Certification NEWEST {2025-2026}
VERSION EXAMS With
Comprehensive Questions and Well
Elaborated Correct Answers GRADED
A+
Professional Academic Assistance Services
Services Offered
Proctored Exam Assistance
Online Class Management (Full Course Support)
Exam Preparation & Study Materials
Assignments and Coursework Support
Essays and Research Papers
Discussion Posts and Replies
,Which of the following factors can have a negative effect on uterine blood flow?
a. Hypertension
b. Epidural
c. Hemorrhage
d. Diabetes
e. All of the above - correct ans:e. All of the above
How does the fetus compensate for decreased maternal circulating volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement. - correct ans:b. Increases cardiac output by
increasing it's heart rate.
Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
d. No change - correct ans:a. A decrease in the heart rate
What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels
e. A & C
f. A & B
g. C & D - correct ans:g. C & D
,The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect to the FHR
baseline?
a. Increases baseline
b. Decreases baseline - correct ans:b. Decreases baseline
T/F: Oxygen exchange in the placenta takes place in the intervillous space. - correct ans:True
T/F: The parasympathetic nervous system is a cardioaccelerator. - correct ans:False
T/F: Baroreceptors are stretch receptors which respond to increases or decreases in blood pressure. -
correct ans:True
T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart rate: the ultrasound
transducer and the fetal spiral electrode. - correct ans:True
T/F: Variability can be determined with the fetoscope. - correct ans:False
T/F: Because the ultrasound transducer and toco transducer are sealed units, they can be dipped in
warm water to make cleaning easier. - correct ans:False
T/F: The most common artifact with the ultrasound transducer system for fetal heart rate is increased
variability. - correct ans:True
T/F: All fetal monitors contain a logic system designed to reject artifact. - correct ans:True
T/F: The monitor should always be tested before starting a tracing, either external or internal mode and
labeled a test. - correct ans:True
T/F: The paper speed on the fetal monitor should always be set at 1cm/min. - correct ans:False
, T/F: Both internal and external monitoring methods are equally accurate means of obtaining the fetal
heart rate and contraction patterns. - correct ans:False
T/F: The external toco is usually placed over the uterine fundus to pick up contractions. - correct
ans:True
T/F: The external toco gives measurable uterine pressure. - correct ans:False
T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown origin is present. -
correct ans:False
T/F: The ultrasound transducer is usually placed on the side of the uterus over the baby's back, as the
fetal heart is heard best there. - correct ans:True
T/F: The spiral electrode is used to more accurately determine the frequency, duration, and intensity of
uterine contractions. - correct ans:False
T/F: The heart rate from a well-applied fetal spiral electrode can only be fetal, not maternal. - correct
ans:False
T/F: The intrauterine catheter is used to pick up the fetal heart rate. - correct ans:False
T/F: The internal spiral electrode may pick up the maternal heart rate if the baby has died. - correct
ans:True
T/F: Fetal arrhythmias can be seen on both internal and external monitor tracings. - correct ans:True
T/F: Variability and periodic changes can be detected with both internal and external monitoring. -
correct ans:True
T/F: Variable decelerations are a result of cord compression. - correct ans:True