Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Journeyman Pipefitter Test | QUESTIONS AND ANSWERS | LATEST UPDATE

Beoordeling
-
Verkocht
-
Pagina's
16
Cijfer
A+
Geüpload op
27-05-2026
Geschreven in
2025/2026

Journeyman Pipefitter Test | QUESTIONS AND ANSWERS | LATEST UPDATE

Instelling
Vak

Voorbeeld van de inhoud

Journeyman Pipefitter Test | QUESTIONS AND
ANSWERS | LATEST UPDATE

Save




Practice questions for this set


Learn 1/7 Study with Learn




Cross fitting



Choose an answer



1 The discharge outlet of a safety valve must



What type of fitting must be placed in the water piping connection at every right angle
2
to facilitate cleaning and inspection of a water column of low water cutoff



The return pipe connections of each boiler supplying a gravity return steam heating
3 system shall be so arranged as to form a loop so that the water in each boiler cannot
be forced out below the safe water level. This loop is most commonly known as



The appropriate valve application for a boiler blow off valve on a high pressure boiler
4
is a

, Don't know?




Terms in this set (92)



The discharge outlet of a safety Be as short and straight as possible and arranged
valve must to avoid stress on the pipe


An altitude gauge is required on a 20
hot water supply boiler when the
altitude is more than how many feet


The most appropriate valve Meter valve
application for a surface blow down
system would be what valve


a safety valve over 3" and over 15 flanged or welded
psig shall have what type of inlet
connection?


The appropriate valve application Y- Type Globe Valve
for a boiler blow off valve on a high
pressure boiler is a


Which form of Safety Valve mounting To an internal pipe in the boiler
is not permissible in the Heating
Boiler Code?


Which is true regarding a boiler water Reduces the turbulence of the water to give a more
column accurate reading in the gauge glass


Two Low Water cut-offs are required The Boiler has pumped condensate returns and has
on a steam heating boiler when an input over 200,000 BTU

, When piping low water fuel cutoff Lowest visible part of the water gauge glass
devices to a boiler, the devices must
be piped to what height in relation to
the level of the gauge glass?


A 3/4 blow off may be used on a 100'
high pressure boiler if the boiler
heating surface is less than how
many square feet on the heating
surface


Which device shall cause a safety Auxiliary low water cut-off with a manual reset
shutdown (lockout) requiring a
manual reset


The required boiler feedwater stop The boiler and the check valve
valve on a high pressure boiler is
located between what


The return pipe connections of each The Hartford steam loop
boiler supplying a gravity return
steam heating system shall be so
arranged as to form a loop so that
the water in each boiler cannot be
forced out below the safe water
level. This loop is most commonly
known as


When are steam valves required Each boiler outlet


When is a Pipefitter license required Anything over 700,000 BTU (522) CMR
and under what law

Geschreven voor

Vak

Documentinformatie

Geüpload op
27 mei 2026
Aantal pagina's
16
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
profEve

Maak kennis met de verkoper

Seller avatar
profEve Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
8
Lid sinds
6 maanden
Aantal volgers
0
Documenten
1299
Laatst verkocht
1 maand geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen