed wall furnace - CORRECT ANSWER✔✔-D
| | | | | |




What must be done during the installation of a gas log fireplace?
| | | | | | | | | | |




A. Make sure there is a metal mesh screen in front of the fireplace
| | | | | | | | | | | | |




B. Secure the chimney damper in the open position
| | | | | | | |




C. Install a pressure regulator
| | | |




D. Install a metal chimney liner - CORRECT ANSWER✔✔-B
| | | | | | | |




When can a certified hose be used to connect a construction heater to temporary
| | | | | | | | | | | | |


piping?
|




A. Only if a lever handle shut off valve is installed upstream of the hose
| | | | | | | | | | | | | |




B. Only if the hose is 15 feet long
| | | | | | | |




C. Never - CORRECT ANSWER✔✔-A
| | | |




Which of the following is acceptable when a fireplace insert is installed?
| | | | | | | | | | |




A. A metal chimney linear
| | | |




B. The existing fireplace flue
| | | |




C. BW vent
| |




D. A tile lined fireplace flue? - CORRECT ANSWER✔✔-A
| | | | | | | |

,An unvented infra-red heater can be installed in ________ application
| | | | | | | | | |




A. A warehouse
| |




B. A commercial building
| | | |




C. An industrial building
| | |




D. All of the above - CORRECT ANSWER✔✔-D
| | | | | | |




Dirt pockets are required on:
| | | |




A. Decorative appliances
| |




B. Gas logs
| |




C. Room heaters
| |




D. None of the available choices - CORRECT ANSWER✔✔-D
| | | | | | | |




What diameter and length of a dirt pocket is required when a drop line is 3-inch
| | | | | | | | | | | | | | | |


diameter?
A. 3 inch diameter by 3 inches long
| | | | | | |




B. 1 inch diameter by 3 inches long
| | | | | | |




C. 3/4 inch diameter by 3 inches long
| | | | | | |




D. 2 inch diameter by 3 inches long - CORRECT ANSWER✔✔-D
| | | | | | | | | |




What type of room heater maybe installed in a bathroom?
| | | | | | | | |




A. Natural draft
| |




B. Direct fired
| |




C. Forced draft
| |

, D. Direct vent - CORRECT ANSWER✔✔-D
| | | | |




What safety control protects a steam boiler if the condensate pump fails to return
| | | | | | | | | | | | |


water to the boiler?
| | | |




A. High pressure limit control
| | | |




B. Low pressure limit control
| | | |




C. Flame safeguard control
| | |




D. Low water cut off - CORRECT ANSWER✔✔-D
| | | | | | |




The relief valve for a residential low-pressure hot water boiler system should be?
| | | | | | | | | | | |




A. 14.7 psia
| |




B. 15 psia
| | |




C. 30 psig
| |




D. 30 psia - CORRECT ANSWER✔✔-C
| | | | |




A backflow prevent used in a boiler system should be located in the:
| | | | | | | | | | | |




A. Over flow line connected to the drain
| | | | | | |




B. Return line close to the boiler
| | | | | |




C. 1/4" line connecting the boiler and cushion tank
| | | | | | | |




D. Make up water line to the system - CORRECT ANSWER✔✔-B
| | | | | | | | | |




Automatic chlorinators must be installed: | | | |




A. upstream of the heater
| | | |




B. downstream of the heater
| | | |

Geschreven voor

Instelling
TSSA G2
Vak
TSSA G2

Documentinformatie

Geüpload op
12 mei 2026
Aantal pagina's
117
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$21.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Lectphilip West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
240
Lid sinds
1 jaar
Aantal volgers
6
Documenten
23099
Laatst verkocht
21 uur geleden
WELCOME TO LECTPHILIP, A PLACE WHERE WE UNLOCK YOUR ACADEMIC OPPORTUNITIES

On this page, you find all documents, package deals and flashcards offered by seller lectphilip

4.0

41 beoordelingen

5
20
4
8
3
9
2
2
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen