All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire
guards must have a current ✔Correct Answer-Certificate of Fitnesss95
The Certificate of Fitness holders95 ✔Correct Answer-must regulate the pressure and flow of
oxygen and natural gas to each torch.
if the torch operator for jewelry manufacture involves ✔Correct Answer-any oxygen with any
fuel gas containers, the operator must be a C of F holder.
A Certificate of Fitness Holder must keep his or her certificate ✔Correct Answer-on their
person or otherwise readily available for inspection by any representative of the fire
Department
The easiest way to extinguish a fire caused by a leak is to ✔Correct Answer-close the shutoff
valve
Permits issued by the FDNY are required to conduct the following hot work: ✔Correct
Answer-storing, using or handling oxygen and a flammable gas, storing, using or handling any
flammable gas (e.g. LPG or CNG or acetylene) in excess of
400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF.
For LPG, 400 SCF is ✔Correct Answer-approximately 47 lbs
the number of LPG containers for the storage, use, handling or transportation, requiring a
permit ✔Correct Answer-14.1 oz = 54 cont.
16.4 oz = 46 cont.
20 lbs = 3 cont.
33.5 lbs = 2 cont.
40 lbs = 2 cont.
100 lbs = 1 cont.
Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater
than 8.7 SCF ✔Correct Answer-must NOT stored, handled, or used indoors in the following
occupancies (as defined in the Building code): residential occupancies, factory and industrial
occupancies; educational occupancies; institutional occupancies, except as the commissioner
may authorize by rule.
Site-specific permit ✔Correct Answer-may be a permanent permit or a temporary permit.
Permanent permits are valid for 12 months only
, A city-wide permit is valid ✔Correct Answer-up to 30 days
Permits shall be ✔Correct Answer-readily available on the premise for inspection by Fire
Department representatives.
Hot work authorization should be issued by the responsible person, and it ✔Correct Answer-
must be available for inspection by any representative of the department during the
performance of the work, and for 48 hours after the work is complete
FDNY permits ✔Correct Answer-will be posted in a central location and recorded in a log book
to assist in the coordination of construction related activities.
CNG ✔Correct Answer-Compressed Natural Gas.
For Citywide hot work operations, the Owner of the premises must be notified in writing at least
_____ hours in advance prior to work beginning. ✔Correct Answer-48
A class A fire extinguisher fights fires from ✔Correct Answer-Paper
How old must a candidate be in order to earn a Certificate of Fitness? ✔Correct Answer-18
Years Old
What type of fire is a Class B fire extinguisher used on? ✔Correct Answer-Oil
Examples of combustibles include ✔Correct Answer-Newspaper
An example of a flammable material would be ✔Correct Answer-Gasoline
Fire extinguishers must be inspected once every ✔Correct Answer-Month
A work area should be ✔Correct Answer-Well Ventilated
A type C fire involves ✔Correct Answer-Live electrical equipment
Automatic sprinkler heads should be ✔Correct Answer-covered by a damp cloth and removed
after hot work
A permit is required for storing a flammable gas in excess of ✔Correct Answer-400 scf
Acetylene burns at ✔Correct Answer-3000 degrees Fahrenheit
It is dangerous to use fuel gas at pressures above ✔Correct Answer-15 psi