Content preview

ARDMS SPI EXAM LATEST 2026-2027
UPDATE COMPREHENSIVE QUESTIONS
AND CORRECT ANSWERS| ALREADY
GRADED A+/PASSED 100%
Example of nonspecular reflector - correct answer-red blood cells



What happens to spatial pulse length when frequency increases? - correct answer-decreases



Axial resolution is dependent on? - correct answer-wavelength



Lateral resolution is dependent on? - correct answer-beam diameter



Where does the beam of an unfocused transducer diverge? - correct answer-Fraunhofer zone



Reverberation artifacts are a result of - correct answer-two or more strong reflecting surfaces



True/False: Grating lobes are essential for the proper operation of a linear phased array. -
correct answer-False



True/False: Electronically steered scanners always produce higher resolution images than do mechanicall
y steered scanners. - correct answer-False



True/False: An annular array scanner uses mechanical beam steering. - correct answer-True



True/False: AKlinear sequenced array cannot be dynamically focused. - correct answer-False



registration or B-mode alignment - correct answer-
Which AIUM test object function utilizes all the groups of wires in the AIUM 100 mm test object?

,axial resolution - correct answer-
Which AIUM test object function utilizes the A group of wires in the AIUM 100 mm test object?



lateral resolution - correct answer-
Which AIUM test object function utilizes the B group of wires in the AIUM 100 mm test object?



dead zone - correct answer-
Which AIUM test object function utilizes the D group of wires in the AIUM 100 mm test object?



depth calibration - correct answer-
Which AIUM test object function utilizes the C or E groups of wires in the AIUM 100 mm test object?



What happens to axial resolution when spatial pulse length is decreased? - correct answer-improves



How much will a 3.5 MHz pulse be attenuated after passing through 2 cm of soft tissue? -
correct answer-3.5 dB



Propagation speed errors result in - correct answer-improper axial position



Enhancement is caused by - correct answer-weakly attenuatingKstructures



The Doppler shift frequency is - correct answer-directly proportional to the velocity of the reflector



The number of frames per second necessary for a real-time image to be flicker free is - correct answer-
more than 15



True/False: The SPTA intensity will always be larger than the SATA intensity. - correct answer-True



The intensity of the ultrasound beam is usually greater at the focal zone because of - correct answer-
the smaller beam diameter

,If the amplitude is doubled, the intensity is - correct answer-quadrupled



The attenuation for soft tissue is - correct answer-increased with tissue thickness



The acoustic impedance of the matching layer - correct answer-
can be chosen to improve transmission into the body



True/False: In a pulse-echo system, the quality factor should be made as large as possible. -
correct answer-False



True/False: The beam diameter is constant in the near zone. - correct answer-False



The operating frequency is dependent on - correct answer-thickness of the crystal



The period of an ultrasound wave is - correct answer-the time of one wavelength



The dynamic range of a system is - correct answer-
the ratio of smallest to largest power level that the system can handle



True/False: The intensity of an ultrasonic beam can be measured with radiation force balance. -
correct answer-True



Increasing the pulse repetition period - correct answer-
increases the maximum depth that can be imaged



Ultrasound bioeffects - correct answer-are not confirmed below 100 mW/cm² SPTA



True/False: No refraction can occur at an interface if the media impedances are equal. - correct answer-
False



True/False: Smaller transducers always produce smaller beam diameters. - correct answer-False

, True/False: The ultrasound beam profile can be measured with a hydrophone. - correct answer-True



True/False: The pulsed-
Doppler system yields better depth resolution than the continuous wave (CW) system. - correct answer-
True



True/False: The gray-
scale display was made possible when digital scan convertersKreplaced analog scan converters. -
correct answer-False



True/False: Videotape recorders operatingKat 30 frames per second cannot be used with mechanical real
-time units because the fram rate is too slow. - correct answer-False



True/False: Linear phased array scanners need no form of mechanical focusing because focusing is perfo
rmed electronically. - correct answer-False



True/False: The fram rate of real-
time scanners depends on the number of lines used to form the image. - correct answer-True



True/False: It is not possible to steer an annular phased array electronically. - correct answer-True



True/False: The near zone length should be kept as short as possible. - correct answer-False



What percentage of intensity of an ultrasound pulse incident on an interface of 0.25 and 0.75 rayls is refl
ected? - correct answer-25%



Axial resolution can be improved by using - correct answer-higher frequency transducers



When particle motion of a medium is parallel to the direction of a wave propagation, the wave being tra
nsmitted is called a - correct answer-longitudinal wave

Written for

Institution
Ardms
Course
Ardms

Document information

Uploaded on
June 6, 2026
Number of pages
56
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Articulatewrites EXAMS
Follow You need to be logged in order to follow users or courses
Sold
19
Member since
1 year
Number of followers
1
Documents
4063
Last sold
5 days ago
A+ Testbank , solution manual all are found in Articulate writes

• "Welcome to Articulate writes Welcome to creative writers, your go-to source for high-quality test banks , solution manuals and quizlet at an affordable prices that you can afford ,thankyou for visiting our page

3.0

5 reviews

5
1
4
1
3
1
2
1
1
1

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions