Answers | Already Graded A+
2 Main types of valves found in water supply distribution systems -
ANSWER ✔✔Indicating and non-indicating
or Isolation and control
To prevent a pressurized hose from injuring a firefighter, a gate valve
should be placed in the line with a hole drilled in the gate
A. 1/8 inch B. 1/4 inch C. 1/2 inch D. 3/4 inch - ANSWER ✔✔B. 1/4
inch
If the pressure gauge on a wet-pipe sprinkler system reads "no
pressure," chances are the system has been shut off at the:
,A. main control valve.
B. main drain valve.
C. fire department connection.
D. gate valve. - ANSWER ✔✔A. main control valve.
A condition that will encourage a fire to start or will increase the extent or
severity of a fire is called a _____ hazard
A. common B. target C. fire D. special - ANSWER ✔✔C. fire
Which statement regarding residential sprinklers is incorrect?
A. They are smaller versions of wet or dry-pipe sprinkler systems.
B. The water supply is combined with the domestic system
C. The use of plastic pipe is allowed
D. They are designed to control the level of fire involvement such that
residents can escape - ANSWER ✔✔D. They are designed to control
the level of fire involvement such that residents can escape
The four fundamental components of a modern water system are:
A. source, mains, feeders, and risers.
B. primary, secondary, standpipes, and subscriber connections.
C. pipes, valves, hydrants, and pumps.
,D. source, means of moving, treatment plant, and distribution system -
ANSWER ✔✔D. source, means of moving, treatment plant, and
distribution system
Automatic sprinkler systems are designed to control 70% of the fires
inside the structure with
A. five or fewer heads.
B. a minimum of ten sprinkler heads.
C. no more than one sprinkler head.
D. every sprinkler head in the structure. - ANSWER ✔✔A. five or
fewer heads.
The purpose of the fire department connection to a sprinkler system is
to:
A. supplement the water supply while maintaining operational pressure
B. provide water, since most systems are dependent on the fire
department for water supply.
C. boost the water to upper stories, since most water pressure is not
sufficient to supply water above the sixth floor
D. add water pressure to the system because normal water distribution
is inadequate when loss than three heads are
COPYRIGHT©PROFFKERRYMARTIN 2025/2026. YEAR PUBLISHED 2026. COMPANY REGISTRATION NUMBER: 619652435. TERMS OF USE.
PRIVACY STATEMENT. ALL RIGHTS RESERVED
, activated. - ANSWER ✔✔A. supplement the water supply while
maintaining operational pressure
Which of the following sprinkler system components is used to limit
water flow to one direction?
A. OS&Y valve B. Check valve C. Control valve D. Butterfly valve -
ANSWER ✔✔B. Check valve
When shutting clown a wet-pipe sprinkler system, one should first turn
off the main water control valve and
A. disable the alarm check valve.
B. open the exhauster to drain the system.
C. drain the system.
D. close all riser indicating valves. - ANSWER ✔✔C. drain the
system.
Chemicals, dusts, and metals are considered to be _____ hazards.
A. life safety B. fuel C target D heat source - ANSWER ✔✔B. fuel
What two factors contribute to determining which risk class to assign a
certain building area?
A. Direction and density of pedestrian traffic flow