HESI RADIOLOGY EXIT EXAM VERSION 1 LATEST ACTUAL
EXAM WITH COMPLETE QUESTIONS AND CORRECT
DETAILED ANSWERS (100% VERIFIED ANSWERS)
|ALREADY GRADED A+| ||PROFESSOR VERIFIED||
||BRANDNEW!!!||
Which change should be made when performing an abdomen radiograph on a
patient with ascites? ......ANSWER......Raise exposure factors.
Which system can store images? ......ANSWER......Picture archival and
communication system (PACS).
What is the result if pixel bit depth is decreased? ......ANSWER......Contrast
resolution is decreased.
Prior to performing a posteroanterior (PA) chest projection with automatic
exposure control (AEC), the radiographer discovers that the patient has had a
right total pneumonectomy. Which technical consideration should be
considered? ......ANSWER......Selecting only the detector on the left side.
Without changing any other factors, which effect is caused by decreasing the
field size from 14X17 inches to 8X10 inches? ......ANSWER......Decrease in the
amount of scatter radiation within the part.
pg. 1
,2|Page
How often should lead aprons be evaluated to determine if cracks or holes are
present? ......ANSWER......Annually.
An increase in which factor will improve spatial resolution?
......ANSWER......Source to image receptor distance (SID).
What is the most likely reason for the increase in quantum noise on a computed
radiography (CR) image? ......ANSWER......Lower than required milliampere-
seconds (mAs).
Which information in the patient history should prompt the radiographer to
decide against using automatic exposure controls when taking a chest x-ray?
......ANSWER......Emphysema.
Which statement is true regarding exposure indicator and the evaluation of
digital images? ......ANSWER......Exposure indicator must be reviewed with every
image and must fall within the manufacturer's acceptable range.
Which digital communication network is used to store patient billing
information? ......ANSWER......HIS.
Which digital post-processing results in a black background surrounding the
original collimated edges? ......ANSWER......Shuttering.
Which device temporarily stores an electric charge? ......ANSWER......Capacitor.
What are recommended uses of the digital annotation tool? (Select the four that
apply.) ......ANSWER......Entering technical factors
pg. 2
,3|Page
Indicating date or time of the exam
Labeling central ray (CR) projection
Indicating radiographer performing the exam
How does an increase in noise affect the quality of a digital image?
......ANSWER......Contrast is decreased.
Which pathologic condition requires a reduction in exposure factors to produce
an acceptable image? ......ANSWER......Emphysema.
The radiographer is using automatic brightness control during fluoroscopy. What
change in patient exposure should the radiographer expect as the patient size
increases? ......ANSWER......Increase in exposure.
Which calculation is used to determine grid ratio? ......ANSWER......Height of the
lead strips divided by the width of the interspace material.
Which is the most likely cause of a histogram error? ......ANSWER......Selection of
an incorrect exam from the look-up table.
Picture archiving and communication system (PACS) networks are capable of
performing which functions? (Select the two that apply.)
......ANSWER......Transmitting diagnostic images to remote work stations.
Downloading images from different imaging modalities.
Who judges radiographic images for quality? (Select the four that apply.)
......ANSWER......Radiographers
pg. 3
, 4|Page
Ordering physicians
Radiologists
Quality control technologists
How can magnification of the heart be reduced when performing a chest x-ray?
......ANSWER......Use a 72-inch source-image-receptor-distance (SID).
What is the function of a rectifier? ......ANSWER......Convert alternating current
to pulsating direct current.
Which change in technical factors is most likely to result in decreased exposure
to the image receptor (IR)? ......ANSWER......Increased grid ratio
Which technique produces a 2 milliroentgens (mR) exposure to an image
receptor plate if 70 kilovolts peak (kVp) at 25 milliampere-seconds (mAs)
produces 1.6 mR? ......ANSWER......70 kVp at 31.25 mAs
Consider this anteroposterior (AP) mobile chest image. What will improve the
photographic quality of this image? ......ANSWER......Using a grid
On which system does hospital staff input new orders for radiologic
examinations? ......ANSWER......Hospital information system.
Which part of the x-ray circuit is controlled by adjusting the milliamperage (mA)
setting on the operating console for the purpose of producing the heat
necessary for thermionic emission? ......ANSWER......Filament circuit
pg. 4