Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Florida Air Conditioning Contractors Complete Exam Study Questions with 100% Correct Answers | Brand New Version

Rating
-
Sold
-
Pages
20
Grade
A+
Uploaded on
13-05-2026
Written in
2025/2026

Florida Air Conditioning Contractors Complete Exam Study Questions with 100% Correct Answers | Brand New Version 1. Platform length support limit - ANSWER Each end of a platform 10 feet or more in length shall not exceed its support more than 30 inches. 2. Maximum hanger spacing for ducts - ANSWER The maximum hanger spacing for a duct sized less than 48 inches wide and less than 48 inches high is 5 feet. 3. Safe working load (SWL) - ANSWER A rope with a 20,000-pound capacity and a safety factor of 4 has a safe working load (SWL) of 5 tons.. 4. Slip and drive gauge requirement - ANSWER Slips and drives must not be less two gage(s) lighter than the duct wall nor below 24 gauge. 5. Sheave diameter strength efficiency - ANSWER A 6-inch sheave diameter when using a ¾-inch rope will produce a strength efficiency of 86 percent. 6. Commercial kitchen make-up air - ANSWER The amount of commercial kitchen make-up air supplied to the building from all sources shall be approximately equal to the amount of exhausted air. 7. Motor mounting styles - ANSWER All of the following are motor mounting styles except semi rigid. 8. Shut off valve installation - ANSWER A shut off valve shall be installed on the fuel oil supply line within reach. 9. Recommended superheat setting for low temperature evaporators - ANSWER 5 to 8 °F 10. Part of the thermal expansion valve that fastens the valve to the refrigerant piping - ANSWER valve body 11. Joining method for polyethylene pipe - ANSWER Adhesives and plastic fittings 12. Temperature-rise ratings for greater efficiency of a dry-type transformer - ANSWER 150 °F 13. Minimum Annual Fuel Utilization Efficiency (AFUE) for most furnaces - ANSWER 80 percent 14. Methods of controlling bacteria - ANSWER Encapsulation and electroporation 15. Minimum space between deep-fat fryer and surface flames - ANSWER 6 inches 16. Halide leak detectors detection capability - ANSWER 1 ounce per year 17. Type of eye splice not commonly used by wire rope manufacturers - ANSWER A fold back type 18. Minimum net exhaust flow rate for medium-duty cooking appliance - ANSWER 200 cfm per linear foot of hood length 19. Weight of a 22-gauge galvanized steel sheet - ANSWER 1.1562 pounds per square foot 20. Maximum air infiltration rate for skylights - ANSWER 0.3 cfm/ft2 21. Minimum width of heat seal tape - ANSWER All heat seal tape shall be a minimum width of 2 inch(es). 22. Ladder rung spacing - ANSWER Rungs of portable ladders and fixed ladders shall be spaced not less than 12 inches apart. 23. Face velocity for air coolers - ANSWER Random media air coolers are typically designed so that the wetted pads have a face velocity from 90 to 250 fpm so that the pressure drop remains below 0.1 in wg. 24. Refrigerant system requirement - ANSWER A capture system shall be provided for all systems containing 55 lbs. or more of refrigerant. 25. Discharge position identification - ANSWER The discharge position is identified by all except CCWBADD. 26. Grease duct construction thickness - ANSWER Grease ducts shall be constructed of stainless steel having a minimum thickness of 18 gauge. 27. Maximum temperature for solar systems - ANSWER Solar systems or solar-assisted systems shall be designed, constructed and controlled so that the temperature in the supply system shall not exceed 275°F. 28. Avoidance in duct installation - ANSWER Where electrical, fossil fuel, or solar energy collection heat sources are installed in air ducts, the installation shall avoid the creation of a fire hazard. 29. PPE responsibility - ANSWER The Employer is responsible for requiring of wearing of appropriate PPE in all operations. 30. Laying length of gate valve - ANSWER The laying length of a 2-inch cast iron flanged wedge gate valve with a pressure of 175 psi is 7 ¼ inches. 31. Smallest angle for duct installation - ANSWER The smallest angle he can use is 1 ¼" x 1 ¼" x 3/16". 32. Symptoms of refrigerant shortage - ANSWER Symptoms of a shortage of refrigerant include all of the following except high superheat. 33. Fan belt tension deflection - ANSWER When a fan belt is grasped and checking tension, you should obtain about a ½ inch deflection when finger pressure is applied. 34. Fusible links temperature rating - ANSWER The HVAC system normally operates at 184 degrees. The fusible links shall have a temperature rating of approximately 200 degrees.

Show more Read less
Institution
Florida Air Conditioning Contractors
Course
Florida Air Conditioning Contractors

Content preview

Florida Air Conditioning Contractors Complete
Exam Study Questions with 100% Correct
Answers | Brand New Version

1. Platform length support limit - ANSWER Each end of a platform 10 feet or
more in length shall not exceed its support more than 30 inches.


2. Maximum hanger spacing for ducts - ANSWER The maximum hanger
spacing for a duct sized less than 48 inches wide and less than 48 inches
high is 5 feet.


3. Safe working load (SWL) - ANSWER A rope with a 20,000-pound capacity
and a safety factor of 4 has a safe working load (SWL) of 5 tons..


4. Slip and drive gauge requirement - ANSWER Slips and drives must not be
less two gage(s) lighter than the duct wall nor below 24 gauge.


5. Sheave diameter strength efficiency - ANSWER A 6-inch sheave diameter
when using a ¾-inch rope will produce a strength efficiency of 86 percent.


6. Commercial kitchen make-up air - ANSWER The amount of commercial
kitchen make-up air supplied to the building from all sources shall be
approximately equal to the amount of exhausted air.


7. Motor mounting styles - ANSWER All of the following are motor mounting
styles except semi rigid.

,8. Shut off valve installation - ANSWER A shut off valve shall be installed on
the fuel oil supply line within reach.


9. Recommended superheat setting for low temperature evaporators -
ANSWER 5 to 8 °F


10.Part of the thermal expansion valve that fastens the valve to the refrigerant
piping - ANSWER valve body


11.Joining method for polyethylene pipe - ANSWER Adhesives and plastic
fittings


12.Temperature-rise ratings for greater efficiency of a dry-type transformer -
ANSWER 150 °F


13.Minimum Annual Fuel Utilization Efficiency (AFUE) for most furnaces -
ANSWER 80 percent


14.Methods of controlling bacteria - ANSWER Encapsulation and
electroporation


15.Minimum space between deep-fat fryer and surface flames - ANSWER 6
inches


16.Halide leak detectors detection capability - ANSWER 1 ounce per year


17.Type of eye splice not commonly used by wire rope manufacturers -
ANSWER A fold back type

, 18.Minimum net exhaust flow rate for medium-duty cooking appliance -
ANSWER 200 cfm per linear foot of hood length


19.Weight of a 22-gauge galvanized steel sheet - ANSWER 1.1562 pounds per
square foot


20.Maximum air infiltration rate for skylights - ANSWER 0.3 cfm/ft2


21.Minimum width of heat seal tape - ANSWER All heat seal tape shall be a
minimum width of 2 inch(es).


22.Ladder rung spacing - ANSWER Rungs of portable ladders and fixed
ladders shall be spaced not less than 12 inches apart.


23.Face velocity for air coolers - ANSWER Random media air coolers are
typically designed so that the wetted pads have a face velocity from 90 to
250 fpm so that the pressure drop remains below 0.1 in wg.


24.Refrigerant system requirement - ANSWER A capture system shall be
provided for all systems containing 55 lbs. or more of refrigerant.


25.Discharge position identification - ANSWER The discharge position is
identified by all except CCWBADD.


26.Grease duct construction thickness - ANSWER Grease ducts shall be
constructed of stainless steel having a minimum thickness of 18 gauge.

Written for

Institution
Florida Air Conditioning Contractors
Course
Florida Air Conditioning Contractors

Document information

Uploaded on
May 13, 2026
Number of pages
20
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
DrSammuel

Get to know the seller

Seller avatar
DrSammuel TeachmeTutor
Follow You need to be logged in order to follow users or courses
Sold
4
Member since
4 months
Number of followers
0
Documents
660
Last sold
2 weeks ago
Turning Preparation into Achievement.

Welcome to my study resource hub! This account provides high-quality exam papers with clear and detailed elaborations designed to help students fully understand each topic and pass with confidence.

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions