VERIFIED AND 100% VERIFIED ANSWERS ALREADY
GRADED A+
When may compressed air be used to clean dust from equipment
Only when the pressure is reduced to 50 psi maximum and personal
protective equipment is on place
Only when the pressure is reduced to 30 psi or less and personal
protective equipment is provided
Never
Only when the pressure is reduced to less than 45 psi - ANS... -Only
when the pressure is reduced to 30 psi or less and personal protective
equipment is provided
Which of the following documents are primarily used by the contractor
and architect to monitor quality?
Construction drawings
Contract addenda
Meeting Minutes
Submittals, shop drawings, and samples - ANS... -Submittals, shop
drawings, and samples
In order to protect the owner and contractor from lien filings, what
document is provided by a subcontractor in exchange for final payment?
Partial lien release
Unconditional lien release
Conditional lien release
Notice of completion - ANS... -unconditional lien release
What does a lien waiver release the owner from?
Paying the contractor for extra services
Paying twice for services or materials
The right to claim a lien
,Needing to file a notice of commencement - ANS... -paying twice for
services or materials
A renovation project is to begin on a pre-1978 housing project. It will
require that more than 2 square feet of painting surface be removed and
disturbed. What should the contractor do prior to beginning?
-Distribute an EPA pamphlet entitled "Protect your family from lead in
your home" to the property owner or adult occupant
-Submit a lead abatement notice to the EPA within 5 days of starting the
project
-Notify the owner and tenants of the project start
Inform the local health department of the project schedule - ANS... -
Distribute an EPA pamphlet entitled " Protect your family from lead in
your home" to the property owner or adult occupant
Which of the following is not a concern for a precast concrete contractor
during a reconstruction meeting?
Field layout and verification
Developing an erection plan
Maintaining anticipated overhead and profit margins
Determining site conditions - ANS... -Maintaining anticipated overhead
and profit margins
The international building code states that the minimum thickness of
plywood species group | that may be used for subfloor joists spaced 16
inches on center is :
1/2
3/8
3/4
7/8 - ANS... -1/2
When a contract requires the contractor to indemnify the owner for any
liability the owner may incur under he should:
Have the contract reviewed by an attorney
Ask for a liquidated damages clause
, Ask for a cost plus type contract
Obtain higher performance bond - ANS... -Have the contract reviewed
by an attorney
Which of the following is included in a company's general overhead
costs?
Performance Bonds
Withholding Taxes
Costs for equipment purchase and rentals
The company's administrative expenses - ANS... -The company's
administrative expenses
What is the purpose of ventilating unconditioned spaces?
To control moisture
Dehumidification
Control oxygen levels
Temperature Control - ANS... -To control moisture
Oxygen Cylinders shall be stored:
Separate from fuel gas cylinders a minimum of 10 ft
Separate from fuel gas cylinders a minimum of 20 ft
In a centrally located air tight closet
In a storage locker - ANS... -Separate from fuel gas cylinders a
minimum of 20 ft
What size diameter anchor bolts should open web joists have at each
end?
1 1/2"
2 1/2"
3 1/2"
4 1/2" - ANS... -2 1/2"
When should duplex nails be used?
When building concrete forms