2026 FULL QUESTIONS AND SOLUTIONS
GRADED A+
◍ TIA-607-C.
Answer: Which standard is the primary standard for recommendations and
requirements related to installing a telecommunication bonding
infrastructure
◍ work area.
Answer: A building space where te occupants interact with
telecommunications terminal equipment (an individual office or cubicle,
printer/copier room.
◍ Omni, Semi, Radiant, Directional.
Answer: What are the 4 types of antenna's
◍ TIA-606.
Answer: Which ANS/TIA standard would you refer to locate labeling
requirements and recommendations for the components of a structured
cabling system.
◍ Class 3.
Answer: Multiple buildings on the campus
◍ Provides stability for a pole when extra ground footing surface is needed, it
is a platform that keeps it from sinking in the ground..
Answer: Plank bracing platforms
◍ `Half-tap module.
Answer: Allows a second cable to be spliced into the middle of an existing
cable.
,◍ Moment strength.
Answer: Value of movement in newton meters or equivalent in pound force
feet is equal to the transverse load in newtons or equivalent in pound force
feet multiplied by the distance in meters from the load point to the point
considered value of moment.
◍ Series 11.
Answer: What type of coaxial cable is used in video back-bone distribution
◍ Used in most soils except rock or hardpan, 2 or 4 way..
Answer: Expansion anchor
◍ Bonding the shield to the_____ will reduce noise level in the
telecommunications cable..
Answer: MGN
◍ _________ A pole that inclines from a true vertical position, This is done to
make sure the top pole will be in line..
Answer: Raked Pole
◍ Class 4.
Answer: Multiple sites with multiple buildings
◍ Uses a solid polymer that insulates each conducting wire ad is color coded
and more resistant to electrical surges and more tolerant to handle than
PE-39 has 6 to 3000 Pairs.
Answer: PE-89
◍ Important set of deliverables.
Answer: Design documents
◍ What splicing module is preferred in free breathing space in aerial
applications.
Answer: Encapsulated
◍ Simidirectional.
Answer: What antenna requires the use of a stud finder
, ◍ T568A T568B.
Answer: What are the 2 standards compliant wiring schemes for 8p8c
modular connectors
◍ (VIRT) Verify, isolate, repair, test.
Answer: What are the steps for trouble shooting a cabling system
◍ Both end walls and one side wall.
Answer: J-3
◍ Straight module.
Answer: Joins the end of a binder group from two separate cables using one
25 pair module
◍ Direct buried cables collects ground strikes with a distance determined by
soil resistance typically?.
Answer: 6.6' to 19.7'
◍ What determines the maximum permissible end to end system attenuation in
a given fiber link?.
Answer: Average transmitter power and receiver sensitivity
◍ Used to fasten cables at a corner..
Answer: Corner or pull
◍ Bolts usally have a ____ dia..
Answer: 5/8"
◍ _____ or less doesn't interfere with aircraft authorities.
Answer: 200'
◍ Crosstalk.
Answer: Is decreased by pairs twists, cable lay, shielding, and physical pair
separation. Its values are typically a negative decibel value. closer to 0 more
problems.
◍ Suitable for use at locations where anchor rod with permentally frozen soil
for 1/2 of rod length.
Answer: Concrete anchor