Comprehensive Resource To Help You Ace 2026-2027
Exams Includes Frequently Tested Questions With
ELABORATED 100% Correct COMPLETE SOLUTIONS
Guaranteed Pass First Attempt!! Current Update!!
Instant Download Pdf
1. Basic Types of Sprinkler Systems - Correct Answer: Wet-Pipe, Dry-Pipe,
Deluge, Preaction
2. Standpipes - Correct Answer: Class 1 and 3 the size of the riser must be
4" for buildings less than 100'. 6" pipe for buildings over 100'.
3. Class II Stand Pipe Riser - Correct Answer: 2" for buildings under 50'
4. Current Practice is to locate Standpipes - Correct Answer: So that any
part of the floor is within 130' of Stand Pipe
5. Class I and III Standpipes require ______ FDC Connections - Correct
Answer: 1 or More
6. Foam extinguishes a fire by - Correct Answer: Smothering, Separating,
Cooling, Suppressing
,7. Class A Extinguishers - Correct Answer: Ordinary Combustibles
8. Class B Extinguishers - Correct Answer: Flammable Liquids
9. Class C Extinguishers - Correct Answer: Electrical Equipment
10.Class D Extinguishers - Correct Answer: Combustible Metals
11.Class K Extinguishers - Correct Answer: Cooking, Greases, Fats, Oils
12.Maximum travel Distance to a Class A Extinguisher - Correct Answer: 75
Feet
13.Maximum travel Distance to a Class K Extinguisher - Correct Answer: 30
Feet
14.FACP - Correct Answer: Fire Alarm Control Panel (The Brain)
15.Backup Power for a Fire Alarm must activate within how many seconds after
main power loss? - Correct Answer: 30 Seconds
16.Detector - Correct Answer: Detects
,17.Alarm - Correct Answer: Notifies
18.Smoke Inhalation accounts for - Correct Answer: 65% of deaths in a fire
19.Photoelectric Detectors - Correct Answer: Used in Large Common Areas
20.According to NFPA 72 the pull station should be mounted on the wall -
Correct Answer: So no part is less than 3 1/2 feet from the floor or a
maximum of 4 1/2 feet
21.Travel Distance to Manual Pull Stations - Correct Answer: 200 Feet
22.Pull Stations should also be placed - Correct Answer: Within 5 Feet of
every exit so the occupants can activate as they leave.
23.Manual Pull Stations can be - Correct Answer: Single Action or Double
Action
24.Proprietary Alarm - Correct Answer: Used to protect large complexes or
several sites with one receiving point.
25.High-rise structures, commercial buildings, groups of commonly owned
buildings, industrial buildings.
, 26.Uncontained Fires should not be allowed - Correct Answer: Within 50
feet of a structure
27.Grounds around a Burn Pile or Bonfire should be - Correct Answer:
Cleared of Vegetation or cut to less than 3 inches
28.Three Primary Storage Method - Correct Answer: Pallet, Rack, Solid
29.Materials stored inside may not be - Correct Answer: stacked closer
than 2 feet from the ceiling without automatic sprinklers or 18 inches of
those with.
30.Tents must have how much spacing between stake lines - Correct
Answer: 10 Feet
31.Pyrotechnics and Flames are - Correct Answer: Prohibited in any tents
or temporary structures
32.Vegetation must be cleared - Correct Answer: Inside a tent and 10 feet
around
33.Where combustible materials such as paper clippings, wood shavings, or
textile fibers a radius of - Correct Answer: 35 Feet must be cleared
before welding