SPECIAL ENGINEER BOILER EXAM LATEST 2026-2027 ACTUAL
EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED
ANSWERS (100% VERIFIED ANSWERS) |ALREADY GRADED A+|
||PROFESSOR VERIFIED|| ||BRANDNEW!!!||
The purpose of a safety valve on a steam boiler is to: - ANSWER-
To prevent the boiler from exceeding its MAWP
The control designed as a safety back up, should the operating
fail is: - ANSWER-A high limit control
The capacity of a safety valve used on a steam boiler is measure
in: - ANSWER-pounds of steam that can be discharge in one
hour.
How does a pressuretrol attach to the steam space of boiler
control the burner operation? - ANSWER-On pressure decrease -
starts the burner.
What action should an operating engineer take if a defect is
discovered in a boiler requiring repairs not of a routine nature? -
ANSWER-Notify the boiler inspector.
,2|Page
Boiler are considered low pressure when? - ANSWER-Steam
Boiler are not over 15 psi and liquid boiler are not over psi 160
and 250 deg. F
What boiler license required is required for operating a boiler as a
shift engineer in a plant having 3 boiler each 1660 sq. ft. of
heating surface? - ANSWER-Second
The maximum temperature to be carried on a low pressure hot
water boiler is: - ANSWER-Less than 250 f
The popping pressure of a safety relief valve on a low pressure
hot water heating boiler cannot exceed: - ANSWER-160 psi
The bottom blow down line on a steam boiler system is located at
the: - ANSWER-Lowest Point on the waterside of a steam boiler.
For the purpose of rating boiler horsepower for engineer license
classifications only. How many sq. ft. of heating surface shall be
, 3|Page
considered equivalent to one boiler horsepower for conventional
boiler? - ANSWER-10 sq. ft.
What is recommended for boilers that will be out of service a long
time is a possibility of freezing? - ANSWER-A dry lay up.
The rapid burning of fuel oxygen that the results in the release of
heat is called? - ANSWER-Combustion
On a steam boiler what is used to reduce the amount of
movement of the water so the operator can get accurate reading
of the water level in the gauge glass? - ANSWER-Water Column
After repair work is done on the boiler what test is used to check
for leaks? - ANSWER-Hydro static test
How can you tell if the sight / gauge glass isn't working properly? -
ANSWER-Water move up and down slowly