Accessible hazard area correct answers Area made hazardous by the flame effect that is normally
accessible to a person without the deliberate use of an additional means of access that is not
normally in place
Storage area correct answers where fuel or materials are held prior to use to movment to holding
area
Direct ignition correct answers automatic or manual ignition system that ignites fuel without a
pilot
Fail-safe correct answers a state or an attribute of a system such that every single point failure in
the system results in all controlling parts of the system with the ability to do harm to humans,
animals, or equipment being disconnected from all sources of power and stored energy at the
primary disconnect point
Fire correct answers after arm, it is the control system functions that result in the deliberate
release of fuel for ignition
Flame effect burner correct answers A burner designed to produce specific sizes and
configurations of flames for flame effects
Flame effect material correct answers A flammable material that is used as fuel to create a flame
Flame effect safety controller correct answers A control system that is part of a flame effect
appliance that is used to prove that the source of ignition is present (flame safeguard control)
Group II flame effect correct answers An individual or group flame effect designed fro
unattended operation that is temporarily or permanently installed outside any sructure (eternal
monument flame)
Group III flame effect correct answers An attended, temporarily installed flame effect for a
specific production with limited operation and fixed time for removal
Group IV flame effect correct answers Large or group flame effect that is permanently installed
inside or outside any structure desined for unattended operation WITHOUT a main show
supervisory control system
Group V flame effect correct answers A large individual or group flame effect that is temporarily
or permanently installed inside or outside any structure and is designed for intermittent or
continuous operation under the supervision of a main show control system, but without full-time
supervision by a technition
Group VI flame effect correct answers A large individual or group flame effect that is
temporarily or permanently installed outside or inside any structure and is designed for
, intermittent operation under the supervision of a main show control system and a technical
director, with cast members in close proximity to the effect at the time of operation
Group VII flame effect correct answers an individual flame effect that can be tomprarily or
permanently installed inside or outside any structure that, due to its unique operating
requirements, does not fit into any other classification
Permanent installation correct answers more than 180 days
temporary installation correct answers duration of 180 days or less within a 12-month period in a
single venue
Flame effect plan correct answers document that is used to convery to the AHJ the information
needed to evaluate the flame effect for the purpose of applying for a permit
Primary safety control correct answers A control with a sensor that is directly responsive to the
ignition device attributes necessary for the safe operation of the effect
proven pilot correct answers a pilot flame supervised by a primary safety ctonrol
Safety critical correct answers the failure of a device component, system, or mechanism, which
results in a situation that is immediately dangerous to life, health, or property
Supervisory cock correct answers a manually actuated valve with two double-pole, double throw
switches that prove the valve position
accumulator charge valve correct answers valve used to control the flow of fuel into an
accumulator
effect valve correct answers the last fuel shutoff valve before the flame effect burner
proof-of-closure valve correct answers the safety shutoff valve equipped with an interlock switch
that is actuated only when the valve is fully closed
safety shutoff valve correct answers fast closing valve that automatically and completely shuts
off the fuel supply in response to a normal or safety shutdown
amount of fuel held in holding areas correct answers amount used in 1 day or more if the AHJ
allows it
holding area must be secured or supervised by an attendant trained in emergency response
procedures
use permit correct answers -only the number and type of flame effects described in flame effect
plan