Questions & Answers (Grade A+)
The bucky slot cover on a fluoroscopic machine is used to protect:
the general public
the pregnant patient
the radiographer
the pediatric patient -
correct answer ✅the radiographer
When radiographing a patient in the Waters position, which
anatomical plane is perpendicular to the plane of the film?
Midsagittal
Glabello-meatal
Acanthomeatal
Orbitomeatal -
correct answer ✅Midsagittal
Which of the following is the correct formula for determining heat
units for a three-phase, twelve-pulse X-ray machine?
,ARRT Mini-Mock Registry Exam
Questions & Answers (Grade A+)
mA x time x kVp x 1.41
mA x kVp x mAs
kVp x mAs x 1.35
kVp x mA x time -
correct answer ✅mA x time x kVp x 1.41
Which of the following may have an effect on patient-exposure
dose?
1. Milliamperage seconds
2. filtration
3. beam restriction
1 and 3 only
2 and 3 only
1, 2, and 3
1 and 2 only -
correct answer ✅1, 2, and 3
Which of the following terms means to draw away from the body?
, ARRT Mini-Mock Registry Exam
Questions & Answers (Grade A+)
flex
abduct
evert
adduct -
correct answer ✅abduct
The medical abbreviation meaning "every hour" is
pc
tid
qh
qid -
correct answer ✅qh
Protective gloves worn during fluoroscopic procedures should be
lined with a minimum lead equivalent of:
1.5mm Pb
0.25mm Pb