Voorbeeld van de inhoud

MRSO Exam Question and Answer 2026 |
Complete Study Guide with Practice
Questions | A+ Verified
Which of the following can be potential safety concerns to a patient in the static
magnetic field?
A. Electrically conductive materials
B. Ferrous objects
C. Magnetic objects
D. All of the choices. -✓✓D. All of the choices

An object that retains its magnetic field when exiting the static magnetic field is call
what?
A. Paramagnetic
B. Diamagnetic
C. Ferromagnetic
D. Superparamagnetic -✓✓C. Ferromagnetic

What direction is the vector of a permanent MR unit?
A. Horizontal
B. Vertical
C. Diagonal
D. Variable -✓✓B. Vertical

What separates a superconducting MR unit from a resistive MR unit?
A. Cryogen
B. Coils of wires
C. Permanent magnets
D. none of the choices -✓✓A. Cryogen

The increasing strength of magnetism as we move closer to the MR unit is called what?
A. Ferromagnetism
B. Spatial magnetic gradient field
C. Vector
D. B0 -✓✓B. Spatial magnetic gradient field

What is responsible for attracting ferrous objects into the MR unit?
A. Spatial magnetic gradient fields
B. Strong uniform magnetic fields
C. Gradient coils
D. Radiofrequency system -✓✓A. Spatial magnetic gradient fields

If we placed a small ferrous object at isocenter, what would we expect to happen?

,A. The object would experience no attraction.
B. The object would immediately be attracted to the bore.
C. The object would levitate.
D. The object would be repulsed by the unit. -✓✓A. The object would experience no
attraction.

Rotational force will be the strongest at what location?
A. Isocenter
B. Outside the MR room
C. At the gantry opening
D. At the 5 gauss line -✓✓A. Isocenter

Passive shielding uses which of the following?
A. Coils of wires with electrical current running through them.
B. Magnetically conductive materials
C. Plastic
D. Wood -✓✓B. Magnetically conductive materials

How can we reduce risks associated with Lenz's force?
A. No risks are associated with Lenz's force.
B. Use a cold compress to reduce heating.
C. Move as quickly as possible to get the patient out of the scanner quickly.
D. Advance patient into the scanner slowly. -✓✓D. Advance Patient into the scanner
slowly.

An implant has a deflection of 23 degrees. In terms of static magnetic fields, is it safe for
this patient to have an MRI?
A. Yes
B. Must call the manufacture to determine conditions.
C. No
D. Not enough information. -✓✓A. Yes

Which of the following stainless steels are non-ferrous?
A. Ferritic
B. Martensitic
C. Austenitic
D. All are ferrous -✓✓C. Austenitic

It is not safe for a patient to cross over the 5 gauss line. How many millitesla is this?
A. 0.5mT
B. 5mT
C. 50mT
D. 0.005mT -✓✓A. 0.5mT

, A patient is placed in a magnetic field that changes over a distance from the MR unit.
What do we need in order to meet the manufacture limits if a patient with an implant will
be safe from the threats associated with the static magnetic field prior to their MRI.
A. Spatial gradient map.
B. Compression
C. The MRSO sole approval.
D. All of the choices. -✓✓A. Spatial gradient map

The spatial gradient of 1.5 T MR unit, not the maximum spatial gradient has a lower
spatial gradient than a 3.0 T MR unit.
A. True
B. False -✓✓B. False

Which of the following are documented biological effects associated with the static
magnetic field?
A. Magnetophosphenes
B. Magnetohydrodynamic Effect
C. Headaches
D. Difficulty breathing -✓✓A. Magnetophosphenes, B. Magnetohydrodynamic Effect
and C. Headaches.

What is the purpose of the time-varying gradient magnetic field?
A. To produce resonance in our hydrogen nuclei
B. To change the precessional speeds of hydrogen
C. To produce net magnetism
D. To form an image. -✓✓B. To change the precessional speeds of hydrogen.

The effect of the time-varying gradient is greatest where?
A. Periphery of the patient.
B. At isocenter
C. At the 5-gauss line.
D. Outside the MR room. -✓✓A. Periphery of the patient.

The X coil will produce what plane of image?
A. Coronal images
B. Axial images
C. Sagittal images
D. Oblique images -✓✓C. Sagittal images

Slew rate is measured in what?
A. T/m/s
B. mT
C. Seconds
D. Watts/kg -✓✓A. T/m/s

Geschreven voor

Instelling
MRSO
Vak
MRSO

Documentinformatie

Geüpload op
8 juni 2026
Aantal pagina's
22
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
PACKPASS Harvard University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
38
Lid sinds
5 maanden
Aantal volgers
0
Documenten
5719
Laatst verkocht
1 dag geleden
Pass Package Academy

As a tutor, I provide accurate, reliable, and up-to-date study materials to support students in their exam preparation and assignments. My focus is on high-quality resources such as summaries, nursing exam guides, and test banks designed to help you study with confidence and achieve better results. After your purchase, your feedback is highly important, please take a moment to leave a review. Reviews help maintain quality, guide other students, and improve future study materials. Your support and honest reviews are greatly appreciated and make a real difference. Thank you for trusting my services. Wishing you success and good luck in your studies.

Lees meer Lees minder
4.0

3 beoordelingen

5
2
4
0
3
0
2
1
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen