International
Residential
International
Residential
Code
Residential
(IRC)
CodeMaster
(IRC)
CodeMaster
Set
(IRC)
–Master
Set
Complete
–Set
Complete
Residential
– Complete
Residential
Building
Residential
Building
Codes,
Building
Codes,
Standards,
Codes,
Standards,
andStandards,
Contractor
and Contractor
and
Exam
Contractor
Study
ExamGuide.pdf
Study
ExamGuide.pdf
Study Guide.pdf
International
Residential Code
(IRC) Master Set –
Complete
Residential
Building Codes,
Standards, and
Contractor Exam
Study Guide
International
International
Residential
International
Residential
Code
Residential
(IRC)
CodeMaster
(IRC)
CodeMaster
Set
(IRC)
–Master
Set
Complete
–Set
Complete
Residential
– Complete
Residential
Building
Residential
Building
Codes,
Building
Codes,
Standards,
Codes,
Standards,
andStandards,
Contractor
and Contractor
and
Exam
Contractor
Study
ExamGuide.pdf
Study
ExamGuide.pdf
Study Guide.pdf
,International Residential Code Master Set.pdf International Residential Code Master Set.pdf International Residential Code Master Set.pdf
IRC
Water-resistant gypsum backing board shall be permitted to be used on ceilings
where the framing spacing does not exceed ___ inches on center for 1/2 inch thick
gypsum board
Choose an answer
1 16 Inch 2 18 Inch
3 24 Inch 4 12 Inch
Don't know?
Terms in this set (194)
IRC 120 Sq feet
Permit not required for a one story detached accessory
structure ( Tool Shed ) provided the floor area des not
exceed
IRC 4 Feet
Permit not required for retaining walls that are not over ? feet
in height unless supporting a surcharge
IRC Complete
Final inspection shall be made after permitted work is ___ and
prior to ___ Occupancy
International Residential Code Master Set.pdf International Residential Code Master Set.pdf International Residential Code Master Set.pdf
,International Residential Code Master Set.pdf International Residential Code Master Set.pdf International Residential Code Master Set.pdf
IRC Completion
Building permit or copy shall be kept on site of work untill ?
of the project
IRC Load Bearing Wall
A wall supporting any vertical load in addition to its own
weight is a ___ wall
IRC 110 Degree F
Hot water is water at a temperture greater than or equal to ___
IRC Accessabile
Signifies access that requires the removal of an access panel
or similar removable obstruction
IRC 7 3/4 Inch
On stairways the maximum riser height shall be
IRC 36 Inches
Stairways shall not be less than ___ inches in clear width at all
pionts above the permitted handrail height and below the
required headroom height
IRC 3 feet x 3 feet
A Minimum ___ x ___ foot landing shall be provided:
1) At the top and bottom of ramps
2) Where the doors open onto ramps
3) Where ramps change direction
International Residential Code Master Set.pdf International Residential Code Master Set.pdf International Residential Code Master Set.pdf
, International Residential Code Master Set.pdf International Residential Code Master Set.pdf International Residential Code Master Set.pdf
IRC 36 Inches
Every landing will have a minimum dimension of ___ inches
measured in durection of travel
IRC Landing
There shall be a floor or ___ at the top and bottom of each
stairway
IRC 44 Inches
Where openings are provided as a means of escape and
rescue they shall have a sill height of not more than ___ inches
above floor
IRC 1/2 Inch
Garage shall be seperated from the residence and its attic
area by not less than ___ inch gypsum board or equivalent
applied to the garage side
IRC Not
Openings from a private garage directly into a room used for
sleeping purposes shall ___ be permitted
IRC Hazardous
Glazing in swinging doors ( except jalousies ) shall be
considered a ___ location
IRC 6 Feet
Showers and bathtubs with installed shower heads shall be
finished with a nonabsorbent surface , that shall extend to a
height of not less than ? feet above the floor
International Residential Code Master Set.pdf International Residential Code Master Set.pdf International Residential Code Master Set.pdf